Confidential
| CM/PJ-IVS | 2020-06-05
© 2020 Robert Bosch LLC and affiliates. All rights reserved.
Device Specification
4
Set up of Hardware
Cellular bands
•
Device will be glued onto the windshield
via glue pad
•
Device will be connected to vehicle power
and ground
•
The average power consumption of the
device is:
•
Active mode: ca. 200 mA
•
Low-power mode: ca. 15 mA
•
Ultra-low power mode: ca. 150 µA
•
The network provider is Vodafone
•
The data from the device is sent to the
Amazon cloud EU-server
•
No ASIL required as no direct interface
with vehicle
Description
Operating temperature
-25
°
C to +60
°
C (-13
°
F to 140
°
F)
Storage temperature
-25
°
C to +70
°
C (-13
°
F to 158
°
F)
Relative operating humidity
20% to 80%, noncondensing
Input voltage
+8V to +16V DC
Power consumption
500mA @ 12V
Dimensions (W x L x H)
80mm x 80mm x 27mm
Weight
90g
Outside the operating temperature, the correct function of IVS-
Slim is not guaranteed.
Cross-Domain Computing Solutions I 2021-05-18
© Robert Bosch GmbH 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.