Installation Instructions

for the DS835 Series

TriTech Microwave/PIR Intrusion Detectors

1.0

Specifications

•  

Dimensions

   (HxWxD):

5 in. x 2.8 in. x 2.2 in.
(12.7 cm x 7.1 cm x 5.6 cm)

•  

Input Power:

9 to 15 VDC, 16 mA DC nominal (up to 48 mA
DC during walk testing or trouble conditions).
Use only an  Approved Limited Power
Source.

•  

Standby Power:

No internal standby battery. Standby power

must

 be provided by an  Approved Limited

Power Source. Sixteen mAh required for
each hour of  standby time needed.

•  

Alarm Relay:

Silent-operating Normally Closed  reed relay.
Contacts rated 3 watts, 125 mA, 28 VDC
maximum for DC resistive loads; and
protected by a 4.7 ohm, ½ watt resistor in the
common "C" leg of the relay. To be connected
to a SELV (Safety Extra-Low Voltage) circuit
only. Do 

not

 use with capacitive or inductive

loads.

•  

Tamper:

Normally Closed (with cover on). Contacts
rated at 28 VDC, 125 mA  max. To be
connected to a SELV (Safety Extra-Low
Voltage) circuit only. Connect tamper circuit
to a 24-hour protection circuit.

•  

Temperature Range:

-40°F to +120°F (-40°C to +49°C). For UL
Listed requirements, the  temperature range
is +32°F to +120°F (0°C to +49°C), indoor
use.

•  

Microwave Frequency:

   

DS835:

10.525 GHz (UL Listed)

   

DS835A:

10.687 GHz (Export only, not UL Listed)

   

DS835B:

9.9 GHz (Export only, not UL Listed)

•  

Coverage:

35 ft. by 35 ft. (10.7 m by 10.7 m)

•  

Internal Pointability:

+2° to –10° Vertical, ±10° Horizontal.

•  

Options:

B328 Gimbal Mount Bracket, B335 Low
Profile Swivel Mount Bracket, B338 Ceiling
Mount Bracket

NOTE:

Use of a bracket may reduce range and dead zone areas;
not recommended for installations containing pets.

•  

Compliance:

This device complies with Part 15 of the FCC
Rules and with RSS-210 of Industry and
Science Canada. Operation is subject to the
following two conditions:

(1)

This device may not cause harmful interference, and

(2)

This device must accept any interference received, including
interference that may cause undesirable operation.

Changes or modifications not expressly approved by Bosch Security
Systems can void the user’s authority to operate the equipment.

•  

Reading Bosch Security Systems, Inc. Product Date Codes

For Product Date Code information, refer to the Bosch Security Systems,
Inc. Web site at: 

http://www.boschsecurity.com/datecodes/

2.0

Installation Considerations

•  

Never

 install the detector in an environment that causes an alarm

condition in one technology. Good installations start with the LED

OFF

 when there is no target motion. It should never be left to operate

with the tricolor LED in a constant or intermittent green, yellow, or
red condition.

• Point the unit away from outside traffic (roads/alleys).

NOTE:

Microwave energy will pass through glass and most
common nonmetallic construction walls.

• Avoid installations where rotating machines (e.g. ceiling fans) are

normally in operation within the coverage pattern. Point the unit away
from glass exposed to the outdoors and objects that may change
temperature rapidly.

NOTE:

The PIR detector will react to objects rapidly changing
temperature within its field-of-view.

• Eliminate interference from nearby outside sources.

3.0

Mounting

• Select a location likely to intercept an intruder moving 

across

 the

coverage pattern. The surface should be solid and vibration-free.
Mounting height range is 6 to 8 ft. (1.8 to 2.4 m). Recommended
mounting height is 6.5 ft. (2 m).

• Remove the cover. Insert a flathead screwdriver into the locking tab

hole at the bottom front of the detector. Pull the cover up and forward.

Vertical

Adjust

Screw

Tri-color

LED

Terminal

Strip

LED

On/Off

Pins

MW

- 4°
- 8°

On

Off

Microwave

Range Adjust

PIR

Sensitivity

Selection Pins

Vertical Adjust

 Scale

Look Down Lens

MIN

MAX

Face of Lens

 (masking area)

Corner Mount

Knockout (4)

Surface Mount

Knockout (2)

Wire
Entrances

Bracket Mount

Knockout

Vertical Adjust
Screw Mount

Cover Tab and

Locking Screw Hole

Wire
Entrances

• Remove the circuit board from the base. Loosen the Vertical Adjust

Screw and slide the circuit board down, then out.

• Break away the appropriate thin-wall wire entrance and mounting hole

coverings in the base.

• Using the base as a template and aligning it so that the detector will be

mounted with the terminal block at the top and the PIR lens at the
bottom, mark the location of the mounting holes on the mounting
surface. Pre-start the mounting screws.

• Route wiring as necessary. Route to the rear of the base and through

the wire entrance. 

Make sure all wiring is unpowered before routing.

• Securely attach the base to the mounting surface.

• Return the circuit board to the base and tighten the Vertical Adjust

Screw.

Содержание DS835

Страница 1: ...nc Web site at http www boschsecurity com datecodes 2 0 Installation Considerations Never install the detector in an environment that causes an alarm condition in one technology Good installations start with the LED OFF when there is no target motion It should never be left to operate with the tricolor LED in a constant or intermittent green yellow or red condition Point the unit away from outside...

Страница 2: ... is not desired after setup and walk tests are completed place in the OFF position The OFF position does not prevent the LED from indicating supervision trouble conditions On Off 6 2 PIR Sensitivity Selection Pins For selection place the plug across the pins marked STD for Standard or INT for Intermediate mode INT STD Standard Sensitivity The recommended setting for maximum false alarm immunity To...

Страница 3: ...esting waiting one minute after removing replacing the cover and adjusting the range until the farthest edge of desired coverage has been accurately placed NOTE Do not adjust the microwave range higher than required Doing so will enable the detector to catch movement outside of the intended coverage pattern Walk test the unit from all directions to determine all the Microwave pattern boundaries Wa...

Страница 4: ...used by the following sources One dog up to 100 Lbs 45 kg Two dogs up to 60 Lbs each 27 kg each Up to 10 cats Multiple small rodents such as rats Random flying birds To take full advantage of the DS835 s Signature Recognition Technology the following guidelines should be followed Mount the detector 6 5 ft 2 m high and adjust the PIR angle to 5 6 5 ft 2 m Set the PIR sensitivity for Standard STD IN...

Отзывы: