Operation

Initial Operation

Protect the measuring tool against moisture and direct sun light.

Do not subject the measuring tool to extreme temperatures or variations in 
temperature. 

As an example, do not leave it in vehicles for a long time. In case of 

large variations in temperature, allow the measuring tool to adjust to the ambient 
temperature before putting it into operation. In case of extreme temperatures or 
variations in temperature, the accuracy of the measuring tool can be impaired.

Setting Up the Measuring Tool (see figure A)

Set up the measuring tool at least 5 m away from the line laser. Switch on the pulse 
function of the line laser. Select an operating mode on the line laser where either only 
one horizontal or vertical laser plane is generated.

Note: 

Do not select an operating mode with both horizontal and vertical laser plane 

(cross-line operation), as otherwise faulty height indications of the laser beam may 
occur.
Position the measuring tool in such a manner that the laser beam can reach the recep-
tion area 

10

. Align the measuring tool in such a manner that the laser beam runs lat-

erally through the reception area (as shown in the figure). 

Switching On and Off

A loud audio signal sounds when switching on the measuring tool. Therefore, 
keep the measuring tool away from your ear or other persons when switching 
on. 

The loud audio signal can cause hearing defects.

To 

switch on

 the measuring tool, press the On/Off button 

2

. All display indicators as 

well as all LEDs light up briefly and an audio signal sounds.
To 

switch off

 the measuring tool, press the On/Off button 

2

 again. Before switching 

off, all LEDs briefly light up.
When no button is pressed on the measuring tool for approx. 20 minutes and when no 
laser beam reaches the reception area 

10

 for 20 minutes, the measuring tool auto-

matically switches off in order to save the battery. The switching off is indicated by 
brief lighting up of all LEDs.

Selecting the Setting of the Centre Indicator

You can use button 

1

 to specify the accuracy with which the position of the laser beam 

is indicated as “centred” on the reception area:
– Measuring accuracy “Fine” (indication 

g

 on the display),

– Measuring accuracy “Coarse” (indication 

f

 on the display).

Whenever switching on the measuring tool, the accuracy level “coarse” is set.

OBJ_BUCH-821-004.book  Page 16  Wednesday, February 10, 2016  8:48 AM

Содержание LR 2

Страница 1: ... This ensures that the safety of the measuring tool is main tained Do not operate the measuring tool in explosive environments such as in the presence of flammable liquids gases or dusts Sparks can be created in the measuring tool which may ignite the dust or fumes Keep the measuring tool away from cardiac pacemakers The mag net plate 5 generates a field that can impair the function of cardiac pac...

Страница 2: ...601 K69 100 Working range1 5 50 m Receiving angle 90 Measuring accuracy2 Fine Coarse 1 mm 3 mm Operating temperature 10 C 50 C Storage temperature 20 C 70 C Battery 1 x 9 V 6LR61 Operating time approx 30 h Weight according to EPTA Procedure 01 2014 0 27 kg Degree of protection IP 54 dust and splash water protected Dimensions length x width x height 74 x 41 x 150 mm 1 The working range can be decre...

Страница 3: ...pressureleveloftheaudiosignalatonemeterdistance is 80 dB A Do not hold the measuring tool close to your ear Assembly Inserting Replacing the Battery Alkali manganese batteries are recommended for the measuring tool Pull the latch 11 of battery lid outward and open the battery lid 13 When inserting the battery pay attention to the correct polarity according to the rep resentation on the inside of t...

Страница 4: ...a 10 Align the measuring tool in such a manner that the laser beam runs lat erally through the reception area as shown in the figure Switching On and Off A loud audio signal sounds when switching on the measuring tool Therefore keepthemeasuringtoolawayfromyourearorotherpersonswhenswitching on The loud audio signal can cause hearing defects To switch on the measuring tool press the On Off button 2 ...

Страница 5: ...n the audio signal is switched on a fast beat signal sounds Move the measuring tool downward in the direction of the arrow Measuringtoolincentreposition Whenthelaserbeamrunsthroughthereception area 10 at the centre mark 8 the centre indicator c on the display and the corre sponding centre indication LED 7 light up When the audio signal is switched on a continuous signal sounds Audio Signal for Ind...

Страница 6: ...te 5 Maintenance and Service Maintenance and Cleaning Keep the measuring tool clean at all times Do not immerse the measuring tool in water or other fluids Wipe off debris using a moist and soft cloth Donotuseanycleaning agents or solvents After sales Service and Application Service Our after sales service responds to your questions concerning maintenance and repair of your product as well as spar...

Страница 7: ...chservicecentre bosch com Ireland Origo Ltd Unit 23 Magna Drive Magna Business Park City West Dublin 24 Tel Service 01 4666700 Fax 01 4666888 Australia New Zealand and Pacific Islands Robert Bosch Australia Pty Ltd Power Tools Locked Bag 66 Clayton South VIC 3169 Customer Contact Center Inside Australia Phone 01300 307044 Fax 01300 307045 Inside New Zealand Phone 0800 543353 Fax 0800 428570 Outsid...

Страница 8: ...223 E Mail bsc zsd co za Bosch Headquarters Midrand Gauteng Tel 011 6519600 Fax 011 6519880 E Mail rbsa hq pts za bosch com Disposal Measuring tools accessories and packaging should be sorted for environmental friendly recycling Do not dispose of measuring tools and batteries rechargeable batteries into house hold waste Only for EC countries According to the European Guideline 2012 19 EU measuring...

Страница 9: ...nstructions les dispositifs de protection intégrés risquent de ne pas fonctionner correctement BIEN CONSERVER LES PRÉSENTES INS TRUCTIONS Ne faire réparer l appareil de mesure que par une personne qualifiée et seule ment avec des pièces de rechange d origine Ceci permet d assurer la sécurité de l appareil de mesure Ne pas faire fonctionner les appareils de mesure en atmosphère explosive par exempl...

Отзывы: