![Bosch GMF 1600 CE Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/bosch/gmf-1600-ce/gmf-1600-ce_original-instructions-manual_47943021.webp)
English |
21
Bosch Power Tools
2 610 022 197 | (9.2.12)
Technical Data
Noise/Vibration Information
Measured sound values determined according to EN 60745.
Typically the A-weighted noise levels of the product are: Sound pressure level 86 dB(A); Sound power level 97 dB(A). Uncer-
tainty K =3 dB.
Wear hearing protection!
The vibration emission level given in this information sheet
has been measured in accordance with a standardised test
given in EN 60745 and may be used to compare one tool with
another. It may be used for a preliminary assessment of expo-
sure.
The declared vibration emission level represents the main ap-
plications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained,
the vibration emission may differ. This may significantly in-
crease the exposure level over the total working period.
An estimation of the level of exposure to vibration should also
take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may sig-
nificantly reduce the exposure level over the total working pe-
riod.
Identify additional safety measures to protect the operator
from the effects of vibration such as: maintain the tool and the
accessories, keep hands warm, organise work patterns.
Declaration of Conformity
We declare under our sole responsibility that the product de-
scribed under “Technical Data” is in conformity with the fol-
lowing standards or standardization documents: EN 60745
according to the provisions of the directives 2011/65/EU,
2004/108/EC, 2006/42/EC.
Technical file (2006/42/EC) at:
Robert Bosch GmbH, PT/ETM9,
D-70745 Leinfelden-Echterdingen
Robert Bosch GmbH, Power Tools Division
D-70745 Leinfelden-Echterdingen
25.01.2012
Assembly
f
Before any work on the machine itself, pull the mains
plug.
Inserting the Routing Motor into the Plunge
Base/Non-plunge Base (see figures A–B)
– Open the clamping lever for the plunge base/non-plunge
base
22
.
– Push the routing motor to the stop into the plunge base/
non-plunge base.
– When using the non-plunge base
3
, press clamping lever
25
and slide the routing motor
1
up or down to the desired
Multifunction Router
GOF 1600 CE
GMF 1600 CE
Article number
3 601 F24 0..
3 601 F24 0..
Rated power input
W
1600
1600
No-load speed
min
-1
10000 – 25000
10000 – 25000
Speed preselection
z
z
Constant electronic control
z
z
Connection for dust extraction
z
z
Tool holder
mm
inch
8 – 12
¼ – ½
8 – 12
¼ – ½
Plunge depth (plunge base)
mm
76
76
Weight according to EPTA-Procedure 01/2003
– Contour router
– Plunge router
kg
kg
–
5.8
4.3
5.8
Protection class
/
II
/
II
The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary.
Routing with
Non-plunge Base
Routing with
Plunge Base
Vibration total values a
h
(triax vector sum) and uncertainty K determined
according to EN 60745:
a
h
K
m/s
2
m/s
2
=6.0
=1.5
=5.5
=1.5
Dr. Egbert Schneider
Senior Vice President
Engineering
Dr. Eckerhard Strötgen
Engineering Director
PT/ESI