background image

DS835 Series Installation Instructions                     © 2011 Bosch Security Systems, Inc.

Page 3

• Walk test 

across

 the pattern at its farthest edge, then several times

closer to the detector. Start walking from outside of the intended
protection area, and observe the tricolor LED. The edge of the pattern
is determined by the first green, PIR activation of the LED (or the
first red activation if the yellow microwave LED activates first).

• Walk test from the opposite direction to determine both boundaries.

The center of the pattern should be pointed toward the center of the
intended protection area.

NOTE

:

The pattern may be moved ±10° horizontally by rotating the
lens window left or right.

• Slowly bring your arm up and into the pattern to mark the lower boundary

on PIR alarm. Perform this task at 10 to 20 ft. (3 to 6 m) from the unit.
Repeat from above for the upper boundary. 

The center of the pattern

should not be tilted upward

.

 

NOTE:

If the desired coverage cannot be achieved, try angling the
coverage pattern up or down to assure the pattern is not aimed
too high or low. The angle of the PIR pattern may be vertically
positioned between -10° and +2° by loosening the Vertical Adjust
screw and sliding the circuit board up or down. Moving the board
up will angle the pattern downward.

• Tighten the Vertical Adjust screw when positioning is completed.

7.2

Establishing Microwave Coverage

NOTE

: It is important to wait one minute after removing/replacing the

cover so the microwave portion of the detector can settle, and
to wait at least ten seconds between the following walk testing
procedures.

• The tricolor LED should be OFF before walk testing.

• Walk test 

across

 the pattern at the intended coverage’s 

farthest

 end.

Start walking from outside the intended protection area and observe
the tricolor LED. The edge of the microwave pattern is determined by
the first yellow, microwave activation of the LED (or the first red
activation if the green PIR LED activates first).

• If adequate range can not be reached, increase the Microwave Range

Adjust 

slightly

. Continue walk testing (waiting one minute after

removing/replacing the cover) and adjusting the range until the farthest
edge of desired coverage has been accurately placed.

NOTE:

Do 

not

 adjust the microwave range higher than required. Doing

so will enable the detector to catch movement outside of the
intended coverage pattern.

• Walk test the unit from all directions to determine all the Microwave

pattern boundaries.  Wait at least ten seconds between walk tests.

7.3

Establishing Detector Coverage

• The tricolor LED should be OFF before walk testing.

• Walk test the unit from all directions to determine the detection

boundaries. A detector alarm is signaled by the first red activation
of the tricolor LED after an initial green or yellow activation.

8.0

Supervision Features

The supervision features function as follows:

PIR/Microwave:

  The complete circuit operation of these

subsystems is checked approximately every 12 hours.  If the PIR or
MW subsystem fails, the tricolor LED will flash red four times per
cycle and the unit should be replaced.

Default

:  If the microwave subsystem fails, the detector will default

to PIR technology protection. The PIR signal sensitivity will
automatically change from INT to STD.

9.0

Maintenance

At least once a year, the range and coverage should be verified. To
ensure continual daily operation, the end user should be instructed
to walk through the far end of the coverage pattern. This ensures an
alarm output prior to arming the system.

10.0 Coverage Patterns

The protected coverage area is where the microwave and PIR patterns
overlap.

An optional Look Down lens is located under the detector. 

This lens

must be unmasked before it is operational.  Use caution to remove
the black mask only. Do not attempt to remove the white lens
assembly.

 The Look Down lens is 

not recommended

 for installations

containing pets or small animals.  The Look Down zone is shown in
black on the Coverage Pattern drawings.

0

0

M

L

K

Q

U

Y

J

Z

X

T

P

A

B

C

N

R

V

W

S

O

D

E

F

G

H

I

0

5

5

0

5

10

15

20

10

15

20

Feet

25

30

35

10

15

20

1.6

Meters

3.2

4.8

6.4

8

9.6

11.2

5.6

4.2

2.8

1.4

1.4

2.8

4.2

5.6

TOP VIEW

0

0

2

-5°

A-M

N-Q

R-U

V-Y

Z

0

0

5

Remove masking for Look Down Zone.

3

1.6

3.2

4.8

Meters

SIDE VIEW

6.4

8

9.6

11.2

10

Feet

10

15

20

25

30

35

Содержание DS835

Страница 1: ...nc Web site at http www boschsecurity com datecodes 2 0 Installation Considerations Never install the detector in an environment that causes an alarm condition in one technology Good installations start with the LED OFF when there is no target motion It should never be left to operate with the tricolor LED in a constant or intermittent green yellow or red condition Point the unit away from outside...

Страница 2: ... is not desired after setup and walk tests are completed place in the OFF position The OFF position does not prevent the LED from indicating supervision trouble conditions On Off 6 2 PIR Sensitivity Selection Pins For selection place the plug across the pins marked STD for Standard or INT for Intermediate mode INT STD Standard Sensitivity The recommended setting for maximum false alarm immunity To...

Страница 3: ...esting waiting one minute after removing replacing the cover and adjusting the range until the farthest edge of desired coverage has been accurately placed NOTE Do not adjust the microwave range higher than required Doing so will enable the detector to catch movement outside of the intended coverage pattern Walk test the unit from all directions to determine all the Microwave pattern boundaries Wa...

Страница 4: ...used by the following sources One dog up to 100 Lbs 45 kg Two dogs up to 60 Lbs each 27 kg each Up to 10 cats Multiple small rodents such as rats Random flying birds To take full advantage of the DS835 s Signature Recognition Technology the following guidelines should be followed Mount the detector 6 5 ft 2 m high and adjust the PIR angle to 5 6 5 ft 2 m Set the PIR sensitivity for Standard STD IN...

Отзывы: