background image

LTC 9385 Series | 

Instruction Manual

Installation

EN

| 11

Bosch Security Systems | January 26, 2005

Recommended Maximum Cable Lengths

Models

Wire Size

Distance

mm

2

AWG

meters

feet

-1 (115 VAC)

1.5

16

1000

3280

2.5

14

1600

5250

4

12

2500

8200

-2 (24 VAC)

0.5

22

10

30

0.5

20

15

50

1

18

25

80

1.5

16

40

120

2.5

14

70

210

-4 (230 VAC)

1.5

16

4000

13000

2.5

14

6400

21000

4

12

10000

32800

1. Use the liquid-tight fitting on the left of the

housing to route the power supply cord into the
housing.

2. Allow enough cord for connection to the

terminal block; approximately, 130mm (5in.).
Strip no less than 6mm (0.24in.) and no more
than 8mm (0.31in.) of insulation away from the
wires making sure not to nick the wires.

3. A screw/terminal lug is provided for securing a

safety ground. To attach the safety grounding
wire of the power cord (green 115volt,
green/yellow 230volt), first unscrew the terminal
lug and strip and crimp the grounding wire into
the lug. Next, reattach the terminal lug to the
rail assembly using the M4 x 10 screw and lock
washer provided. See FIGURE 8.

FIGURE 8  Securing the Ground Wire

4. Connect both the line and neutral wires of the

power cord to the terminal block. Make sure
the line and neutral wires are connected to the
correct positions on the terminal block that are
across from the appropriate colored wire. See
FIGURE 9.

FIGURE 9  Attaching Line and Neutral Wires

5. Pull any excess cord through the liquid-tight

fitting and tighten the flex fitting to 8.5N-m to
9.0N-m (75in. lb to 80in. lb). This torque rating
is approximately 1 to 1 1/2 turns past the point
that the fitting starts to grip the cord. Failure to
do so will result in water damage to all
electronic parts. Use a tie wrap (included) to
provide strain relief on the power cord at the
exit point (inside the unit).

Securely tighten all fittings to ensure a liquid-
tight seal. Not doing so could damage the
camera, the housing, or both.

5.8.2 Camera Power Connections

LTC 9385/60 Housings

These housings are to be connected to 115VAC, and
are designed for use where site power is 115volts. The
LTC 9385/60 housings should only be used with 
115volt cameras. The integral heater/defogger 
requires 115volts. The housing is shipped with the
heater/defogger connected to the terminal block.

Installing a 115 volt camera 

into the LTC 9385/60

housing simply requires the camera's line cord to be
plugged into the NEMA 5-15R receptacle provided.
See FIGURE 10.

Содержание LTC 9385 Series

Страница 1: ...Instruction Manual EN Outdoor Housings LTC 9385 Series ...

Страница 2: ...ical shock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from b...

Страница 3: ...ould be taken to keep from touching power lines or circuits as this contact might be fatal U S A models only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack mount Product 1 Ventilation This unit should not be placed in a built in installation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The e...

Страница 4: ...tzer sollte sich ausführlich über Anweisungen für die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Precauciones de Seguridad Atención la instalación la debe realizar únicamente personal cualificado de conformidad con el National Electric Code o las normas aplicables en su país Desconexión de la alimentación Las unidades con o sin interruptores de encendido apagad...

Страница 5: ...prodotto Ciò comporta un potenziale rischio di scosse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Medidas de Segurança Atenção a instalação deve ser executada apenas por técnicos qualificados da assistência de acordo com o código eléctrico nacional ou os códigos locais aplicáveis Corte ...

Страница 6: ...losure Rating 7 5 0 INSTALLATION 7 5 1 Model Designation 7 5 2 Tools Required 8 5 3 Hardware Required 8 5 4 Cable Requirements 8 5 5 Disassembly and Mounting 8 5 6 Camera Lens Installation 9 5 7 Camera Lens Wiring 10 5 8 Plug Insertion 10 5 9 Video Coax Connection 12 5 10 Lens Wiring 13 5 11 Camera Lens Orientation 13 5 12 Camera Lens Adjustment 13 5 13 Final Assembly 14 6 0 EXPLODED VIEW 16 7 0 P...

Страница 7: ...e no moving parts in this unit Regularly scheduled maintenance will help prolong the operational life of this unit Clean the viewing window as needed with a mild nonabrasive detergent in water and a soft cloth 4 0 DESCRIPTION The LTC 9385 Series of environmental housings are attractive aluminum enclosures designed for outdoor CCD camera installations 4 1 Enclosure Rating 4 1 1 NEMA 3R and IP54 The...

Страница 8: ... 6Ω 1000ft RG 11 U Cable Impedence 75Ω Agency Rating UL Environmental Outdoor rated Temperature Rating 80 C 176 F Sources Belden 9259 Belden 9238 Input Power Cord North American Cable Type SJTOW A Rated Cable Size Outside diameter between 4 3mm and 11 9mm 0 170in and 0 470in Cable Shape Round Conductors 3 conductor version and 2 conductor version Agency Rating UL C S A UL VW 1 Environmental Outdoo...

Страница 9: ...y Fixed Lens Cameras Position the camera lens so that the lens is positioned over the heater but not past it Secure the camera to the rail assembly with the 1 4 20 x 3 8in BHC screw a nylon bushing and a 0 4mm 0 016in plastic spacer Place the nylon bushing over the screw and slide both between the rails through the front cut out section Slide the spacer over the screw so it is positioned in betwee...

Страница 10: ...les The NPT wire grip is removed and replaced with the PG version FIGURE 6 Liquid tight Fitting Assembly 5 8 Plug Insertion If no lens control or feed through wiring will be used install the 3 8in NPT plug provided Remove the liquid tight fitting and insert the plug in the small bottom center 3 8in NPT hole Use a 8mm or a 5 16in hex wrench to tighten securely Failure to do so will result in water ...

Страница 11: ... and neutral wires of the power cord to the terminal block Make sure the line and neutral wires are connected to the correct positions on the terminal block that are across from the appropriate colored wire See FIGURE 9 FIGURE 9 Attaching Line and Neutral Wires 5 Pull any excess cord through the liquid tight fitting and tighten the flex fitting to 8 5N m to 9 0N m 75in lb to 80in lb This torque ra...

Страница 12: ...ing on the rear end of the base assembly The fitting will accept cables with diameters from 4 6mm 0 181in to 7 9mm 0 312in See FIGURE 11 2 Attach a BNC connector to the coax and connect it to the camera Pull any excess cable through the liquid tight fitting and tighten the flex fitting to 4 0N m to 4 5N m 35in lb to 40in lb This torque rating is approximately 1 to 1 1 2 turns past the point that t...

Страница 13: ...ra the housing or both FIGURE 12 Lens Control Cable Wiring If using a pan tilt with a feed through cable insert the camera lens function cable in through the right fitting at the rear of the cradle Wire the functions as described above or as needed 5 11 Camera Lens Orientation A unique feature of the LTC 9385 Series housing is the ability to rotate the mounting base 360º around the rail assembly S...

Страница 14: ...ollows 1 If the housing assembly is not already removed from the base assembly do so now see the Disassembly and Mounting section at the beginning of these instructions 2 Obtain a rubber pull seal from the hardware kit Part Number 315 2569 001 An extra pull seal is also provided See FIGURE 15 FIGURE 15 Pull Seal 3 Insert the long end of the pull seal into the breather hole starting from the front ...

Страница 15: ...nd cap and o ring Make sure the o ring is not pinched The safety cable can be routed between the cover and the base See FIGURE 19 FIGURE 19 Replacing the Cover 3 Align the cover holes with the base assembly holes and replace the two M4 screws and washers This secures the cover onto the rest of the housing NOTE Make sure the breather hole is located at the bottom of the housing If it is not remove ...

Страница 16: ...ty Part Description 115VAC Heater Bracket Assembly Kit 315 2809 001 9 1 115VAC Heater Bracket Assembly 1 M3 x 20 Screw 2 Rivet 5 32in x 0 415in 24VAC Heater Bracket Assembly Kit 315 2810 001 9 1 24VAC Heater Bracket Assembly 1 M3 x 20 Screw 2 Rivet 5 32in x 0 415in 230VAC Heater Bracket Assembly Kit 315 2811 001 9 1 230VAC Heater Bracket Assembly 1 M3 x 20 Screw 2 Rivet 5 32in x 0 415in Two Eye Ca...

Отзывы: