background image

EN

| 14

Bosch Security Systems | January 19, 2006

LTC 8561 | 

Instruction Manual

Installation

1. Prepare the ends of cables by stripping about

1⁄4-inch of insulation from the ends.

2. Connect the pan-right wire to conductor 1 on

terminal strip, J406.

3. Connect the pan-left wire to conductor 2 on

terminal strip, J406.

4. Connect the tilt-up wire to conductor 3 on

terminal strip, J406.

5. Connect the tilt-down wire to conductor 4 on

terminal strip, J406.

6. Note that not all pan/tilt heads have an auto-

pan feature or separate auto-pan wires. Refer to
your pan/tilt manual and if no auto-pan wire is
provided, omit the next step.

7. Connect the auto-pan wire to conductor 5 on

terminal strip, J406.

4.24 Auxiliary Circuits Pin Assignment

NOTE: For the LTC 8566/60 and 8566/50, the
maximum total current output, including Pan/Tilt
Output, Auxiliary 1 Output, and Auxiliary Supply
Output, is 2 A.

All receiver/driver versions have three relay
auxiliaries, each with a set of normally open and
normally closed contacts. These contacts permit the
use of line voltages or signals to be switched on and
off. An auxiliary supply output is provided to allow
operation of appliances at the pan/tilt output voltage
level. This auxiliary supply output is fused through the
pan/tilt/auxiliary supply fuse.

These circuits are controlled by executing commands
for auxiliary 2, 3, and 4. In actuality, Auxiliary 1 is
used as the auto-pan hardwire control. If software auto-
pan is in use, the installation may make use of
Auxiliary 6 to activate the auxiliary output located in
the pan/tilt connector.

Auxiliary #3 has a special mode of operation when
DIP switch S103, #2 is in the ON position. In this
mode, the auxiliary activates and latches automatically
when the IRIS control is used on the system keyboard.
This function is used to control the special ground
connection of a zoom lens which provides a manual-
iris override feature. More information is provided in
the S103, #2, Setting Option Switches section of this
manual.

Refer to the two following sections for connection
details.

4.25 Auxiliary Supply Output

NOTE: For the LTC 8566/60 and LTC 8566/50, the
maximum total current output, including Pan/Tilt
Output, Auxiliary 1 Output, and Auxiliary Supply
Output, is 2 A.

When it is desired to operate an appliance at the
pan/tilt output voltage level, the auxiliary supply
output may be used to supply power to the appliance.
Use the following steps to make use of the auxiliary
supply output. Locate terminal strip J402 AUX
SUPPLY, J405 AUX 2, J407 AUX 3, and J408 AUX 4.
Choose one of the three auxiliary terminal strips: J405,
J407, or J408.

1. Connect a jumper wire from pin 1 of J402 to

pin 2 of the selected strip.

2. Connect the appliance load to pin 1 (normally

open contact) or pin 3 (normally closed contact)
depending upon your requirements.

3. Connect the appliance return to pin 2 of J402.

4.26 Contact Auxiliary

To use an auxiliary as a circuit switch, follow these
steps:

Locate terminal strip J405 AUX 2, J407 AUX 3, and
J408 AUX 4. Choose one of the three auxiliary
terminal strips: J405, J407, or J408.

1. Use the contact as a series switch and connect

the circuit to pins 1 and 2 for a normally open
switch, or to pins 2 and 3 for a normally closed
switch.

2. If Auxiliary #3 is being used to activate the

manual-iris override mode of a zoom lens
equipped with this feature, use the normally
open contact connections. One side of the
contact should be connected to the zoom lens
special ground wire, and the other contact
should be jumpered to the lens motor common
terminal on J105.

Содержание LTC 8561 Series

Страница 1: ...Instruction Manual EN Single Channel On site Receiver Drivers LTC 8561 8564 20 8566 Series ...

Страница 2: ...hock or other hazards 9 Safety Check Upon completion of servicing or repairs to the unit ask the service technician to perform safety checks to ensure proper operating condition 10 Power Sources Operate the unit only from the type of power source indicated on the label If unsure of the type of power supply to use contact your dealer or local power company For units intended to operate from battery...

Страница 3: ...not exceed its maximum operating temperature requirements 2 Mechanical Loading Mounting of the equipment in a rack shall be such that a hazardous condition is not achieved due to uneven mechanical loading Safety Precautions Attention Installation should be performed by qualified service personnel only in accordance with the National Electrical Code or applicable local codes Power Disconnect Units ...

Страница 4: ...iempre que el cable de alimentación esté conectado a la fuente de alimentación Sin embargo la unidad sólo funciona cuando el interruptor está en la posición de encendido El cable de alimentación es la principal fuente de desconexión de todas las unidades PRECAUCIÓN PARA DISMINUIR EL RIESGO DE DESCARGA ELÉCTRICA NO RETIRE LA CUBIERTA NI LA PARTE POSTERIOR NO EXISTEN PIEZAS DE RECAMBIO EN EL INTERIO...

Страница 5: ... prodotto Ciò comporta un potenziale rischio di scosse elettriche Si consiglia di consultare le istruzioni operative e di manutenzione interventi tecnici contenute nella documentazione fornita con il dispositivo Medidas de Segurança Atenção a instalação deve ser executada apenas por técnicos qualificados da assistência de acordo com o código eléctrico nacional ou os códigos locais aplicáveis Corte...

Страница 6: ... S104 2 3 10 4 14 Lens Voltage S104 4 10 4 15 Site Address 10 4 16 Field Setup 11 4 17 Connecting Line Power 11 4 18 LTC 8564 20 AC Supply Wiring Guide 11 4 19 Connecting Biphase Signal Cable 12 4 20 Connecting the RS 232 Signal Cable 12 4 21 Connecting Lens Motor 13 4 22 Connecting Pre position 13 4 23 Connecting Pan Tilt 13 4 24 Auxiliary Circuits Pin Assignment 14 4 25 Auxiliary Supply Output 1...

Страница 7: ...l BoschCCTVparts ca slr com Canada Phone 514 738 2434 Europe Middle East Asia Pacific Region Phone 32 1 440 0711 For additional information see www boschsecuritysystems com 3 DESCRIPTION The LTC 8561 Series LTC 8564 20 and LTC 8566 Series On site Receiver Drivers are control data decoder units and motor drivers for pan tilt units and lenses These receiver drivers are used in conjunction with the A...

Страница 8: ... easy by removing the metal frame that all components are attached to 1 On a flat surface open the box containing the receiver driver unit 2 Carefully remove the unit from the box 3 Place the base part of the receiver driver on the bench face up with the circuit board showing Use a Phillips screwdriver to remove the four corner screws 4 Using the thumb and forefinger of both hands reach down on th...

Страница 9: ...printed circuit board 2 Each switch is numbered 1 to 4 and corresponds to the auxiliaries 1 to 4 3 To make an auxiliary momentary push the switch of the desired auxiliary to the OFF direction 4 To make an auxiliary latching push the switch of the desired auxiliary to the ON direction These switches may be easily changed at any time or may be set prior to installation 4 6 Lens Polarity S102 2 To ac...

Страница 10: ...e a Manual iris Override feature this switch should be placed in the OFF position In the manual iris override mode Auxiliary 3 operates as a circuit switch between the special ground wire of the zoom lens and the lens motor common terminal see lens data sheet for pinout connection information When the switch is ON Auxiliary 3 is automatically activated and latched when the IRIS control on the syst...

Страница 11: ...0 AC Supply Wiring Guide Use all proper precautions when installing the line voltage cable to the device Refer to the following procedure for line power installation CAUTION Before proceeding be sure to disconnect the live power from the cable to be installed into the receiver driver Be sure that the receiver driver is of the proper line voltage type for line power being used 1 Prepare the line an...

Страница 12: ...last on site receiver and a signal cable is hooked up as follows between the devices 1 Connect one wire of the approved type signal cable to terminal 4 of the signal in terminal block Note that this color wire is the SIGNAL for the next device 2 Connect the other wire to terminal 5 of the signal in terminal block Note that this color wire is the SIGNAL for the next device 3 Connect the shields of ...

Страница 13: ...ng steps 1 Prepare the ends of cables by stripping about 1 4 inch of insulation from the ends 2 Connect the pan tilt sensor ground cable to conductor 5 on terminal strip J111 3 Connect the first pan position cable to conductor 2 on terminal strip J111 4 Connect the second pan position cable to conductor 3 on terminal strip J111 This step is required only on pan motors with a continuous 360 degrees...

Страница 14: ... auxiliary activates and latches automatically when the IRIS control is used on the system keyboard This function is used to control the special ground connection of a zoom lens which provides a manual iris override feature More information is provided in the S103 2 Setting Option Switches section of this manual Refer to the two following sections for connection details 4 25 Auxiliary Supply Outpu...

Страница 15: ...own so it can be reentered when finished with the local test procedure 2 From the table below enter the desired number of the function you wish to test using the digital thumbwheel switches 3 Push the local test push button to activate test as selected 4 Release push button and repeat steps 2 and 3 if additional tests are desired 5 Be sure to set the thumbwheel switches back to their original addr...

Страница 16: ...TC 0600 or the LTC 0500 Series cameras need to be addressed to 1 minus the address of the receiver driver then physically wired from the RS 232 port of the camera to the RS 232 TX port of the receiver driver For example if the receiver driver is set to address 02 the camera needs to be addressed as 01 This camera secondary addressing is accomplished via PC software LTC 0650 7 SUMMARY OF PIN ASSIGN...

Страница 17: ...ing turn on 1 A drive capability Six conductor terminal block J406 and two conductor terminal block J401 are found near the left hand side of the lower printed circuit board Pin one is to the left side of connector 7 5 1 J406 P T Output Pin No Signal Name Remarks 1 RIGHT Connect to pan right control wire 2 LEFT Connect to pan left control wire 3 UP Connect to tilt up control wire 4 DOWN Connect to...

Страница 18: ...7 AUX 1 MOMENTARY NORMAL AUX 1 AUX 7 SOFTWARE CONTROL HARDWARE CONTROL 1 2 3 4 FUNCTION ON OFF DIP SWITCH SETTINGS CAUTION PAN TILT MOVEMENT OCCURS UPON INITIAL POWER UP OF RECEIVER DRIVER MOMENTARY MOMENTARY MOMENTARY 0023 AUX 7 ON 0024 AUX 7 OFF SHOT PP1 PP99 SET PP1 PP99 0000 CALIBRATION P T POSITION SENSE PAN2 PAN1 TILT AUX 2 NO NC FUSE AUX 3 NO NC AUX 4 NO NC LENS POSITION SENSE FOCUS ZOOM LE...

Страница 19: ...Bosch Security Systems January 19 2006 LTC 8561 Instruction Manual Illustrations EN 19 ...

Страница 20: ...96 security sales us bosch com http www boschsecurity us Europe Middle East Africa Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Phone 31 0 40 27 83955 Fax 31 0 40 27 86668 emea securitysystems bosch com http www boschsecurity com Asia Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3450 Fax 65 6319 3499 apr securitysystems bosc...

Отзывы: