DS7200V2-UK Installer's Guide 

PART IV: CONTROL PANEL PROGRAMMING 

44.0  Global Output Configuration 

The DS7240V2 supports Outputs 1-20: four on-board Programmable Outputs (PO 1 to PO 4), and up to 16 off-board. The 
DS7220V2 supports Outputs 1-12: four on-board Programmable Outputs (PO 1 to PO 4), and up to 8 off-board. 

Outputs 5 through 12 are available on an off-board Data Bus device (DX3010 Octo-Output Expander or DX3020 X-10 Control 
Module) at Data Bus Address 150. 

Outputs 13 through 20 (DS7240V2 only) are available on an off-board Data Bus device (DX3010 Octo-Output Expander) at 
Data Bus Address 151. 

Global Output Options 

 Address: 1039 

 Default: 5 

 Selections: 0-15 

 

Enter This Data Digit to Select Options 

Global Output Options 

9  10  11  12  13  14  15 

No Options Selected 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output 2 is Supervised Horn/Strobe Speaker Output  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Send Output Set/Reset Reports 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable Strobe Arming Flash to indicate RF Keyfob & 
Keyswitch Arm/Disarm 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable Alarm Output Arming Beep to indicate RF Keyfob & 
Keyswitch Arm/Disarm 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

This parameter affects all programmable outputs. 

 Output 2 Is Supervised Horn/Speaker Output: This option turns Programmable Output 2 (PO 2) into a supervised siren 

driver. If a siren or speaker is not connected, the control panel generates a Siren Trouble event that can include a Siren 
Trouble {193} report. The restoral event is reported with Siren Trouble Restore {194}. See On-board Output Setup on page 
16 for more information. Compatible speakers include D118 and D119 Speaker Drivers.  

 Send Output Set/Reset Reports: This option allows the control panel to send Output Set {109 to 111} and Output Reset 

{106 to 108} reports when outputs are operated by a user, a Sked or RPS (Remote Programming Software). 

 Enable Strobe Arming Flash to Indicate RF Keyfob and Keyswitch Arm/Disarm: This option allows the Strobe Output 

Function (1|6) to indicate RF and keyswitch arming and disarming as follows: 

  3 seconds = transition to Off (disarmed) 

  6 seconds = transition to All On or Perimeter Only 

 Enable Alarm Output Arming Beep to Indicate RF Keyfob and Keyswitch Arm/Disarm: This option allows any Alarm 

Output Functions (1|8, 1|9, 1|10, and 8|8) to indicate RF and Keyswitch arming and disarming as follows: 

  1 Beep = transition to Off (disarmed) 

  2 Beeps = transition to All On 

  3 Beeps = transition to Perimeter Only 

 

The “Enable Alarm Output Arming Beep to Indicate RF Keyfob and Keyswitch Arm/Disarm” option is 
only available for RF Keyfobs (not RF Keypads) and when arming from RPS or a keyswitch. 

Содержание DS7200V2-UK

Страница 1: ...umper must be closed Orange Yellow Green Yellow Blue Brown Rated Voltage 230 V Rated Frequency 50 Hz Rated Input Current 250 mA max For PERMANENTLY CONNECTED EQUIPMENT a readily accessible disconnect device shall be incorporated into the building installation wiring CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS Maximum...

Страница 2: ...Speaker alarm function PTC suppressed 13 Alrm Alarm power Up to 1 850 mA PTC suppressed Provides power for supervised siren driver PO 2 and Alarm Output PO 1 A 14 PO 1 A 15 PO 1 B Jumper sets PO 1 terminals A 14 and B 15 for dry Form A contact or for Alarm Output using PO 1 A as negative terminal 16 SMK Not used 17 L 1 Sensor Loop 1 Wire length for Sensor Loops 1 to 8 are limited only by the resis...

Страница 3: ...X2010 DX3010 RF3227E Conforms with the requirements of European Council Directive 89 336 EEC and the following requirements Requirements EN 55022 1998 EN 50130 4 1995 EN 60950 2000 EN 61000 3 2 EN 61000 3 3 EN 61000 4 2 Electrostatic Discharge Immunity EN 61000 4 3 Radiated Electromagnetic Field Immunity EN 61000 4 4 EFT Burst Immunity EN 61000 4 5 EMC Surge Immunity EN 61000 4 6 EMC Conducted Imm...

Страница 4: ...Receiver Setup 18 17 1 RF Receiver Addressing 18 17 2 RF3227E Installation 18 17 3 RF3227E Programming 18 17 4 RF Receiver Supervision 18 18 0 Off board Sensor Loops DX2010 18 18 1 DX2010 DX2013 DX2014 Overview 18 18 2 DX2010 Installation 18 18 3 DX2010 Wiring 19 18 4 DX2010 Auxiliary Output Connections 20 18 5 DX2010 Tamper Input Connections 21 18 6 DX2010 Tamper wired Configuration 21 18 7 DX201...

Страница 5: ... 16 Figure 11 Single Zone Sensor Loop Wiring No EOL 16 Figure 12 4 wire Smoke Detector Tamper wired 16 Figure 13 PO 1 Wiring 17 Figure 14 PO 2 PO 4 Wiring 17 Figure 15 RF3227E Address Jumper Settings 18 Figure 16 RF3227E to Control Panel Wiring 18 Figure 17 DX2013 Mounting Locations 18 Figure 18 Mounting the DX2013 Step 1 19 Figure 19 Mounting the DX2013 Step 2 19 Figure 20 Mounting the DX2013 Ste...

Страница 6: ... Number Addresses Defaults 60 Table 24 Account Number Entry Selections 60 Table 25 Key Character Assignments 62 Table 26 User Configuration 64 Table 27 Location Configuration Parameters 72 Table 28 Default Zone Function Type Selections 76 Table 29 Location Text Addresses Defaults 79 Table 30 Zone Function Configuration 80 Table 31 Output Configuration Parameters 86 Table 32 Output Function Types 8...

Страница 7: ...ed for successful operation The Caution Note identifies information intended to prevent an incident that may prohibit the functionality of the program equipment The Warning Note identifies information intended to prevent an incident that may prohibit the functionality of the program equipment and or personal injury 1 3 Other Conventions Programming parameter titles are identified as follows Progra...

Страница 8: ...o a single area or spread out over the available areas You arm and disarm the panel by area You can arm and disarm several areas with one function You can also assign a PIN an authority level that allows a user to arm an area from a remote keypad in another area Assigning each area its own account number creates separate accounts in one panel Assigning the same account number to different areas gr...

Страница 9: ...pad that displays up to 16 zones DS7445V2 LED Keypad LED keypad in new faceplate design DS7447E Text Keypad Text keypad that displays system information and programmable text DS7447V2 Text Keypad Text keypad in new faceplate design Door Access Control Module DACM The DACM grants or restricts access to a door using a keypad credential reader a Request to Exit REX input or a door contact Each DACM s...

Страница 10: ...oke detector with built in 135 F 57 C heat sensor and 85 dB sounder RF835E Wireless TriTech PRI Microwave Detector Wireless detector that utilizes passive infrared PIR technology microwave MW technology and artificial intelligence to detect motion RF940E Wireless PIR Detector High performance PIR motion sensor 6 4 Programming Tools DS7447E DS7447V2 Text Keypad Required for keypad programming PK32 ...

Страница 11: ...e any static charge you may be carrying before working on the control panel 10 1 Electro Magnetic Interference EMI EMI might occur if you install the system or run system wires near any of the following Computer network system Electrical lines fluorescent fixtures or telephone lines Amateur radio transmitter site Heavy machinery and motors High voltage electrical equipment or transformers PBX tele...

Страница 12: ...e control panel s Batt connector Then push the lead s other connector on the positive side of the battery See Figure 3 for details Control Panel Board BATT BATT Red Black Standby Battery Figure 3 Battery Connections High current arcs are possible The positive red battery lead and the panel s BATT connector can create high current arcs if shorted to terminals or enclosure Use caution when working w...

Страница 13: ... 4998153891 for details Bad line might test OK the telephone line test circuit uses the voltage level to test the status of the phone line In some instances a given telephone line might be out of service without affecting the voltage on the line The phone line monitor cannot recognize this trouble condition 13 0 Communication Failure Comm Fail The control panel routes reports to two routing destin...

Страница 14: ...on Consult your keypad s installation manual for complete instructions Keypads connect to the control panel in parallel as shown in Figure 7 You can use either one of the Aux Power terminals and either one of the 12 VDC terminals when connecting devices to the control panel Control Panel Keypad BATT BATT Data In Data Out 12 VDC Com Green Yellow Red Black Figure 7 Keypad to Control Panel Wiring See...

Страница 15: ...am the keyswitch see Options 1 for Zone Function Type 10 Controlled Keyswitch on page 78 2 2 k Ω Common Zone Input Figure 9 Keyswitch Wiring 14 2 4 Arming Disarming with a Keyswitch The control panel offers a wide variety of keyswitch arming options See Options 1 for Zone Function Type 10 Controlled Keyswitch on page 78 for keyswitch arming configuration options 14 2 5 Silencing Alarms with a Keys...

Страница 16: ...ally Open Contacts 100 ohms maximum Figure 11 Single Zone Sensor Loop Wiring No EOL 15 4 Four wire Smoke Detector Configuration A four wire smoke detector can be connected to any of the control panel s on board sensor loops L 1 to L 8 A four wire smoke detector requires the use of a relay module to interrupt power to the detector in order for the detector to reset The output controlling the relay ...

Страница 17: ...TT BATT ALRM PO1 L 1 SMK PO1 SELECT COM A B Figure 13 PO 1 Wiring 16 3 Programmable Outputs 2 4 PO 2 PO 4 PO 2 can be used with ALRM as a supervised siren driver Connect an approved 4 or 8 Ω siren Alternatively PO 2 can sink up to 500 mA 12 VDC See Figure 14 for details PO 3 and PO 4 can be configured for Alarm Output These outputs can sink up to 500 mA 12 VDC each See Figure 14 for details Defaul...

Страница 18: ...o the RF receiver If it fails to communicate with the RF receiver it sends a Dbus Missing 125 report 18 0 Off board Sensor Loops DX2010 18 1 DX2010 DX2013 DX2014 Overview The DS7240V2 supports up to 5 DX2010 Input Expanders The DS7220V2 supports up to 3 DX2010 Input Expanders Each DX2010 adds eight zones to the system See Locations on page 72 for information on how the DX2010 sensor loops are assi...

Страница 19: ...e Bracket Figure 19 Mounting the DX2013 Step 2 3 Secure the DX2013 to the CX1011 enclosure wall with a mounting screw provided with DX2013 See Figure 20 Enclosure Back Wall Mounting Screw Front of Angle Bracket Front of DX2013 Figure 20 Mounting the DX2013 Step 3 18 3 DX2010 Wiring Do not use twisted pair or shielded cable when wiring the DX2010 Refer to the following data bus wire length requirem...

Страница 20: ...e black output to earth ground when using any external power supply A ground fault condition is reported if black is grounded 18 4 DX2010 Auxiliary Output Connections The DX2010 can provide 12 VDC at up to 100 mA from the Auxiliary Output OUT terminals to power external devices such as motion detectors See Figure 23 TMPR 1 COM R B G Y Motion Detectors Photobeams etc DX2010 OUT Red Black Figure 23 ...

Страница 21: ...put or the on board tamper switch Both cannot be used simultaneously 1 R B G Y DX2010 OUT TMPR COM On board tamper switch Figure 24 DX2010 Tamper Input Wiring 1 R B G Y DX2010 OUT TMPR COM On board tamper switch Figure 25 DX2010 Wire Jumper Connections 18 6 DX2010 Tamper wired Configuration For tamper wired sensor loop configuration wire as shown in Figure 26 3 4 5 6 7 8 COM COM COM Tamper Contact...

Страница 22: ...ut Expander allows you to add outputs to your system in groups of eight The DS7240V2 supports up to 20 programmable outputs 4 on board 16 off board via 2 DX3010 Output Expanders The DS7220V2 supports up to 12 programmable utputs 4 on board 8 off board via 1 DX3010 Output Expander You can assign any of the programmable output functions to the DX3010 s individual outputs separately See Outputs on pa...

