Installation and connection
Electrical connection
The appliance must be connected to the mains by a licensed
expert. The regulations of your electricity supplier must be
observed.
Any damage arising from the appliance being connected
incorrectly will invalidate the guarantee.
Caution!
Your appliance comes with the enclosed cable for permanently
connecting it to the mains electricity supply.
Except in the event of damage, never remove the cable from
the appliance or replace it with another cable (with or without
plug).
Caution!
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in
order to avoid a hazard.
For the installer
■
An all-pole isolating switch with a contact gap of at least
3 mm must be present in the installation circuit. This is not
necessary if the appliance is connected by a plug that is
accessible to the user.
■
Electrical safety: The cooker corresponds to safety class I
and may only be used in conjunction with a safety earth
terminal.
■
A type H 05 VV-F or equally rated lead must be used to
connect the appliance.
Changing the intensity of the 13 / 16 / 20 Amp
connection current
Before using the hob for the first time, the intensity of the hob
connection must be tested.
Follow the steps below to change the current of the hob:
1.
Turn on the hob with the main switch. Do not place any pans
on the hotplates
2.
Within the following 60 seconds, adjust all hotplates to the
desired power level according to the required connection
current (see table).
3.
Turn off all the hotplates in sequence, starting from the lower
right and continuing counter-clockwise.
4.
The selected connection current is indicated in the display of
the right-hand lateral hotplates.
5.
Turn off the hob with the main switch.
The selected connection current will have been properly saved.
Wall fixing
To prevent the cooker from tipping over, you must fix it to the
wall using the enclosed bracket. Please observe the installation
instructions for fixing the oven to the wall.
D
E
F
G
Power level
Connection current in amperes
‚
20 A
ƒ
16 A
„
13 A
Содержание HCA628.2.U
Страница 1: ... en Instruction manual Free standing cooker HCA628 2 U ...
Страница 2: ......