5
2.3
Test equipment for customer service
1 siphon, water gauge 100 cm, inside diameter max. 8 mm
1 flow meter (variable-area type), measuring range 1.0 l/min.
to 10 l/min., measuring medium air, 20 °C, 1 bar absolute
1 absolute-pressure sensor (barometer) or adjusting barometer
set to absolute pressure. Measuring accuracy 5 Hpa (5 mbar)
1 gas-wash bottle (bead bottle)
1 digital multimeter (DMM)
1 oscilloscope, sensitivity 5mV/cm
1 thermometer with surface probe
1 P100 or P200 or P140 for engine-speed measurement
1 DC calibrator, 0 to 15 mV
1 data terminal (pocket keypad)
1 measured-value printer (integrated or connected externally via
serial interface)
Viton hose to test-gas connection (do not use any other type of
hose material)
Compressed air for cleaning test-gas probe and hose
2.4
Test gases for customer service
(with manufacturer's certificate)
In order to save on bottles of test-gas, mixed gases are sometimes
recommended.
No.1: 14 % CO
2
Accuracy of analysis ± 1 %
No.2: 16.000 ppm C
3
H
8
(propane)*)Accuracy of analysis ± 1 %
No.3: 9 % CO
Accuracy of analysis ± 1 %
No.4: 5 % CO + 7.5 % CO
2
+
2.000 ppm C
3
H
8
(propane)*) Accuracy of analysis ± 1 %
No.5: 2 % CO +
3.800 ppm C
3
H
8
(propane)*) Accuracy of analysis ± 1 %
No.6: 8.000 ppm C
3
H
8
(propane)*) +
1 % CO
Accuracy of analysis ± 1 %
In some countries, A and B are used for the calibration of test
gases in accordance with OIML Directive R99. These gases may
also be used for the purpose of fine-tuning. In this case, gases no.
1 and 4 need not be used.
A
2.000 ppm C
3
H
8
(propane)*) Accuracy of analysis ± 1 %
3.5 % vol. CO
Accuracy of analysis ± 1 %
14 % CO
2
Accuracy of analysis ± 1 %
B
200 ppm C
3
H
8
(propane)*)
Accuracy of analysis ± 1 %
0.5 % vol. CO
Accuracy of analysis ± 1 %
6 % CO
2
Accuracy of analysis ± 1 %
*) The exhaust-gas analyzer is fine-tuned regularly with propane
(instead of hexane) for practical reasons. During fine-tuning,
the exhaust-gas analyzer is informed of the concentration of the
test gas in
"ppm propane"
. The exhaust-gas analyzer auto-
matically takes account of the necessary "propane factor".
Содержание ETT 008.31
Страница 1: ...1 Repair instructions Exhaust gas analyzer ETT 008 31 ETT 008 38 ...
Страница 48: ...48 8 15 5 Sensor board component location diagram ...
Страница 51: ...51 8 17 1 Motherboard component location diagram ...
Страница 61: ...61 12 Diagrams circuit diagrams and gas route diagram 12 1 Circuit diagram 1 ...
Страница 62: ...62 12 2 Circuit diagram 2 ...
Страница 63: ...63 12 3 Gas route diagram ...
Страница 65: ...65 ...