5
Connection in accordance with EN 10226 R
^
(TS 61-210 EN
10226 R
^
)
1.
Place the new seal in the connection piece. Make sure the
seal is seated correctly.
2.
Secure the gas connection piece to the appliance
using a 22
mm spanner
and place the connection piece into the
connection piece using a 24 mm spanner.
3.
Secure the connection piece using a
24 mm spanner
. Use a
24 mm spanner to place the threaded fitting of the gas pipe
or safety gas hose on the connection piece and tighten it
firmly.
4.
For information on how to carry out leak testing, see the
section entitled
"Leak testing"
. Open the gas connection shut-
off.
:
Risk of gas leak!
When connecting the gas pipe or safety gas hose, do not
tighten the gas connection piece on the appliance using a 22
m spanner. This may damage the connection piece.
Notes
■
*R
^
: EN 10226 R
^
(TS 61-210 EN 10226 R
^
)
■
Use a torque wrench to connect the appliance.
Electrical connection
Only licensed specialists may connect the appliance.It is
important that you comply with the requirements of your
electricity supplier.
The appliance is designed to operate at 220-240 V. A 16 A
fuse is required for connection.
Any damage arising from the appliance being connected
incorrectly will invalidate the warranty.
Caution!
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
■
The appliance must be disconnected from the power supply
whenever installation work is being carried out.
■
The appliance fulfils the requirements of protection class I
and may only be connected to an earthed socket.