6 720 819 528 (2016/02)
Therm 4000 S
Product details | 9
2.10 Specification
Technical features
Symbols
Units
GWH12
GWH15
GWH18
Performance
1)
1) 15 °C - 1013 mbar - dry: Natural gas 34.02 MJ/m
3
(9.5 kWh/m
3
)
GPL: Butane 45.65 MJ/kg (12.7 kWh/kg) - Propane 46.34 MJ/kg (12.9 kWh/kg)
Output capacity
Pn
kW
70973
86668
107824
Minimum output capacity
Pmin
kW
9895
12966
16378
Setting range
9895 -
70973
12966 -
86668
16378 -
107824
Heat input
Qn
kW
76773
93834
116013
Minimum heat input
Qmin
kW
10236
13649
17061
Efficiency at 100% of nominal load
%
92.0
92.0
92.0
Efficiency at 30% of nominal load
%
94.0
94
94
Data relating to the gas
Permissible gas supply pressure
Natural gas
G20
kPa
2
2
2
LPG
G30
kPa
2.8
2.8
2.8
Gas supply rate
Natural gas
G20
kg/h
2.4
2.9
3.6
LPG
G30
kg/h
1.8
2.2
2.7
Data relating to the water
Maximum admissible pressure
2)
2) Considering the effect of the dilation of the water, this value must not be exceeded
pw
psi
170
170
170
Minimum operating pressure
pwmin
psi
1.5
1.5
1.5
Start-up flow
l/min
2.2
2.2
2.2
Maximum flow, corresponding to a temperature increase of 35 °C
l/min
9.0
10.0
13.0
Ventilation circuit
Flow of combustion products
3)
3) For nominal output
kg/h
50
70
85
Temperature of the combustion gases at the test points
°C
170
170
170
Electrical circuit
Power supply voltage
V
230
230
230
Maximum power consumption
W
228
228
228
Appliance enclosure rating
IPX5D
General data
Weight (unpacked)
kg
10
11
12
Height
mm
568
568
568
Width
mm
300
300
364
Depth
mm
170
170
175
Table 6