Switch mounting arrangement MKK/MKR-040-NN-3
Proximity sensor
Mechanical switches
Fig� 10:
Installing the magnetic sensor (MKK/MKR-040-NN-3)
Fig� 11:
Installing the magnetic field sensor MKK/MKR-040-NN-3
Fig� 12:
Proximity sensors and mechanical switches MKK/MKR-040-NN-3
MKK
MKR
Magnetic sensor with M8x1 plug, switch mounting plate and cable holder
1.
Insert sensor mount (7b) into the top slot in the frame, position it approximately and secure it with two set
screws (11).
2.
Insert the sensor (7a) into the top (MKK) or bottom (MKR) slot in the sensor mount and secure it by turning the
clamping screw (9). If necessary, install the cable holder (7c) into the top slot.
Magnetic field sensor (6) and mounting channel (5)
f
A mounting channel is needed to fasten the magnetic field sensors and cable guides.
This is suspended in the upper slot on the linear module and secured with set screws (
11
).
f
Insert sensor (
6
) into the top (MKK) or bottom (MKR) T-slot of the mounting channel and secure it with a set
screw (
12
).
MKK
MKR
6
11
6
11
MKK
MKR
6
11
6
11
0,4
+0,2
Proximity sensors and mechanical switches
X
Assembly
!
6.5.10 / 6.5.11
2,5
+0,2
6
5
12
7a
7a
7a
7a
7d
7a
7b
7c
9