8
Caution!
If the pressure of your local gas supply is higher than:
natural gas (G20) 2,5 kPa;
LPG (G30) 3,6 kPa;
or LPG (G31) 4,5 kPa; for safety reasons, the appliance must
be equipped with a suitable pressure regulator. The connection,
maintenance and setting of the pressure regulator must be
carried out by an approved gas fitter.
If you do not know the pressure of your local gas supply, ask
your gas supplier.
For your safety
This appliance is adjusted to operate on LPG only.
Faults in the gas installation/smell of gas
If you notice a smell of gas or faults in the gas installation, you
must
■
immediately shut off the gas supply and/or close the gas
cylinder valve
■
immediately extinguish all naked flames and cigarettes
■
switch off electrical appliances and lights
■
open windows and ventilate the room
■
call the after
sales service or the gas supplier
Burn back
Fire in burner tube or chamber
In the event of a burn-back, where the flame burns back to the
jet, immediately turn off the gas supply at the control valve on
the panel.
After ensuring the flame is extinguished, re-light the appliance
in the normal manner.
Should the appliance again burn back, close the control valve
and call a service technician. Do not use the appliance again
until the service technician has declared that it is safe to do so.
Gas-pressure regulator
This appliance requires an operating pressure of 2,8 kPa at the
appliance. A suitable LPG regulator that coplies with the
requirements of SANS 1237 must be installed.
Important information for the user
This appliance may only be installed by a registeres LP Gas
installer.
All registered installers are issued with a card carrying their
registration number. Ask to be shown the card before allowing
the installation work to be shown the card before allowing the
installation work to commence and make a note of the installer
QCC number.
Upon completion of the installation, the installer is required to
explain the operational details of the appliance together with
the safety instructions.
You should only sign for acceptance of the installation and be
provided with a copletion certificate. You should only sign for
acceptance of the installation when the installation is completed
to your satisfaction.
Note that your invoice is required in the event that you wish
make a quarantee claim.
Important information for the installer
This appliance may only be installed by a registered LP Gas
installer registered with the Liquefied Petroleum Gas
Association of Southern Africa.
The appliance must be installed in accordance with the
requirements of SANS 10087-1 and any fire department
regulations and/or local bylaws applicable to the area. If in
doubt check with the relevant authority before undertaking the
installation.
Upon completion of the installation you are required to fully
explain and demonstrate to the user the operational details and
safety practices applicable to the appliance and the installation.
Moving the appliance by the gas line or door handle
Do not move the appliance while holding the gas line; the gas
pipe could be damaged. There is a risk of a gas leak! Do not
move the appliance while holding it by the door handle. The
door hinges and door handle could be damaged.
Electrical connection
Caution!
■
Have the appliance set up by your after-sales service. A 16 A
fuse is required for connection. The appliance is designed for
operation at 220-240 V.
■
If the electricity supply drops below 180 V, the electrical
ignition system does not work.
■
Any damage arising from the appliance being connected
incorrectly will invalidate the guarantee.
■
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
For the after-sales service
Caution!
■
The appliance must be connected in accordance with the
data on the rating plate.
■
Only connect the appliance to an electrical connection that
meets the applicable provisions. The socket must be easily
accessible so that you can disconnect the appliance from the
electricity supply if necessary.
■
Please ensure the availability of a multi-pin disconnecting
system.
■
Never use extension cables or multiple plugs.
■
For safety reasons, this appliance must only be connected to
an earthed connection. If the safety earth terminal does not
comply with regulations, safety against electrical hazards is
not guaranteed.
■
You must use a H 05 W-F type cable or equivalent for the
appliance connection.
Levelling the cooker
Always place the cooker directly on the floor.
1.
Pull out the plinth drawer and lift it up and out.
There are adjustable feet at the front and rear on the inside of
the plinth.
2.
Use an Allen key to raise or lower the adjustable feet as
necessary until the cooker is level (picture A).
3.
Push the plinth drawer back in (picture B).
Wall fixing
To prevent the cooker from tipping over, you must fix it to the
wall using the enclosed bracket. Please observe the installation
instructions for fixing the oven to the wall.
%
$
Содержание HGA223326Z
Страница 1: ... en Instruction manual Free standing cooker HGA223326Z ...
Страница 2: ......
Страница 26: ......
Страница 27: ......