1 689 979 894
2014-08-28
|
Robert Bosch GmbH
Technical data | FSA 720 | 27
en
8.1.5
Oszilloscope measuring functions
Measuring
functions
Measurement
range
1)
Sensors
Secondary voltage 5 kV – 50 kV
2)
Secondary sensor
Primary voltage
20 V – 500 V
2)
Primary connecting ca-
ble (UNI 4)
Voltage
200 mV – 200 V
2)
5 V – 500 V
2)
Multi measuring cable
CH1 / CH2
Measurement lead with
voltage divider
AC-coupling
200 mV – 5V
Connecting cable
B+/B–
Current
2 A
5 A
10 A
20 A
30 A
Current clamp 30 A
Current
50 A
100 A
200 A
1000 A
Current clamp 1000 A
1)
The test range is, depending on the zero line, positive or negative.
2)
The measuring range is greater than the permissible measurement
voltage
8.1.6
Oszilloscope functions and specifications
Function
Specification
Input coupling CH1/CH2
AC/DC
Input impedance CH1/CH2
(relativ to ground)
1 MOhm
Input impedance CH1/CH2
(galvanically insulated)
1 MOhm (5 – 200 V)
10 MOhm (200 mV – 2 V)
Input impedance CH2
(differentiell)
4 MOhm
Bandwidth CH1
(galvanically insulated)
> 5 kHz = 200 mV – 2 V
> 25 kHz = 5 V – 200 V
Bandwidth CH1 (relativ to ground) > 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
Bandwidth CH2 (relativ to ground) > 1 MHz = 200 mV – 2 V
> 5 MHz = 5 V – 200 V
Bandwidth Measurement lead with
voltage divider
> 500 kHz
Bandwidth CH2
(differential measurement)
> 30 kHZ
Bandwidth 1000 A current clamp
> 1 kHz
Bandwidth 30 A current clamp
> 50 kHz
Bandwidth Secoundary sensor
> 1 MHz
Bandwidth
Primary connecting cable (UNI 4)
> 100 kHz (20 V)
> 1 MHz (50 V – 500 V)
Time ranges (relative to 500 scan-
ning points)
10 µs – 100 s
Time ranges (relative to 1 scanning
point)
20 ns – 200 ms
Time basis accuracy
0,01 %
Vertical accuracy
Device without sensors
±2 % of reading
±0,3 % of measuring range
(Offset error for ranges >
1 V) or ±5 mV
(Offset error for
ranges 200 mV – 1 V)
Vertical resolution
10 bit
Function
Specification
Memory depth
1 Mega scan values or 50
curves
Scan rate per channel
50 Ms/s
8.2
Signal generator
Function
Specification
Amplitude
-10 V – 12 V
(Load < 10 mA) to ground
Signal shapes
DC, sinus, triangle, square
Frequency range
1 Hz – 1 kHz
Output current
max. 75 mA
Impedance
approx. 60 Ohm
Symmetry
10 % – 90 % (triangle, square)
Curve generation
Output rate up to 100000 values/s,
Resolution 8 bit,
Y-full range adjustable ( bit),
Unipolar / bipolar mode
Short-circuit resistance
to interference voltage
< 50 V static
Short-circuit resistance
to interference voltage
< 500 V / 1 ms dynamic
R
Automatically switched filter and damping elements
for improvement of signal quality.
R
Automatic cutoff for short circuit, interference volt-
age detection at start of signal generator.
8.3
Power pack
Function
Specification
Input voltage
90 VAC – 264 VAC
Input frequency
47 Hz – 63 Hz
Output voltage
15 V
Operating temperature
0 °C – 40 °C
8.4
Noise emission
< 70 dB(A)
8.5
Dimensions and weights
Function
Specification
Dimensions H x W x D:
180 x 550 x 200 mm
Weight
8 kg