52
53
Flash and fault codes, information about how to reset the Twinguard to
its factory settings plus much more can be found in the online FAQs at
www.bosch-smarthome.com/faq
In normal operation, LED 1 and LED 2 of the Gateway are continuously
lit up green. LEDs 3, 4 and 5 are inactive in this case.
10.0 ALARM AND TROUBLESHOOTING
10.1 Gateway faults
10.2 Twinguard faults
Visual
signal
Cause
Measure
No LED
is lit up
USB power cable not
connected / power
cable faulty / Gateway
faulty
Check the power supply to the power
cable; replace the power cable or
Gateway if necessary
LED 2
is lit up
orange
Internet connection not
available;
Cloud not available
Call the hotline
LED 2
is lit up
red
Internet connection not
available;
Cloud not available
Check the connection between the
Gateway and the DSL router
or check the internet connection of
the DSL router
Audible
signal
Visual
signal
Cause
Measure
Quiet
signal,
every 43 s
Yellow LED
flashes 3
times
every 43 s
Alarm faulty
Replace the Alarm
Quiet
signal,
every 300 s
Yellow LED
flashes
once
every 300 s
Batteries nearly empty
Replace the batteries
Quiet
signal,
sounds
every hour
–
Alarm OK, but
batteries in one of the
other alarms in the
network are nearly
empty
Look for a alarm whose
360° circumferential
LED light strip is flashing
yellow (once every 300 s)
and replace its batteries