11.0 Optical Module Adjustment

The PIR zones of the DS939 are divided into three groups. Each of these 3 groups can be independently adjusted vertically to provide the best
coverage within a room.

              Only two coverage patterns are shown for clarity.

PIR vertical adjustment knobs 

Use the following chart to adjust the optical modules based on the mounting height of the detector. The range shown is the distance from the detector
to the outside edge of the coverage pattern.

Mounting Height

Feet (Meters)

Maximum

Range

Feet (Meters)

8 (2.4)  10 (3)   12 (3.7)   14 (4.3)   15 (4.6)   16 (4.9)  18 (5.5)   20 (6.1)   22 (6.7)   24 (7.3)   25 (7.6)

10 (3)

C

A

15 (4.6)

G

D

A

A

20 (6.1)

I

G

D

B

A

A

25 (7.6)

I

F

E

D

C

A

A

30 (9.1)

H

F

E

E

C

B

A

35 (10.7)

I

G

G

F

E

C

B

A

A

In installations where a targeted coverage is required for part of the area, the optical modules must be adjusted for the correct coverage. In the
example below, the detector is mounted 12 ft. (3.7 m) above the floor. The distance to one wall is 20 ft. (6.1 m) and 35 ft. (10.7 m) to the opposite wall.
Using the chart above, the optical module for the 20 ft. (6.1 m) range was set to "D" and the optical  module for the 35 ft. (10.7 m) was set to "I".

Only two coverage patterns are shown for clarity.

Содержание DS939

Страница 1: ... C For UL Listed Requirements the range is 32 to 120 F 0 to 49 C US Patent This detector is protected by one or more of the Numbers following 4 764 755 Other patents pending Compliance This device complies with Part 15 of the FCC Rules and with RSS 210 of Industry and Science Canada Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this dev...

Страница 2: ...ly NO C NC T T M ALARM TAMPER POWER Terminals 1 2 Power limits are 9 to 15 VDC Use no smaller than 22 AWG 0 8 mm wire pair between the unit and the power source Terminals 3 NO 4 C 5 NC Alarm relay contacts rated 125 mA 28 VDC maximum for DC resistive loads Use terminals 4 5 for Normally Closed circuits Do not use with capacitive or inductive loads Terminals 6 T 7 T Normally Closed tamper contacts ...

Страница 3: ...e Walk Test if OFF ON for more than 5 seconds but less than 20 seconds OFF Turn OFF Remote Walk Test if ON ON for more than 1 second but Less than 20 seconds OFF 8 2 Anti Vandal Screw After the cover has been closed the entire assembly can be secured together using the supplied anti vandal screw 8 3 Maintenance At least once a year the range and coverage should be verified To ensure continual dail...

Страница 4: ...ing height of the detector The range shown is the distance from the detector to the outside edge of the coverage pattern Mounting Height Feet Meters Maximum Range Feet Meters 8 2 4 10 3 12 3 7 14 4 3 15 4 6 16 4 9 18 5 5 20 6 1 22 6 7 24 7 3 25 7 6 10 3 C A 15 4 6 G D A A 20 6 1 I G D B A A 25 7 6 I F E D C A A 30 9 1 H F E E C B A 35 10 7 I G G F E C B A A In installations where a targeted covera...

Отзывы: