10
| English
d
180°
A
B
– Turn the measuring tool 180° without adjusting the
height. Aim it at wall A such that the vertical laser line runs
through the already marked point
Ⅰ
. Allow the measuring
tool to level in and mark the point where the laser lines
cross on wall A (point
Ⅲ
).
– The discrepancy
d
between the two marked points
Ⅰ
and
Ⅲ
on wall A reveals the actual height deviation of the
measuring tool.
The maximum permitted deviation on the measuring dis-
tance of 2 ×
5
m =
10
m is as follows:
10
m × ±
0.1
mm/m = ±
1
mm. The discrepancy
d
between
points
Ⅰ
and
Ⅲ
must therefore amount to no more than
1
mm.
Checking the levelling accuracy of the horizontal lines
For this check, you will need a free area of 5 ×
5
m.
– Mount the measuring tool in the middle between walls A
and B on a tripod
(24)
, or place it on a firm, level surface.
Switch on the measuring tool in the mode with automatic
levelling. Switch on horizontal mode with a laser line for-
wards and allow the measuring tool to level in.
2,5 m
5,0 m
5,0 m
5,0
m
5,0 m
A
B
– At a distance of 2.5 m from the measuring tool, mark the
centre of the laser line on both walls (point
Ⅰ
on wall A and
point
Ⅱ
on wall B).
2,5 m
d
5,0 m
2,5 m
5,0 m
A
B
– Set up the measuring tool at a 5 m distance and rotated
by 180° and allow it to level in.
– Align the height of the measuring tool (using the tripod or
by placing objects underneath as required) so that the
centre of the laser line exactly hits the previously marked
point
Ⅱ
on wall B.
– Mark the centre of the laser line on wall A as point
Ⅲ
(ver-
tically above or below point
Ⅰ
).
– The discrepancy
d
between the two marked points
Ⅰ
and
Ⅲ
on wall A reveals the actual horizontal deviation of the
measuring tool.
The maximum permitted deviation on the measuring dis-
tance of 2 ×
5
m =
10
m is as follows:
10
m × ±
0.1
mm/m = ±
1
mm. The discrepancy
d
between
points
Ⅰ
and
Ⅲ
must therefore amount to no more than
1
mm.
Checking the levelling accuracy of the vertical lines
For this check, you will need a door opening (on solid
ground) which has at least 2.5 m of space either side of the
door.
– Place the measuring tool 2.5 m away from the door open-
ing on a firm, flat surface (not on a tripod). Switch on the
measuring tool in the mode with automatic levelling.
Switch on vertical mode with a vertical laser line forwards
and aim the vertical laser line at the door opening. Allow
the measuring tool to level in.
1 609 92A 58T | (07.08.2020)
Bosch Power Tools