13
Installation
13.1
Safety
Danger! Electric voltage! Operations in the vi‐
cinity of live parts are extremely dangerous.
WARNING
Work required on the electric system may only be carried out by skilled elec‐
tricians. Tools for electricians (VDE tools) are absolutely necessary.
Prior to commencing work:
1. Isolate (even auxiliary circuits).
2. Protect the system or plant against restart.
3. Ensure de-energization.
4. Ground and short-circuit.
5. Cover or shield any adjacent live parts.
Before starting to work, check with an appropriate measuring device whether
parts of the system are still under residual voltage (e.g. caused by capacitors,
etc.). If yes, wait until these parts have discharged.
Injuries due to improper handling during
transport of motors!
CAUTION
Do only use suitable lifting devices (e.g. lifting sling belts, eyebolts, chain sus‐
pension ...).
Use protective equipment and personal protective clothing (gloves, safety
shoes, ...).
Never walk under hanging loads.
Carry out all work steps with particular care. This minimizes the risk of acci‐
dents and damage.
DOK-MOTOR*-MSK*EXGIIK3-PR09-EN-P
Bosch Rexroth AG
151/175
Synchronous Servomotors MSK For Potentially Explosive Areas
Installation
Содержание MSK030B NSNN Series
Страница 110: ...Bosch Rexroth AG DOK MOTOR MSK EXGIIK3 PR09 EN P 108 175 Synchronous Servomotors MSK For Potentially Explosive Areas ...
Страница 142: ...Bosch Rexroth AG DOK MOTOR MSK EXGIIK3 PR09 EN P 140 175 Synchronous Servomotors MSK For Potentially Explosive Areas ...
Страница 146: ...Bosch Rexroth AG DOK MOTOR MSK EXGIIK3 PR09 EN P 144 175 Synchronous Servomotors MSK For Potentially Explosive Areas ...
Страница 152: ...Bosch Rexroth AG DOK MOTOR MSK EXGIIK3 PR09 EN P 150 175 Synchronous Servomotors MSK For Potentially Explosive Areas ...
Страница 166: ...Bosch Rexroth AG DOK MOTOR MSK EXGIIK3 PR09 EN P 164 175 Synchronous Servomotors MSK For Potentially Explosive Areas ...
Страница 172: ...Bosch Rexroth AG DOK MOTOR MSK EXGIIK3 PR09 EN P 170 175 Synchronous Servomotors MSK For Potentially Explosive Areas ...
Страница 174: ...Bosch Rexroth AG DOK MOTOR MSK EXGIIK3 PR09 EN P 172 175 Synchronous Servomotors MSK For Potentially Explosive Areas ...