Bosch Security Systems | 2003-11
Eazeo DVR
| Installation Manual | Chapter 4
EN
| 12
4
Menu set-up
When system has been connected as described:
•
Switch power on
•
The display lights if power is normal.
•
Allow some time for the system to load.
•
Press the MENU key to enter the MAIN MENU.
When the main menu is displayed you see the different
submenus where the settings can be changed.
To navigate through these menus, turn the Jog Dial
clockwise or counterclockwise to scroll through the
submenus. Press the ENTER key to open a submenu. In
the submenus, continue using the Jog Dial and ENTER
key to scroll through items and values and select them.
To return to the main menu, scroll to the bottom of each
submenu to the MAIN MENU item and select it by
using the ENTER key.
4.1 Main menu
4.2 Clock/Language menu
DATE: Year: 2000~2099 Month: 01~12 Date: 01~31
TIME: Hour: 00~23 Minute : 00~59 Second: 00~59
DATE FORMAT: Set the display order for Year (YYYY), Month (MM)
and Day (DD)
MENU LANGUAGE: English, German, French, Spanish, Italian,
Portuguese, Dutch or Polish.
MAIN MENU: Return to the main menu.
4.3 Normal record menu
SPEED : Select the record speed from 0.1 to 25/30 IPS.
QUALITY: There are six quality levels for recording
LOWER 15 KB
LOW: 20 KB
BASIC: 25 KB
STANDARD: 30 KB
HIGH: 35 KB
SUPERIOR: 40 KB
MULTIPLEXER:
Select Multiplexer connection or one camera connection
ON : The video input from MUX MAIN MONITOR connector
at the rear panel is looped through to the MONITOR OUT
when the recorder is not in MENU mode.
OFF : The main monitor output is same as video out
connector all the time.
VEXT: There are two modes for Time lapse recording, 1 FIELD (1, 2,
3, 4, 5 etc.) or 2 FIELDS of the same camera (1, 1, 2, 2, 3, 3,
4, 4, 5, 5 etc.).
DISK FULL:
STOP : When disk is full, the machine stops recording.
REWRITE : When disk is full, the current video overwrites the
existing video from the beginning of the hard disk.
4.4 Alarm record menu
ALARM OPERATION:
ON : Record when alarm occurs.
OFF : Do not record when alarm occurs.
RECORD SPEED: Recording speed for the duration of the alarm.
The max. recording speed is 25/30 IPS (PAL/NTSC).
The min. recording speed is 0.1 IPS.
MAIN MENU
CLOCK/LANGUAGE >
NORMAL RECORD >
ALARM RECORD >
TIMER >
BUZZER >
ARCHIVE >
NETWORK >
SYSTEM SETTING >
CLOCK/LANGUAGE MENU
DATE
2002-04-24
TIME
13:01:02
DATE FORMAT
YYYY-MM-DD
MENU LANGUAGE
ENGLISH
MAIN MENU >
NORMAL RECORD MENU
RECORD SPEED
10 IPS
RECORD QUALITY
STANDARD
MULTIPLEXER
ON
VEXT
1 FIELD
DISK FULL
REWRITE
MAIN MENU >
ALARM RECORD MENU
ALARM OPERATION
ON
RECORD SPEED
25 IPS
RECORD QUALITY
STANDARD
ALARM-IN TYPE
N.O.
ALARM-RESET TYPE
N.O.
ALARM DURATION TIME
10 SECS
PRE-ALARM OPERATION
ON
RECORD SPEED
25 IPS
MAIN MENU
>