Bosch Security Systems | 2006-11 | 9922 141 50751en
Plena Power Amplifier
| Installation and User Instructions | Amplifiers
en
| 11
3.3 Internal
setting
The output voltage of the priority controlled
loudspeaker outputs can be set to 70 V or 100 V. A high
power fuse inside the unit is used as a voltage selector.
Insert the high power fuse into fuse holder F701 for
100 V selection (default setting), or into fuse holder
F702 for 70 V selection. This selection does not affect
the output voltage of the loudspeaker direct outputs.
Refer to figure 3.3.
figure 3.3: Internal fuse setting LBB1930/20, LBB1935/20, LBB1938/20
F701
100V
70V
F702
figure 3.4: Internal fuse setting 1P1000
F701
100V
70V
F702