background image

en

    Installation

16

Wall-mounting the appliance and levelling it

1.

First remove the protective film from the back of the 

appliance and, following installation, remove the rest 

of the film.

2.

When mounting the appliance, ensure that it 

engages properly with the mounting supports.

3.

If required, the appliance can be moved to the right 

or to the left.

4.

Firmly tighten the screws for the mounting supports. 

Hold the bracket firmly when doing so. 

¨

5.

If no duct is to be fitted, screw in the two locking 

screws without the bracket. 

©

Connecting the pipes

If the extractor hood is to be operated in exhaust-air 

mode, the pipes must be connected. If the extractor 

hood is to be operated in air-recirculation mode, an 

optional accessory must be fitted. To do this, refer to 

the installation instructions provided.

Note: 

If an aluminium pipe is being used, smooth the 

connection area beforehand.

Exhaust air pipe, dia. 150 mm (recommended size)

Fit the exhaust air pipe directly to the air-pipe connector 

and seal the joint.

Exhaust air pipe, dia. 120

 

mm

1.

Fit the reducing connector directly to the air-pipe 

connector.

2.

Attach the exhaust air pipe to the reducing 

connector. 

3.

Use suitable means to seal both joints.

Attaching the flue duct

If the extractor hood is to be operated in exhaust-air 

mode, a flue duct must be fitted. 
The flue duct does not need to be fitted for air-

recirculation mode.

:

Warning – Risk of injury! 

From sharp edges during installation. Always wear 

protective gloves while installing the appliance.

:

Warning – Risk of electric shock! 

Components inside the appliance may have sharp 

edges. These may damage the connecting cable. Do 

not kink or pinch the connecting cable during 

installation.

1.

Separate the flue duct sections by removing the 

adhesive tape. 

2.

Remove the pieces of protective film from both flue 

duct sections.

3.

Push one flue duct section into the other.

Notes

– To prevent scratches, lay paper over the edges of 

the outer flue duct section to protect the surface.

– The slots of the inner flue duct section point 

downwards.

4.

Place flue ducts sections on the appliance.

5.

Slide the inner flue duct section upwards, attach it to 

the left and right sides of the retaining bracket, and 

then slide it down to engage it. 

¨

6.

Screw the flue duct section to the sides of the 

retaining bracket using two screws. 

©

7.

Clip the lower flue duct section in at the retaining 

bracket. The connection cable must not be 

damaged. 

ª

Note: 

If an air-recirculation optional accessory has been 

fitted and the extractor hood is to be operated without a 

flue duct, the cable must be wound onto the connector.

Содержание DWK67CM60

Страница 1: ...3FHJTUFS ZPVS OFX EFWJDF PO Z PTDI OPX BOE HFU GSFF CFOFGJUT CPTDI IPNF DPN XFMDPNF en Instructions for installation and use Extractor hood ...

Страница 2: ... This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres above sea level This appliance may be used by chi...

Страница 3: ...In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode Warning Risk of fire Fatty deposits in the grease filter may catch fire Regularly clean the grease filter Neve...

Страница 4: ... are dangerous Repairs may only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Causes o...

Страница 5: ...onmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible...

Страница 6: ...g The lighting can be switched on and off independently of the fan Touch the B symbol 2Cleaning and maintenance Cleaningandmaintenance Warning Risk of burns The appliance becomes hot during operation Allow the appliance to cool down before cleaning Warning Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull ou...

Страница 7: ...he metal grease filters in hot soapy water Clean the filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing dete...

Страница 8: ...les replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only Warning Risk of injury The light emitted ...

Страница 9: ...ns in the accessory E no FD no After sales serviceO GB 0344 892 8979 Calls charged at local or mobile rate IE 01450 2655 0 03 per minute at peak Off peak 0 0088 per minute 1U 1U 7 SH Accessories Order number Starter set for air recirculation mode flat hood with chimney Easy change filter for starter set DWZ0AF0U0 DWZ0AF0A0 Starter set for air recirculation mode flat hood without chimney Easy chang...

Страница 10: ... hood is to be operated in air recirculation mode an optional accessory must be fitted To do this refer to the installation instructions provided The flue duct does not need to be fitted for air recirculation mode For additional optional accessories refer to the installation instructions provided The surfaces of the appliance are sensitive Avoid damaging them during installation PLQ PP PLQ PP PD P...

Страница 11: ...tion location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Warning Risk of fire Fatty deposits in the grease filter may catch fire The speci...

Страница 12: ...al vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire...

Страница 13: ...l KGeneral information GeneralinformationChecking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structures e g plasterboard porous concrete poroton bricks The max...

Страница 14: ...hood should be positioned and lightly mark where the lower edge of the appliance should be on the wall Determine where the middle should be based on the hob Note We recommend fitting the extractor hood such that the lower edge of the glass screen is in line with the lower edges of the adjacent wall hung cabinets Make sure that the specified safety clearances from the hob are complied with 2 Place ...

Страница 15: ...hout a flue duct Installation Screw in the mounting supports for the extractor hood until they are hand tight use a spirit level to level the appliance and then screw the mounting supports in fully PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Страница 16: ...ints Attaching the flue duct If the extractor hood is to be operated in exhaust air mode a flue duct must be fitted The flue duct does not need to be fitted for air recirculation mode Warning Risk of injury From sharp edges during installation Always wear protective gloves while installing the appliance Warning Risk of electric shock Components inside the appliance may have sharp edges These may d...

Страница 17: ...6 ...

Страница 18: ...6 ...

Страница 19: ...6 ...

Страница 20: ...MJBODFT 4FSWJDF SFF BOE FBTZ SFHJTUSBUJPO o BMTP PO NPCJMF QIPOFT XXX CPTDI IPNF DPN XFMDPNF PPLJOH GPS IFMQ PV MM GJOE JU IFSF YQFSU BEWJDF GPS ZPVS PTDI IPNF BQQMJBODFT OFFE IFMQ XJUI QSPCMFNT PS B SFQBJS GSPN PTDI FYQFSUT JOE PVU FWFSZUIJOH BCPVU UIF NBOZ XBZT PTDI DBO TVQQPSU ZPV XXX CPTDI IPNF DPN TFSWJDF POUBDU EBUB PG BMM DPVOUSJFT BSF MJTUFE JO UIF BUUBDIFE TFSWJDF EJSFDUPSZ 3PCFSU PTDI BV...

Отзывы: