Bosch Security Systems
Quick Install
MAN30IPB Rev.0
2.7
Window Selection
2.8
LED array- power adjustments
If adjustment is needed, the following procedure must be followed:
1) Remove the rear cover of the camera. Set cover aside.
!
CAUTION!
The CCD image sensors are highly sensitive and require
special care for proper performance and extended lifetime. Do not
expose them to direct sunlight or bright spot lights in operating and
non-operating conditions.
Recommended
focal length [mm]
Recommended HFOV @ 100ft /
30m distance [ft / m]
Narrow Window
18-50mm
28ft / 8m and narrower
Wide Window
5-18mm
Wider than 18ft / 8m
IR Adjustment
Pot
Photocell
Adjustment Pot