background image

LTC 5136 Series | 

Instruction Manual

Controller Operation

Bosch Security Systems | 04 September 2003

EN

| 14

5. Press 

ON-1-ENTER

and the address is set.

Once the 

Fast Address

is set, the switch address

(thumbwheel) is ignored. The 

Fast Address

is

stored to non-volatile memory, and will not
change if power is removed or factory defaults
are restored (

SET-899-ENTER

).

To reset the dome’s address to the switch
address (thumbwheel), repeat the above
steps and end by pressing 

OFF-1-ENTER

.

To check/confirm the address, call up the
camera and press 

ON-997-ENTER

. This

command causes all cameras to briefly
display their addresses.

6

CONTROLLER OPERATION

Operation is quite simple. If the camera number to be
controlled is not visible in the LED displays, use the
numeric keypad to select the desired camera, then
press 

ENTER

. The camera can now be operated using

the appropriate joystick and/or lens controls. If
appropriate, pre-position scenes and auxiliary functions
can also be entered.

Note that a delay of more than 3-4 seconds while
entering a selection results in the Controller returning
to the default camera entry mode. If this condition
occurs, start the selection again, from the beginning.

A complete description of the controls and indicators is
provided in the next section.

6.1

Controls/Indicators

LED Indicators: The four digit, 7-segment LED display
is used to display data entry and the selected camera
number.

SET 

key

:

This key is used to set pre-position scenes of

all AutoDome cameras and Allegiant Series Receiver/
Drivers which are equipped with this option. Operate
the joystick and lens controls to position the camera to
the desired scene to be programmed. Press 

SET

, then

enter the desired pre-position number on the numeric
keypad (1 to 99). Press 

ENTER

to store the position.

Certain pre-position numbers are also used to program
certain AutoDome features. Refer to the AutoDome
operation manual for a complete listing of the available
features.

USER 

key

:

Press 

USER-1-ENTER

to enter the

Controller diagnostic mode. This function can be used

to ensure that all Controller LEDs and buttons are in
working order. It also automatically calibrates the
center position of the analog joystick. Upon entering
this mode, the Controller sounds a short beep. The
display readouts and LEDs behind the first two rows of
buttons also illuminate for about two seconds. During
this time, the joystick undergoes calibration, so be
careful not to move it until the LED displays have
gone dark. The operator should note any LED display
failures during the time they are illuminated.

Each key may now be pressed to display a unique
code number associated with that key. Use the table
below to ensure that all keys are operating properly.
Push the 

USER

key last, as this will cause the

Controller to exit the test mode.

NOTE: The 

x

digit shown in the number column, for

up, down, left, right, and zoom values, indicates a s

peed

value, and will change based on how far the control is
activated.

Key

Number

Key

Number

Set

0009

9

0029

Camera

0025

0

0014

Shot

0010

Enter

0030

On

0018

Clear

0038

Off

0026

Focus (up)

0043

1

0011

Focus (down)

0044

2

0019

Iris (up)

0045

3

0027

Iris (down)

0046

4

0012

Up

1x53

5

0020

Down

0x51

6

0028

Left

1x52

7

0013

Right

0x54

8

0021

Zoom (CW)

1x41

Zoom (CCW)

0x42

Содержание LTC 5136/51

Страница 1: ...LTC 5136 Series Instruction Manual EN AutoDome Controller ...

Страница 2: ... intended to operate from battery power or other sources refer to the operating instructions 11 Grounding or Polarization This unit may be equipped with a polarized alternating current line plug a plug having one blade wider than the other This plug will fit into the power outlet only one way This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the plug...

Страница 3: ...ning For added protection of this unit during a lightning storm or when it is left unattended and unused for long periods of time unplug it from the wall outlet and disconnect the cable system This will prevent damage to the unit due to lightning and power line surges FCC ICES Information U S A and Canadian Models Only This device complies with part 15 of the FCC Rules Operation is subject to the ...

Страница 4: ...enance servicing instructions in the literature accompanying the appliance Sécurité Attention L installation doit être exclusivement effectuée par un technicien spécialisé conformément à la réglementation du code national de l électricité des États Unis NEC ou à la réglementation locale Coupure de l alimentation Les appareils avec ou sans commutateur ON OFF marche arrêt sont alimentés dès que le c...

Страница 5: ...Dokumentation hinweisen die dem Gerät beiliegt Precauciones de Seguridad Atención La instalación debe realizarla personal cualificado en cumplimiento estricto del código eléctrico nacional en el caso de los EE UU o de los códigos locales aplicables Para Desconectar la Alimentación Unidades no equipadas con interruptores ON OFF son alimentadas cuando el cable de alimentación es conectado a la corri...

Страница 6: ...eld om de gebruiker te waarschuwen voor de aanwezigheid van belangrijke bedienings en onderhouds service instructies in de documentatie die met het product zijn meegeleverd Sicurezza Precauzione affidare l installazione al solo personale qualificato e nel rispetto del Codice elettrico nazionale USA o dei codici locali pertinenti Scollegamento dell alimentazione Gli apparecchi con o senza commutato...

Страница 7: ...amação dentro de um triângulo equilátero serve para alertar o utilizador para a presença de instruções de funcionamento e manutenção importantes na documentação fornecida com o aparelho Zasady Bezpieczeństwa Uwaga Instalację urządzenia powinien wykonać tylko wykwalifikowany personel zgodnie z przepisami NEC lub odpowiednimi przepisami miejscowymi Odłączanie zasilania Urządzenia zarówno nie posiada...

Страница 8: ...ALLATION 10 4 1 General 10 4 2 Installation using Biphase Code 10 4 3 Installation using RS 232 Data Direct to Camera Site 11 4 4 Installation using an RS 232 Data Transmission Link to a Biphase Camera Site 12 4 5 AutoDome Camera or Receiver Driver Site Configuration 13 5 SETTING FAST ADDRESS FEATURE 13 6 CONTROLLER OPERATION 14 6 1 Controls Indicators 14 7 TECHNICAL REFERENCE 16 8 DATA CONVERTER ...

Страница 9: ... 32 1 440 0711 For additional information see www boschsecuritysystems com NOTE Grounded wrist straps must be worn and proper ESD safety precautions observed when handling the electrostatic sensitive printed circuit boards 3 DESCRIPTION The LTC 5136 Series Controllers are designed for use with the Bosch AutoDome Series cameras They can also be used to operate any of the conventional Allegiant Seri...

Страница 10: ...sing This document also includes various diagrams of typical applications that will be helpful to refer to during installation 4 2 Installation Using Biphase Code See Figures 3 and 4 Install the supplied interface unit in a location close enough to the Controller unit so the that supplied 3 m 10 ft data cable can be used Note that the interface unit is rated for indoor use only If desired four hol...

Страница 11: ...e side of the junction box If the power supply cable must be attached to the power supply the polarity is not important the Interface Unit is not polarity sensitive Plug the power supply into a suitable AC power source Connect the supplied 3 m 10 ft data cable with two RJ 11 connectors between the Controller unit and the junction box The orientation is not important either end may be connected to ...

Страница 12: ...2 Junction Box Supplied with LTC 8557 Series Kit Pins 1 and 2 are not used Pin 3 is the Controller s RS 232 TX output and Pin 4 is the Signal Ground connection Be sure to use cable suitable for RS 232 signals Connect the wire from terminal 3 to the RX connection of the RS 232 transmission device Respectively connect the wire from terminal 4 to the data ground connection At the camera side of the R...

Страница 13: ...itch address thumbwheel Fast Address can also be used to change addresses even if the thumbwheel switch is set The following is an example of how to Fast Address an AutoDome ID number 26636 logical camera 3 The AutoDome being Fast Addressed has the switch address thumbwheel set to 0 1 Call up the camera to the screen you are viewing i e CAMERA 3 ENTER 2 Press ON 999 ENTER The screen shown in FIGUR...

Страница 14: ...ich are equipped with this option Operate the joystick and lens controls to position the camera to the desired scene to be programmed Press SET then enter the desired pre position number on the numeric keypad 1 to 99 Press ENTER to store the position Certain pre position numbers are also used to program certain AutoDome features Refer to the AutoDome operation manual for a complete listing of the ...

Страница 15: ...legiant Series Receiver Drivers Press OFF then enter the desired auxiliary number on the numeric keypad and press ENTER to complete the action Certain auxiliary numbers are also used to program certain AutoDome features Refer to the AutoDome operation manual for a complete listing of the available features NUMERIC keypad These keys are used to enter numeric data When the first numeric key is press...

Страница 16: ...Power Supply Adapter Typical AutoDome Cameras or Allegiant Receiver Driver units RS 232 Data Power Up to 16 biphase control code outputs Video Signal Controller Video Signal DVR or Video Switcher Video Monitor Data Converter Unit Power Supply Adapter Typical AutoDome Cameras or Allegiant Receiver Driver units RS 232 Data Power Typical biphase control code output Video Signal Controller Daisy Chain...

Страница 17: ...ical AutoDome Camera or Allegiant Receiver Driver unit RS 232 Data Power Video Signal Controller Video Monitor Power Supply Adapter RS 232 Cable or Communication Link Typical AutoDome Cameras or Allegiant Receiver Driver units Video Signal Controller Biphase Data DVR or Video Switcher Video Monitor Video Signal LTC 8557 Junction Box RS 232 Data Power Power Supply Adapter RS 232 Cable or Communicat...

Страница 18: ... Conductor 3 m 10 ft Data Cable Detail Figure 8 Rear Panel Controller Connector Detail Figure 9 Mounting Dimensions of Supplied Interface Box Pin 6 Pin 1 Pin 1 Pin 6 Pin 6 Pin 1 Connector Pinouts 1 12V 2 Not used 3 Rx Not used 4 Tx 5 Signal Ground 6 12V 122 4 80 70 2 75 154 6 08 108 4 26 mm in 127 5 0 38 1 5 132 5 2 mm in ...

Страница 19: ...CONVERTER PINOUTS Data In 9 Pin Connector Male Pin Connection 1 No Connection 2 Rx 3 No Connection 4 No Connection 5 Ground 6 No Connection 7 No Connection 8 No Connection 9 No Connection KBD RJ 11 Designations If Used Pin Connection 1 Output Voltage 2 Signal Ground 3 Rx 4 Ground 5 No Connection 6 Output Voltage ...

Страница 20: ... Security Systems Inc 850 Greenfield Road Lancaster PA 17601 EE UU Tel 800 326 3270 Fax 1 717 735 6560 www boschsecuritysystems com Robert Bosch GmbH Geschäftsbereich Postfach 10 60 50 70049 Stuttgart Telefax 0711 811 12 34 Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands Tele 31 40 27 80000 ...

Отзывы: