35 / 60
MKE Synchronous Servomotors
Cleaning and servicing
Bosch Rexroth AG
R911414374, Edition 01
•
Do not do the grinding procedure in haz-
ardous ambience.
•
Ensure that keys are protected against ejec-
tion.
Enable the safety devices and monitoring sys-
tems of the machine.
Commissioning
Once all requirements are met, proceed as fol-
lows:
•
Commission the drive system according
to the instructions of the corresponding
product documentation. The respective
information can be found in the functional
description of the drive controllers.
•
Record all measures taken in the commis-
sioning log.
Observe the general and technology-dependend
safety instructions in this documentation.
For commissioning of the controllers and control
systems, additional steps may be required. The
inspection of the functioning and performance
of the systems is not object of these Operating
Instructions; instead, it is carried out within the
framework of the commissioning of the machine
as a whole. Comply with the information and
instructions of the machine manufacturer.
9.4
Operation
CAUTION
Explosion hazard!
Do not install the amplifier (drive controller) in a
hazardous area.
CAUTION
Explosion hazard!
Do not operate the motor in potentially explosive
atmospheres if any mounting screws or covers
are removed. Do not remove any screws or
covers while the motor is in a potentially explo-
sive area.
CAUTION
Explosion hazard!
Do not operate the motor outside the parameters
shown in the motor performance curves
During operation, keep the ambient and opera-
tion conditions and technical data specified in
the operating instruction and project planning
manual.
Checks during operation:
•
Pay attention to exceptional noise.
•
Pay attention to increased vibrations.
•
Check the motor for cleanliness.
•
Check the monitoring devices and diag-
nostic / error messages of the controllers.
Decommission the drive when deviations from
normal operation exist. For further procedure
refer to
Chapter 13 “Eliminate malfunction ”
10
Maintenance
10.1 Cleaning and servicing
WARNING
Operations in the vicinity of live parts are
extremely dangerous.
−
Work required on the electric system may
only be carried out by skilled electricians.
Tools for electricians (VDE tools) are abso-
lutely necessary.
−
Isolate (even auxiliary circuits).
−
Secure against reactivation.
−
Ensure de-energization.
−
Ground and short-circuit.
−
Cover or shield any adjacent live parts.
Maint
enance