Bosch MX934i Скачать руководство пользователя страница 2

Page 2

© 2011 Bosch Security Systems, Inc.

MX934i Installation Instructions

- The following chart will help you set the correct Vertical

Angle based on the mounting height, mirror type, and
desired range.

6.5 (2.0)

7.5 (2.3)

8.5 (2.6)

Mounting

Height

Broad

Barrier

Long Range

-12°

-14°

-6°

-8°

-8°

-6°

-5°

-12°

-8°

-7°

-9°

-3°

-5°

-5°

Height and desired Range listed in feet (meters)

20 (6) 35 (10) 20 (6) 35 (10) 40 (12) 70 (20)

-10°

-10°

-6°

-4°

- The angle adjust markings are on the mirror. Slide the mirror

forward or back until the angle hash marks are in-line with
the markers on each side of the frame.

-16

-8

Mirror

0

+2

4.0

Wiring

Only apply power after all connections have been made
and inspected.

•  Connect wiring as shown.

NOTE:

Do not coil excess wiring inside unit.

• Seal the Wire Entrance

 

using the foam plug provided.

Terminal Descriptions

1 (-) and 2 (+):

Connect to the AUX Power of the control panel.

This connection is only required if LED operation (other than
during the walk test) is required. Use no smaller than #22 AWG
(0.8 mm) wire between the detector and the control panel.

3 (B-) and 4 (B+):

  Connect to the Multiplex Bus of the control

panel. Use no smaller than #22 AWG (0.8 mm) wire between
the detector and the control panel.

5.0

Configuring Detector

5.1

LED Operation Jumper

OFF

ON

H

I

S

LED OFF

LED ON

ON

:

Allows the LED to operate when activated by alarm.

OFF

: The LED will not operate on alarm.

If the detector is powered by the MUX Bus only,  the LED
is for  Walk Test purposes only. 

 Disable the LED when

Walk Testing is complete.  To disable the LED, place the
jumper in the OFF position.  

If the detector has AUX

Power supplied

, the LED operation may be left ON during

normal use.

5.2

Sensitivity Mode

OFF

ON

H

I

S

HIGH

INTERMEDIATE

STANDARD

Standard Sensitivity

:  Recommended setting for maximum false

alarm immunity. Tolerates environment extremes on this setting.
Not recommended for Long Range or Barrier type patterns. The
detector is shipped in Standard Sensitivity mode.

Intermediate Sensitivity

:  Recommended setting for any location

where an intruder is expected to cover only a small portion of the
protected area. Tolerates normal environments on this setting.
This setting will improve your intruder catch performance.

High Sensitivity

:  Fast response to intruder signals. For use in

quiet environments where thermal and illumination transients
are not anticipated.

6.0

Address Switch Settings

• Set the address switch settings (see page 3) before connecting

the MX934i to the multiplex bus.

IMPORTANT

No two devices may be set to the same address. Having
two or more units set to the same address may prevent
fault detection or  cause  multiplex bus failure.

1 2

3

4 5

6

7

8

O

N

- + B- B+

1 2

3

4 5

6

7

8

O

N

• You can find the Address Switch Settings using the chart on

page 3, or by calculating the decimal number of the address.

                                    

Binary Switch Values (Point 17 shown)

O
N

1

2

3

4

5

6

7

8

128 64 32 16

8

4

2

1

IMPORTANT

Zone (Point) Addresses 001 through 008 are reserved for
"on board" points on the DS7400(Xi) Series control panels.

Do not set any multiplex devices for Addresses 001-008 when

using a DS7400(Xi) Series control panel.

1 2 3

4 5

6

7 8

O

N

MUX

BUS

AUX

POWER

-

IN

+

IN

B-

IN

B+

IN

- + B- B+

2

1

3 4

Содержание MX934i

Страница 1: ... Product Date Codes For Product Date Code information refer to the Bosch Security Systems Inc Web site at http www boschsecurity com datecodes 2 0 Control Panel Programming Refer to the multiplex programming section of your Control Panel Reference Guide for information on programming multiplex zones for this device 3 0 Mounting Avoid Direct or reflected sunlight Moisture Moving objects Hot or cold...

Страница 2: ...complete To disable the LED place the jumper in the OFF position If the detector has AUX Power supplied the LED operation may be left ON during normal use 5 2 Sensitivity Mode OFF ON H I S HIGH INTERMEDIATE STANDARD Standard Sensitivity Recommended setting for maximum false alarm immunity Tolerates environment extremes on this setting Not recommended for Long Range or Barrier type patterns The det...

Страница 3: ... 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 1 2 3 4 5 6 7 8 ZONE POINT ADDRESS SWITCH NUMBER SWITCH ON CLOSED 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 1 2 3...

Страница 4: ...t on a regular basis assures an alarm output prior to arming the system 9 0 Coverage Patterns Refer to the mirror module and pattern drawings for masking information Before masking be sure the chosen mirror surface is the correct one When removing masking remember many adhesives will either destroy the mirror s surface or leave residue behind to reduce coverage performance This product is factory ...

Отзывы: