CHECK•LINE

®

                       BY ELECTROMATIC 

MODEL GE-50576-A

BELT TENSION TESTER

Operating Manual

 

Содержание GE-50576-A

Страница 1: ...CHECK LINE BY ELECTROMATIC MODEL GE 50576 A BELT TENSION TESTER Operating Manual ...

Страница 2: ...e microphone from GE 50576 A after use and place in the storage case Do not use the tool near flammable substances Do not use the tool near water or other liquids When performing the test in vehicle let the engine cool down before testing CAUTION Do not store in a humid area Do not place heavy objects on the GE 50576 A Do not wash the tool with liquid cleaners Wipe with a clean dry cloth Store the...

Страница 3: ...r component being serviced 1 1 Complete Kit The GE 50576 A is supplied as a complete kit that contains the components outlined in the table below and identified in the photo No Item No Description Model Name Specification 1 GE 50576 05 Li Ion Battery 3 7V 800mA 2 GE 50576 06 Storage Case Material Plastic Dimensions 160 x 100 x 60 mm 3 GE 50576 01 Accoustic Belt Tension Tester Dimensions approx 10 ...

Страница 4: ...e turned Off then back On 6 Charge LED Displays charge status Note If the unit is powered on while being charged via DC adapter or USB cable the charge LED turns green Red Charging Blinking Red Low Battery Green Charge complete 7 USB Connector USB connection port for charging firmware update 8 Update Button Depress the update button through the hole in the case when software updates are required 9...

Страница 5: ... 4 3 0 DISPLAY 3 1 Booting Screen 3 2 Main Screen 3 3 Set up Selection Screen 3 4 Min Max Range Setting ...

Страница 6: ...inimize background noise as much as possible during testing 5 Touch Start button on the screen or push Start button on the tester body The button image will change to a red square and a tone will sound 4 The Main Screen is displayed Place the microphone close to the belt approx 1cm without bending the microphone shaft excessively To ensure proper readings some values may need to be adjusted to red...

Страница 7: ...50576 A displays the result and calculated average 8 After three readings the start button image changes to again To re test touch the start button on the screen or push the mechanical start button on the tool body 9 GE 50576 A can be paused at any time during testing by touching the start button on the screen or pressing the mechanical start button on the tool body 10 To re set GE 50576 A touch o...

Страница 8: ...ccessful save Touch the right button to return to the default setting Touch the left button to return to the previous menu To re calibrate the touch screen touch the second button on the set up screen When a symbol appears on the display press the center of the After 5 steps for each corner and the center the display will return to the set up menu WARNING GE 50576 units are calibrated before shipm...

Страница 9: ...n a quiet area 3 If background noise causes interference touch the set up button and choose the Min Max setting menu 4 Adjust the min max range as follows Min Service information specification 100Hz Max Service information specification 100Hz 5 Perform the test again with normal background noise and adjust threshold again to a tighter range if background noise continues to be an issue Min Service ...

Страница 10: ... cable to the USB connector on the bottom of the tool body When connecting to the USB port the end of the cable should be inserted correctly to the lap top computer or USB hub Some regions may require a DC adapter In these regions connect the adaptor to the adaptor jack on the bottom of the tool body Note If the unit is powered on while being charged via DC adapter or USB cable the charge LED will...

Страница 11: ...service information for belt specifications After completing a testing session manually turn off the power disconnect the microphone from the tools and store it safely Charge the tool until charge LED turns to green To prevent possible damage remove the battery from the tool when storing GE 50576 A for an extended period of time time ...

Страница 12: ...ed Normal Charge Time 4 5 hours with USB port 2 3 hours with separate USB Charger 12V DC Operating Temperature 50 F to 122 F 10 C to 50 C Humidity 80 RH Scope of Delivery GE 50576 A Acoustic Belt Tension Tester touch pen microphone USB cable Rechargeable Li Ion Battery and protection cover in a portable zipper pouch Battery Warranty Six months Warranty One year Country of Origin South Korea No Cer...

Страница 13: ...RE RESULTING FROM THE USE OF SUPPLIED EQUIPMENT WHETHER SUCH DAMAGE OCCURS OR IS DISCOVERED BEFORE UPON OR AFTER REPLACEMENT OR REPAIR AND WHETHER OR NOT SUCH DAMAGE IS CAUSED BY MANUFACTURER S OR SUPPLIER S NEGLIGENCE WITHIN ONE YEAR FROM INVOICE DATE Some State jurisdictions or States do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not ...

Страница 14: ...ELECTROMATIC E Q U I P M E N T C O I N C 600 Oakland Ave Cedarhurst NY 11516 USA TEL 516 295 4300 FAX 516 295 4399 CHECK LINE INSTRUMENTS ...