ARP Command Usage 

1.

 

Open a DOS window from the Start menu by 
selecting Start 

 Run. 

2.

 

At the Run dialog box, type COMMAND and 
click 

OK

A DOS window appears. 

3.

 

Type the following at the DOS command line:  

arp –s 172.17.10.70 00-20-4a-12-04-

0e

 [ENTER] 

172.17.10.70 would be the example IP address 
given from the Network Administrator and 00-20-
4a-12-04-0e would be the example MAC hardware 
address from DX4020. 

If following your command the computer responds 
with a prompt (as shown to the right) then the 
address was accepted. 

 

There is no indication that the operation is 
performed properly. The absence of an 
error message is your indication that the 
function was correct. 

4.

 

Verify that the IP address was correctly entered 
into the ARP table by typing: 

arp -g

 [ENTER] 

Figure 15:  arp -g 

 

 

This shows the Internet address (IP ADDRESS) 
and the corresponding Physical Address (MAC 
hardware address). The third line of the table in 
Figure 15 shows that the arp contains a MAC 
address of 00-20-4a-51-19-8c temporarily linked to 
IP address 172.17.10.70. 

The network uses this table to identify devices and 
route signals. The number of devices and other 
“types,” like “dynamic,” depends on the network 
and the number and type of devices that this PC 
has corresponded with. You must identify the 
MAC address of the device you are installing and 
verify that it now has an IP address linked to it. 

6.5 

Using Telnet to Finish the 
Configuration 

If you are using Windows 95/98, see Section 6.5.1 Using 
Windows 95/98 Telnet

If you are using Windows 2000/XP, see Section 6.5.2 
Using Windows 2000/XP Telnet

6.5.1 

Using Windows 95/98 Telnet 

1.

 

Open a DOS window from the Start menu by 
selecting 

Start 

 Run

2.

 

At the Run dialog box, 

telnet

 [ENTER]. 

The Telnet application starts. 

3.

 

Select 

Connect

 

 Remote System...

 

 

The Connect window displays. 

 

4.

 

Type the IP address of the DX4020 (this is the IP 
address that was assigned to the DX4020 in the 
previous section) in the Host Name field.  

In this example, the IP address is 172.17.10.70. 
Type 

1

 into the Port field and leave the TermType 

field at 

vt100

 

Содержание DX4020-EXP

Страница 1: ...EN Installation Guide Network Interface Module DX4020 EXP ...

Страница 2: ...ations over Ethernet networks Typical uses include PC front end software packages such as PC9000 Remote Programming Software RPS connection for control panel programming diagnostic troubleshooting D6600 Central Station Receiver CSR reporting and or history retrieval Figure 1 DX4020 Network Interface Module 1 3 2 4 5 6 1 Lantronix Xport NIM 2 EPROM 3 Data Bus 4 DIP Switches 5 Serial Bus LEDs 6 P2 J...

Страница 3: ...ter Compatibility DS7400xi 4 10 or later Default IP Address 0 0 0 0 DHCP mode 2 2 System Overview See Figure 2 for a general system connection of the following devices a compatible Bosch Security Systems control panel a DX4020 Network Interface Module a D6600 Receiver and a D6680 Network Adapter Figure 2 System Connections Overview 7 3 4 6 1 2 5 7 8 9 9 10 1 Compatible Bosch Control Panel 2 DX4020...

Страница 4: ...ation for complete mounting instructions Figure 3 DX4020 Mounting Holes 1 1 DX4020 Mounting Holes 3 2 DX4020 Wiring Wiring connections are made from the DX4020 s data bus terminals to the compatible control panel s data bus terminals See the control panel s documentation for complete wiring instructions Figure 4 one column wide figure This figure box is saved as a AutoText entry called Figure Colu...

Страница 5: ...5 6 7 8 1 2 1 OPEN UP Position 2 CLOSED DOWN Position Figure 7 DIP Switch Settings for Address 88 OPEN 1 2 3 4 5 6 7 8 1 2 1 OPEN UP Position 2 CLOSED DOWN Position 4 2 DIP Switch Address Settings for the DS7240V2 DS7220V2 Control Panels The DS7240V2 and DS7220V2 control panels require firmware revision 2 xx or later for network communication Set the DX4020 s DIP Switch address to 134 when using t...

Страница 6: ...le jumper on or disable jumper off LED operation Figure 11 DX4020 Ethernet Serial LEDs 1 3 4 2 1 Ethernet Serial LED Location 2 P2 Jumper Location 3 LED Enable Jumper On Position 4 LED Disable Jumper Off Position Table 2 DX4020 Bus Serial Status LED Functions LED Name Color Function 1 BUS XMIT Red Flashes when the data bus sends a message 2 BUS RCV Red Flashes when the data bus receives a message ...

Страница 7: ...plex Activity 6 IP Programming Use this section to set up the initial IP address so that the DX4020 can be set with a Network IP address The setup consists of using resident commands and programs such as the commands ARP and Ping and the program Telnet available in the Microsoft Windows operating system The IP MAC address and port number used here are for demonstration only A working knowledge of ...

Страница 8: ...ke sure there is power to the DX4020 and the Ethernet Network RJ 45 connection is in place To telnet into the configuration program the PC used to configure the DX4020 and the DX4020 itself must both be on the same gateway the device that connects the LAN to the WAN Use telnet to communicate with the DX4020 and establish its communications configuration parameters Once the DX4020 is configured and...

Страница 9: ...ress The third line of the table in Figure 15 shows that the arp contains a MAC address of 00 20 4a 51 19 8c temporarily linked to IP address 172 17 10 70 The network uses this table to identify devices and route signals The number of devices and other types like dynamic depends on the network and the number and type of devices that this PC has corresponded with You must identify the MAC address o...

Страница 10: ...Mode you are disconnected If you are disconnected the following message displays 8 If you pressed ENTER within 5 seconds of seeing the Press Enter to go into Setup Mode message you should see the following screen 9 Press 0 then ENTER to set up the basic Server configuration If the DX4020 Network Interface Module was programmed with an IP address in the past it is displayed in parentheses as shown ...

Страница 11: ... 0 9 255 255 254 0 25 254 0 0 0 10 255 255 252 0 26 252 0 0 0 11 255 255 248 0 27 248 0 0 0 12 255 255 240 0 28 240 0 0 0 13 255 255 224 0 29 224 0 0 0 14 255 255 192 0 30 192 0 0 0 15 255 255 128 0 31 128 0 0 0 16 255 255 0 0 12 If using DHCP the following appears If you want to assign a name for this device for use on a LAN type Y and enter up to 16 characters and ENTER Otherwise just press ENTE...

Страница 12: ...IP address 22 Enter the same port number that was used for the D6680 23 To enable encryption select 6 Security from the main menu and follow the next steps If encryption is enabled on the DX4020 it must be enabled at the D6680 E120 with the same key The software revision of the Network Interface Module attached to the DX4020 must be 1 5d or greater To check the version telnet the unit and the vers...

Страница 13: ...rt menu by selecting Start Run 2 Type COMMAND and click OK at the Run dialog box A command prompt window appears The colors have been inverted here for clarity The normal prompt window appears with white text on black 3 Type in telnet and press ENTER at the C prompt 4 Type open space IP ADRESS space PORT NUMBER at the Microsoft Telnet prompt For example open 172 17 10 70 1 The connection fails the...

Страница 14: ...h Security Sys 8 04 F01U002192B 7 Control Panel Programming See the control panel s documentation for DX4020 to control panel programming 8 Listings and Approvals The DX4020 Network Interface Module is listed for the following FCC Part 15 Radiated Conducted Emissions CE ...

Страница 15: ...DX4020 EXP Installation Guide Notes EN 15 Bosch Security Sys 8 04 F01U002192B Notes ...

Страница 16: ... 2004 Bosch Security Systems Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 Customer Service 800 289 0096 Technical Support 888 886 6189 F01U002192B ...

Отзывы: