background image

EN

| 8

LTC 9384 Series | 

Instruction Manual

Installation

Maximum Camera/Lens Size: 

LTC 9384/xx: 
Accepts cameras up to 64W x 54H mm (2.5 x 2.1in.),
lenses up to 67W x 75H mm (2.6 x 2.9in.), and
camera/lens combinations up to 292mm (11.5in.).

LTC 9384/20NT: 
Accepts cameras up to 64W x 54H mm (2.5 x 2.1in.),
lenses up to 67W x 75H mm (2.6 x 2.9in.), and
camera/lens combinations up to 355mm (14.0in.).

5.2

Tools Required

Flat blade screwdriver

Phillips head screwdriver

5⁄32in. (or 4mm) hex wrench

5⁄16in. (or 8mm) hex wrench

Adjustable wrench

Wire cutter/stripper/crimper tool

5.3

Cable Requirements

5.4

Cradle Removal

1. Remove the cradle from the housing by

lowering the retaining screw completely on the
bottom rear of the housing. 

2. Remove the cradle assembly by pushing gently

on the metal part of front cap and
simultaneously grasping the rear handle and
pulling the cradle assembly out of the housing.
Be sure to keep the edges of the endcaps clean
and free of scratches (see FIGURE 1).

FIGURE 1  Removing the Cradle Assembly

Video Transmission (Coaxial)

Cable Type

RG-59/U (Runs < 1000ft)
RG-11/U (Runs < 2000ft)

Cable Size

Outside diameter between 4.6mm
(0.181in.) and 7.9mm (0.312in.)

Cable Shape

Round

Shield

93% Braided Copper Shield

Center Conductor

Stranded Copper Center

DC Resistance

15

/1000ft (RG-59/U)

6

/1000ft (RG-11/U)

Cable Impedence

75

Agency Rating

UL

Environmental

Outdoor rated

Temperature Rating

80 °C (176 °F)

Sources

Belden 9259
Belden 9238

Input Power Cord - North American

Cable Type

SJTOW-A Rated

Cable Size

Outside diameter between 4.3mm
(0.170in.) and 11.9mm (0.470in.)

Cable Shape

Round

Conductors

3 conductor version and 
2 conductor version

Agency Rating

UL/C.S.A., UL VW-1

Environmental

Outdoor rated

Temperature Rating

105 °C (221 °F)

Voltage Rating

300 V

Sources

Belden 19506
Belden 19509
Northwire 573939

Input Power Cord - European

Cable Type

H05RN-F3G0.75 and
H05RN-F3G1.00

Cable Size

Outside diameter between 4.3mm
(0.170in.) and 11.9mm (0.470in.)

Cable Shape

Round

Conductors

3 conductor version and 
2 conductor version

Agency Rating

VDE

Environmental

Outdoor rated

Sources

Olflex 1600252
Olflex 1600253

Lens Control Cable

Cable Type

Jacketed Multiconductor Cable

Cable Size

Outside Diameter between 4.3mm
(0.170in.) and 11.9mm (0.470in.)

Cable Shape

Round

Shield

Overall shielding

Conductors

Stranded 20 to 16 AWG wire

No. of Conductors

4 and 8

Conductor Insulation

Color coded

Sources

Belden 9552
Belden 9554

Retention Screw

Bosch Security Systems | September 1, 2004

Содержание LTC 9384 Series

Страница 1: ...Instruction Manual EN Outdoor Camera Housings LTC 9384 Series ...

Страница 2: ...l shock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from batt...

Страница 3: ...d be taken to keep from touching power lines or circuits as this contact might be fatal U S A models only refer to the National Electrical Code Article 820 regarding installation of CATV systems For Rack mount Product 1 Ventilation This unit should not be placed in a built in installation or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to The equi...

Страница 4: ...r sollte sich ausführlich über Anweisungen für die Bedienung und Instandhaltung Wartung in den begleitenden Unterlagen informieren Precauciones de Seguridad Atención la instalación la debe realizar únicamente personal cualificado de conformidad con el National Electric Code o las normas aplicables en su país Desconexión de la alimentación Las unidades con o sin interruptores de encendido apagado r...

Страница 5: ...dotto Ciò comporta un potenziale rischio di scosse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Medidas de Segurança Atenção a instalação deve ser executada apenas por técnicos qualificados da assistência de acordo com o código eléctrico nacional ou os códigos locais aplicáveis Corte de ...

Страница 6: ...2 SERVICE 7 3 CARE AND MAINTENANCE 7 4 DESCRIPTION 7 4 1 Enclosure Rating 7 5 INSTALLATION 7 5 1 Model Designation 7 5 2 Tools Required 8 5 3 Cable Requirements 8 5 4 Cradle Removal 8 5 5 Camera Lens Installation 9 5 6 Camera Lense Wiring 9 5 7 Video Coax Connection 12 5 8 Lens Wiring 12 5 9 Final Assembly 12 6 EXPLODED VIEW 14 7 PARTS LIST 14 ...

Страница 7: ...ditional information see www boschsecuritysystems com 3 CARE AND MAINTENANCE Clean the viewing window as needed with a mild nonabrasive detergent in water and a soft cloth 4 DESCRIPTION The LTC 9384 Series of environmental housings are attractive aluminum enclosures designed for outdoor CCD camera installations 4 1 Enclosure Rating 4 1 1 NEMA 3R and IP54 The LTC 9384 Series Housings include a brea...

Страница 8: ...mm 0 181in and 7 9mm 0 312in Cable Shape Round Shield 93 Braided Copper Shield Center Conductor Stranded Copper Center DC Resistance 15Ω 1000ft RG 59 U 6Ω 1000ft RG 11 U Cable Impedence 75Ω Agency Rating UL Environmental Outdoor rated Temperature Rating 80 C 176 F Sources Belden 9259 Belden 9238 Input Power Cord North American Cable Type SJTOW A Rated Cable Size Outside diameter between 4 3mm 0 17...

Страница 9: ...ear of the cradle are preinstalled to a specified torque to prevent entrance of water Do not remove or loosen these parts The two large fittings are supplied with seal glands for cables with diameters from 4 3mm to 11 9mm 0 17in to 0 47in The small fitting will accept cables with diameters from 4 6mm to 7 9mm 0 181in to 0 312in see FIGURE 3 Securely tighten all fittings to ensure a liquid tight se...

Страница 10: ...luded to provide strain relief on the power cord at the exit point inside the unit Securely tighten all fittings to ensure a liquid tight seal Failure to do so could allow water to enter the housing and damage the camera and lens Select the appropriate wiring instructions from this section depending on which Housing is being used 5 6 4 LTC 9384 60 Housings The LTC 9384 60 Housings can easily be us...

Страница 11: ... 20 Transformer Wired for 24 Volt Camera 5 6 6 LTC 9384 50 Housings These housings require connection to 230VAC and are designed for use where the site power is 230 volts The LTC 9384 50 Housings can easily be used with either 230 volt or 24 volt cameras The internal transformer provides 24VAC for both the heater and 24 volt camera power Do not remove the transformer insulator No user serviceable ...

Страница 12: ...id tight seal Failure to do so could allow water to enter the housing and damage the camera and lens 5 8 Lens Wiring WARNING Use only the cables specified under INSTALLATION Cable Requirements for video coax wiring connection 1 If installing a zoom lens insert the lens control cable with the installed seal cap in through the right fitting at the rear of the cradle Attach the lens wiring to the len...

Страница 13: ...radle assembly by applying pressure onto the rear cap until the end of the cradle is approximately flush with the back of the housing see FIGURE 16 FIGURE 16 Inserting the Cradle Assembly CAUTION If a pull seal is installed in the breather hole be careful not to pinch the head of the pull seal Damage to the pull seal may allow water to enter the housing causing damage to the camera and lens 2 Tigh...

Страница 14: ...red Transformer Kit 315 3805 001 3 315 3809 001 1 24VAC Prewired Transformer 15 2 Rivet 5 16in 6 1 Transformer Insulator 230 VAC Prewired Transformer Kit 315 3806 001 3 315 3810 001 1 230VAC Prewired Transformer 15 2 Rivet 5 16in 6 1 Transformer Insulator Housing Kit 315 3807 001 11 1 Housing 1 2 Silicone O ring HARDWARE KIT Hardware Kit 315 1514 005 Quantity Part Description 3 Cable Tie 2 BHCS 1 ...

Страница 15: ...LTC 9384 Series Instruction Manual EN 15 Bosch Security Systems September 1 2004 ...

Страница 16: ...ty Systems Inc 850 Greenfield Road Lancaster PA 17601 USA Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Republic of Singapore Tel 65 6 319 3486 ...