English 13
The cabinet cavity must be plumb and the base must be flat
and level and capable of supporting a weight of at least 361
lbs (164 kg).
Single Oven, Undercounter 27”
Flush installation requires two side cleats to be attached
inside the cabinet frame, recessed from the front.
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4” space between the side of the
oven and the wall/door.
For oven support, install 2x4’s extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
The cabinet base must be flat and capable of supporting a
weight of at least 193 lbs (87 kg).
.
Dimensions for 30” Wall-Mounted Units
Single Oven 30”
*
For single ovens installed in a wall cabinet, the junction
box may be located above or beneath the unit within
reach of the power cable.
Flush installation requires two side cleats to be attached
inside the cabinet frame, recessed from the front.
It is good practice, when oven is installed at the end of a
cabinet run, adjacent to a perpendicular wall or cabinet
door, to allow at least 1/4” space between the side of the
oven and the wall/door.
For oven support, install 2x4’s extending front to back flush
with the bottom and the side of the opening. The supporting
base must be well secured to the floor/cabinet and level.
Note:
The conduit box must be installed either above or below the
unit. If the conduit box is installed below the unit, a 2”
diameter hole or space is required between the back wall
and the right rear of the 2x4 supports.
The cabinet cavity must be plumb and the base must be flat
and level and capable of supporting a weight of at least 212
lbs (96 kg).