background image

9

en

Installation Instructions:
Important information

Additional information concerning gas cookers:

 

When installing gas hotplates, comply with the 

relevant national statutory regulations (e.g. in Ger-

many: Technische Regeln Gasinstallation TRGI).

 

Always comply with the currently valid regula-

tions and installation instructions supplied by the 

gas appliance manufacturer.

 

Only one side of the extractor hood may be 

installed next to a high-sided unit or high wall. Gap 

at least 50 mm.

 

Minimum distance on gas hotplates between 

the upper edge of the trivet and lower edge of the 

extractor hood: 

400 mm.

 

Old appliances are not worthless rubbish. Valu-

able raw materials can be reclaimed by recycling old 

appliances. Before disposing of your old appliance, 

render it unusable.

 

You received your new appliance in a protective 

shipping carton. All packaging materials are environ-

mentally friendly and recyclable. Please contribute 

to a better environment by disposing of packaging 

materials in an environmentally-friendly manner.
Please ask your dealer or inquire at your local au-

thority about current means of disposal.

 

The extractor hood can be used in exhaust air 

or circulating air mode.

 

Always mount the extractor hood over the cen-

tre of the hob.

 

Minimum distance between electric hob and 

bottom edge of extractor hood: 

400 mm.

 

The extractor hood must not be installed over 

a solid fuel cooker – a potential fire hazard (e.g. fly

-

ing sparks) – unless the cooker features a 

closed, 

non-removable cover 

and all national regulations 

are observed.

 

The smaller the gap between the extractor hood 

and hotplates, the greater the likelihood that drop-

lets will form on the underside of the extractor hood.

Содержание DWK096751B

Страница 1: ...Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 14 Min DTAG DWK096751B en Operating and installation instructions ...

Страница 2: ......

Страница 3: ...n conveyed back into the kitchen The grease filter absorbs the grease particles in the kitchen vapours The activated carbon filter binds the odorous substances If no activated carbon filter is installed it is not possible to bind the odorous substances in the cooking vapours Lighting Light fan switches Ducting panels Chimney Operating modes Exhaust air mode The extractor hood fan extracts the kitc...

Страница 4: ...ood is situated over a gas hob operate the hood at maximum setting if three or more gas hotplates are operated simultaneously Safety instructions Do not flambé food directly under the extractor hood Risk of grease filter catching fire due to flames The hotplates must always be covered with a utensil Restrictions apply to the use of the extractor hood over a solid fuel burner coal wood etc See Inst...

Страница 5: ...t shows H E By pressing this key it is possible to set the delayed shutdown of the appliance to 30 minutes This function is suitable for a complete elimination of the residual smells It can be activated at any position and it is deactivated by pressing the key again or by switching off the motor The point low to right flashes F With a short press turns light on and off With an ex tended press turn...

Страница 6: ...ducting panels Remove the filters one by one Ducting panels The ducting panels must never be washed in a dishwasher Open the ducting panels pulling them down wards Disconnect the panels from the hood canopy by sliding the fixing pin lever Any kind of bending of the filters has to be avoided when washing them Before fitting them again into the hood make sure that they are completely dry The colour ...

Страница 7: ...connection press and hold B key When releasing the key two rotating rectangles appear on the display Within 3 seconds press the B key until a flash ing confirmation appears on the dispaly 2 flashes with C sign charcoal filter satu ration alarm ACTIVATED 1 flash with C sign charcoal filter satura tion alarm DEACTIVATED Replacing the activated carbon filter Reset of the alarm signal Switch off the h...

Страница 8: ...aning agent Do not use aggressive acidic or caustic clean ers Do not use abrasive agents Replacing the light bulbs 1 Switch off the extractor hood and pull out the mains plug or switch off the electricity supply at the fuse box When switched on the halogen bulbs become very hot Even for some time after the bulbs have been switched off there is still a risk of burns 2 With the aid of a screwdriver ...

Страница 9: ...pliance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environ mentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local au thority about current means of disposal The extractor hood can be used in...

Страница 10: ...an be achieved if combustion air can flow through non lockable openings e g in doors win dows and via the airintake exhaust air wall box or by other technical measures such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting...

Страница 11: ...erminal in the plug marked E or with the symbol or coloured green or green and yel low 2 Connect the blue Neutral wire to the terminal in the plug marked N or coloured black 3 Connect the brown Live wire to the terminal marked L or coloured red The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations If possible site the earthed soc...

Страница 12: ...imum distance between the hob and the extractor hood is maintained 400 mm for the electric or gas hob 4 Drill ø 8 mm holes A and B for the extractor hood Drill ø 8 mm holes C for the chimney brackets 5 Insert plugs 11 into the holes so that they are flush with the wall 6 Fix the brackets 7 2 1 using the 12a screws supplied In case of hood installation in recycling ver sion with the chimney the upp...

Страница 13: ...ert the connection extension pieces laterally 14 1 in connection 15 Make sure that the outlet of the extension pieces 14 1 is horizontally and vertically aligned with the chimney outlets Connect the air outlet connection 15 to the hood body outlet using either a pipe ø 150 mm Chimney assembly Upper Chimney Slightly widen the two sides of the upper Chim ney and hook them behind the brackets 7 2 1 m...

Страница 14: ...Notizen Notes Note Notulen Notas σημείωση ...

Страница 15: ...DHZ5475 ...

Страница 16: ...Robert Bosch Hausgeräte GmbH 436004612_01 090218 ...

Отзывы: