Region
Certification
Australia
RCM
[DS938Z]
Europe
CE
2004/108/EC EMC Directive (EMC);
2006/95/EC Low-Voltage Directive
(LVD); 2011/65/EU Restriction of the
[DS938Z][DS938Z-FRA]
EN5013
1
EN50131-2-4, Grade 2 [DS938Z-FRA]
USA
UL
DS938Z: ANSR: Intrusion Detection
Units (UL639)
UL
ZX938Z: ANSR: Intrusion Detection
Units (UL639)
France
AFNOR
260001760A1 [DS938Z-FRA]
China
CCC
DS938Z: 2002031901000002
CCC
DS938Z-CHI: 2004031901000036
Sweden
INTYG
DS938Z only: 04-683
Installation/configuration notes
0 m
9 m
9 m
0 ft
30 ft
30 ft
Top View
360° x 18 m (60 ft) diameter
30 ft
0 ft
10 ft
9 m
0 m
3 m
30 ft
9 m
0 ft
0 m
AR8-13 Side View
360° x 18 m (60 ft) diameter
0 ft
30 ft
30 ft
0 ft
10 ft
15 ft
0 m
9 m
9 m
0 m
3 m
4.5 m
AR13-18 Side View
360° x 18 m (60 ft) diameter
Technical specifications
Enclosure Design
Material:
High impact ABS plastic enclosure
Dimensions:
8.4 cm x 13.3 cm
(3.3 in. x 5.25 in.)
Environmental Considerations
Operating Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Listed Applications,
0°C to + 49°C (+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies
in the range from 26 MHz to 950 MHz at
50 V/m.
DS938Z:
Complies with Environmental Class II
(EN50130-5)
Mounting
Height (recommended):
2.5 m to 6 m (8 ft to 18 ft)
Location:
Mounts directly to ceiling or to standard
octagonal electrical box.
Internal Pointability:
Coverage is adjustable ±10° horizontally,
+2° to -18° vertically.
Outputs (DS models)
Alarm:
Form C reed relay at 3.0 W, 125 mA at 28 VDC for
resistive loads
Tamper:
Normally-closed. Contacts rated at 28 VDC, 125 mA
maximum.
Outputs (ZX model)
Alarm:
Signal through POPEX data bus.
Tamper:
Signal through POPEX data bus. Signaled as missing.
Trouble:
Signal through POPEX data bus.
Power Requirements (DS models)
Current:
18 mA at 12 VDC
Voltage:
6 VDC to 15 VDC
2 | DS938Z and ZX938Z Series Panoramic PIR Detectors