background image

 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 

ManDown Sensor 

  

User Manual 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Document 953.64c

 

 

Содержание ManDown Sensor

Страница 1: ...ManDown Sensor User Manual Document 953 64c ...

Страница 2: ......

Страница 3: ...16 D 70499 Stuttgart Germany Phone 0711 3653 1000 Fax 0711 811 5125 294 Haus Service Ruf de bosch com www bosch sicherheitsprodukte de Bosch Security Systems Ltd Broadwater Park North Orbital Road Denham UB9 5HN United Kingdom Phone 01895 878088 Fax 01895 878089 uk securitysystems bosch com www boschsecurity co uk Bosch Security Systems France Atlantic 361 361 avenue du Général de Gaulle F 92147 C...

Страница 4: ...cial alarm systems 6 4 Operating 6 4 1 Starting the sensor 6 4 2 Turning off the sensor 6 4 3 Detection mode 7 4 4 Repeating the alarm 7 4 5 Deactivating the help call button and the pre alarm 7 5 Programming the ManDown Sensor 8 6 Maintenance 8 6 1 Safety instructions 8 6 2 Storage 8 6 3 Replacing the battery 9 7 Technical Specifications 10 8 Certification 11 ...

Страница 5: ... social alarm call center through the telephone line or with a NurseCall system 2 Description The ManDown Sensor can be delivered with an operational frequency of 434 MHz or 869 MHz It is equipped with a LED indicator that will flash every ten seconds to show that the sensor is active This LED indicator will flash green if the battery is ok or red if the battery is low Pushing the central red butt...

Страница 6: ...rm that the sensor is active Notice No help call transmission will take place during this operation 4 2 Turning off the sensor Press the button for about five seconds A beeping sound is emitted during two seconds During these two seconds release the button and press it a second time The sensor is then turned off This last step will be confirmed by a slow beeping sound It is always possible to turn...

Страница 7: ...ensor comes back to a vertical position or if the help call button is pressed This pre alarm may be suppressed by making a solder bridge See Fig 2 Interior view of a ManDown Sensor 4 4 Repeating the alarm After a fall as long as the sensor detects a horizontal position the alarm will repeat itself after an average period of time of two minutes and thirty seconds 4 5 Deactivating the help call butt...

Страница 8: ...by an identical or equivalent type Dispose of the used batteries at an appropriate recycling facility Although battery replacement may be done by non specialized person nel the manufacturer recommends that it should be performed by your local dealer Caution The ManDown Sensor contains highly sensitive electronic components It should always be opened in an ESD Electro Static Discharge pro tected en...

Страница 9: ...he ManDown Sensor Carefully remove the compression foam as well as the used battery Replace the new battery ensure that it is in the correct position Carefully place the compression foam as shown in Fig 4 Opening the ManDown Sensor Close the case with the four screws Notice To avoid deteriorating the inserts do not force the screwing VARTA battery 3V CR1 2AA Fig 4 Opening the ManDown Sensor Compre...

Страница 10: ...seconds of detection followed by 30 seconds of signal before automatic activation Battery VARTA 3V CR1 2AA or equivalent Lithium 3 0V diam 14 5mm x 25mm Consumption 5 µA if the ManDown Sensor is deactivated 13 µA if the ManDown Sensor is on stand by Battery lifetime from six months to two years depending on operation and the number of detections performed Type of plastic ABS Cycolac GPM5500S white...

Страница 11: ...ManDown Sensor User Manual 953 64c Bosch Security Systems Page 11 8 Certification ...

Страница 12: ...ManDown Sensor User Manual 953 64c Bosch Security Systems Page 12 ...

Страница 13: ...ManDown Sensor User Manual 953 64c Bosch Security Systems Page 13 ...

Страница 14: ......