Safety
English 2
It is the responsibility of the owner and the installer to determine if additional
requirements and/or standards apply to specific installations.
•
Installation must conform with local codes or, in the absence of local codes,
with the National Fuel Gas Code, ANSI Z223.1/NFPA 54.
•
The appliance must be electrically grounded in accordance with local codes
or, in the absence of local codes, with the National Electrical Code ANSI/
NFPA 70, latest edition. (In Canada, installation must be in accordance with
the CAN 1-B149.1 and .2 Installation Codes for Gas Burning Appliances and/
or local codes).
Electric Safety
•
Before you plug in an electrical cord, be sure all controls are in the OFF posi-
tion.
•
For appliances equipped with a cord and plug, do not cut or remove the
ground prong. It must be plugged into a matching grounding type receptacle
to avoid electrical shock. If there is any doubt as to whether the wall recepta-
cle is properly grounded, the customer should have it checked by a qualified
electrician.
•
If required by the National Electrical Code (or Canadian Electrical Code), this
appliance must be installed on a separate branch circuit.
•
Only a power-supply cord kit rated for this appliance and marked "for use with
ranges" shall be used.
•
Installer - show the owner the location of the circuit breaker or fuse. Mark it for
easy reference.
•
Important - Save these instructions for the local electrical inspector's use.
•
Before installing, turn power OFF at the service panel. Lock service panel to
prevent power from being turned ON accidentally.
•
Be sure your appliance is properly installed and grounded by a qualified tech-
nician. Installation, electrical connections and grounding must comply with all
applicable codes.
Gas Safety
•
Install a gas shutoff valve near the appliance. It must be easily accessible in
an emergency.
•
Leak testing must be conducted by the installer according to the instructions
in this manual.
•
The appliance and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing at pressures in excess
of ½ psi (3.5 kPa).
•
The appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas sup-
ply piping system at test pressures equal to or less than ½ psi (3.5 kPa)
•
The minimum supply pressure must be 1" water column above the manifold
pressure printed on the data plate.
Содержание Integra HDI7052U
Страница 3: ......