Technical Data
Line laser
GLL 3-15 X
Article number
3 601 K63 E..
Working range
A)
– Laser lines
15 m
– Plumb point
5 m
Laser line levelling accuracy
B)C)D)
±0.2 mm/m
Typical self-levelling range
±3°
Typical levelling time
< 4 s
Operating temperature
–10 °C to +45 °C
Storage temperature
–20 °C to +70 °C
Max. altitude
2000 m
Relative air humidity max.
90 %
Pollution degree according to
IEC 61010-1
2
E)
Laser class
2
Laser type
< 1 mW, 630−650 nm
C
6
1
Divergence
– Laser line
1.5 mrad
– Plumb point
1.5 mrad
Tripod mount
F)
5/8"
Batteries
4 × 1.5 V LR6 (AA)
Operating time approx.
C)
– With 1 laser line
24 h
– With 2 laser lines
14 h
– With 3 laser lines
10 h
Weight according to
EPTA‑Procedure 01:2014
0.54 kg
Dimensions (length × width × height)
– Without rotating platform
122 × 83 × 129 mm
– With rotating platform
Dia. 151 × 203 mm
Line laser
GLL 3-15 X
Protection rating (excluding bat-
tery compartment)
IP 54 (dust and splash-
proof)
A) The working range may be reduced by unfavourable environ-
mental conditions (e.g. direct sunlight).
B) ex-works
C) At
20–25
°C
D) The values stated presuppose normal to favourable environ-
mental conditions (e.g. no vibration, no fog, no smoke, no direct
sunlight). Extreme fluctuations in temperature can cause devi-
ations in accuracy.
E) Only non-conductive deposits occur, whereby occasional tem-
porary conductivity caused by condensation is expected.
F) Only available in combination with the rotating platform
The serial number
(4)
on the type plate is used to clearly identify your
measuring tool.
Assembly
Inserting/changing the batteries
It is recommended that you use alkaline manganese batter-
ies to operate the measuring tool.
To open the battery compartment cover
(3)
, press on the
locking mechanism
(2)
and remove the battery compart-
ment cover. Insert the batteries.
When inserting the batteries, ensure that the polarity is cor-
rect according to the illustration on the inside of the battery
compartment.
If the status display
(15)
flashes, the batteries have to be re-
placed.
Always replace all the batteries at the same time. Only use
batteries from the same manufacturer and which have the
same capacity.
u
Take the batteries out of the measuring tool when you
are not using it for a prolonged period of time.
The bat-
teries can corrode and self-discharge during prolonged
storage in the measuring tool.
Working with the Rotating Platform
(see figure A)
You can use the rotating platform
(12)
to rotate the measur-
ing tool 360° around a central, always visible plumb point.
This enables you to set up the laser lines precisely, without
having to change the position of the measuring tool.
Place the measuring tool on the rotating platform
(12)
so
that the fastening grooves
(13)
of the rotating platform fit
between the corresponding fastening grooves
(6)
on the
bottom of the measuring tool. Turn the measuring tool clock-
wise to lock it on the rotating platform.
Unscrew the legs of the rotating platform
(12)
with the
height adjustment screws
(10)
.
Roughly align the rotating platform using the spirit level
(8)
.
If the measuring tool is mounted on the rotating
platform
(12)
, you can use the fine adjustment screw
(11)
to align vertical laser lines precisely with reference points.
Bosch Power Tools