EN
| 9
Bosch Security Systems | 26 March 2004
HSG9483 Series
|
Instruction Manual
|
Installation
4.5
Camera/Lens Installation
1.
Remove the two screws holding the camera
tray to the housing. Remove tray from the
housing.
2.
If using the feed-through feature, refer to
SECTION 4.6.3.
3.
Mounting fixed lens cameras in all housings:
a.
Attach the lens to the camera.
b.
Combine the 4mm and the 9mm
Spacers provided to mount Dinion
TM
Series cameras to the camera tray (see
FIGURE 2). For other cameras, use
different combinations of the spacers.
Figure 2: Spacers
Figure 3: Spacers with Fixed Lens Camera
c.
Use the 1/4-20 x 5/8in. screw to secure
the camera and spacer to the camera
tray. Slide the camera/lens tray into the
slot near the clasp side of the housing.
Slide the entire assembly forward
approximately 5mm (0.2in) from the
front of the window. Install screws into
the appropriate holes (see FIGURE 4).
Figure 4: Sliding Camera/Lens Tray Assembly into Slot
4.
For installations of zoom lens cameras:
a.
Attach the lens to the camera.
b.
Use the various 1/4-20 screws and
appropriate 4mm and/or 9mm
spacers provided to mount the
camera and the lens to the camera
tray (see FIGURE 5).
Figure 5: Attaching Camera with Zoom Lens
4.6
Camera/Lens Wiring
See SECTION 5 for HSG9483/22, /52, /53 Models.
WARNING: To wire cameras and lenses,
use only the cables specified under
INSTALLATION, Cable Requirements.
1.
Fittings
a.
The two 3/8in. NPT fittings accept a
round cable with diameter from 4.0mm
(0.16in) to 7.0mm (0.28in). The larger
1/2in. NPT fitting will accept cables with
diameters from 6.5mm (0.26in) to
10.5mm (0.42in).
Be sure to securely tighten all fittings to
ensure a liquid-tight seal. Failure to do so
could allow water to enter the housing and
damage the camera and lens.
If a sealant is used, be sure it is a neutral cure
type. Sealants that release acetic acid may
harm camera electronics.
Use of
drip loops
is recommended on the
wiring outside of the rear end cap.
2.
Conduit
These housings are designed to allow direct
connection of conduit.
a.
Remove the rear hole plugs and attach
the conduit and conduit fittings directly
to the housing rear cap. The holes
accept either 3/8in. NPT or 1/2in. NPT
conduit fittings. Any unused holes must
be covered using the plugs provided
with the housing.
T
ray
Correctly
Installed
in Slot
Tray
Incorrectly
Installed on
Top of Slot
9mm Spacer
4mm Spacer
Spacers Combined for 13mm
5/8in Screw & Flat Washer
Screws & Flat Washers
1/4in
5/8in