15
5. CAMERA RE-ASSEMBLY
If changes were necessary due to voltage and
installation requirements, make sure all power
and video wires are correctly connected and
tightened into their terminal blocks.
Step 5.1 - Connect a ¾” NPT gland or conduit
to the open side of the base: Note:
The gland and conduit is not
supplied.
Step 5.2 - Push the external power/video cable
into the housing and connect to the
power and video of the circuit board.
Step 5.3 - Check that the large “
O
” ring gasket
at bottom of the Camera Base
threads is undamaged.
Step 5.4 - Make sure the “
Top
” edge of the
VRB/Camera/LED Chassis is
aligned correctly with the Base.
Refer to
Figure 5-1
on page 17.