Страница 23: ...locations DX3013 Mounting Locations DX3013 Mounting Locations INSTALLER PO4 PO3 PO2 Figure 29 DX3013 Mounting Locations Use the following steps to install a DX3013 in the CX1011 Enclosure 1 Insert the DX3013 s angle bracket hooks into the mounting slots in the back wall of the CX1011 Enclosure See Figure 30 Hook Slot Screw Hole Enclosure Back Wall Back of DX3013 Mounting Plate Back of Angle Bracke...

Страница 24: ...e 34 for external power supply connections Power Source 22 AWG 0 8 mm 18 AWG 1 2 mm Control Panel to DX3010 Control Panel 12 2 m 24 4 m Control Panel to DX3010 305 m 610 m External Power Supply to DX3010 External Power Supply 12 2 m 24 4 m Table 9 DX3010 Wire Lengths You can use either one of the Aux Power terminals and either one of the 12 VDC terminals when connecting devices to the control pane...

Страница 25: ... If it fails to communicate with the DX3010 it sends a Dbus Missing 125 report 20 0 RS 232 Serial Interface DX4010i DX4010 There are some PCB layout differences between the DX4010i and the DX4010 However the two modules wire program and operate the same The figures in this section show the DX4010i s PCB 20 1 DX4010i DX4010 Overview Both modules are RS 232 serial interface modules that connect a st...

Страница 26: ...S by using a direct connection between the module and the control panel The control panel s Installer Switch must be closed in order to perform a remote programming direct connection Follow these steps to connect directly to the control panel for an RPS session 1 Make sure the address DIP switches are set to Address 0 zero See Figure 38 for correct DIP switch placement The DX4010 does not use DIP ...

Страница 27: ...er pins can clear the ground condition Some devices can cause a ground fault even if the P1 jumper plug is removed DB9 GND ENABLE P1 DB9 Ground Enable Pins P1 Disabled Enabled Figure 41 P1 Jumper Pin Settings 20 4 2 P2 LED Enable Use the diagnostic LEDs for troubleshooting purposes See Figure 42 to enable disable these LEDs SER Rx Tx BUS Rx Tx LED ENABLE P6 P2 LED Enable Pins P2 Diagnostic LEDs Di...

Страница 28: ...can also be used for remote programming sessions with RPS Remote Programming Software 21 2 DX4020 Addressing Set the DIP Switch address to 134 when using the DX4020 for network communication Network Communication DIP Switch Setting Example Module Address 134 Switch OPEN Up Switch CLOSED Down OPEN 1 2 3 4 5 6 7 8 DX4020 Mounting Locations Figure 45 Network Communication DIP Switch Setting 21 3 DX40...

Страница 29: ...234 s hooks into the mounting slots in the back wall of the CX1011 Enclosure See Figure 48 Hook Slot Screw Hole Enclosure Back Wall Back of DX4020 Back of B234 Angle Bracket Figure 48 Mounting the DX4020 Step 2 3 Pull the B234 down so that its hooks are flush in the mounting slots See Figure 49 Hooks flush with Slots Back of DX4020 Screw Hole Enclosure Back Wall Back of B234 Angle Bracket Figure 4...

Страница 30: ...rminals and either one of the 12 VDC terminals when connecting devices to the control panel BATT BATT DX4020 Control Panel Red Black Green Yellow Figure 51 DX4020 to Control Panel Wiring You can use either one of the Aux Power terminals when connecting devices to the control panel Do not tie the black output to earth ground when using any external power supply A ground fault condition is reported ...

Страница 31: ...pports up to 8 DACMs However each DACM added to the system replaces one keypad If 8 DACMs are added you cannot add a keypad For full system control make sure at least one text keypad is included in the system See DACM Configuration on page 116 for programming instructions The DACM grants or restricts access to a door using a keypad credential reader a Request to Exit REX input and or a door contac...

Страница 32: ...trouble upon any power up because the date and time settings are missing This trouble remains until these settings are made To reduce the occurrence of false alarms upon control panel power up or restoration of power after a complete loss of primary and secondary power the control panel ignores all zone faults for approximately 60 seconds while the devices stabilize 24 0 System Status LED The Syst...

Страница 33: ...s and the 20 minute timer is started If 8 is pressed to enter keypad programming the control panel enters keypad programming even if keypad programming is disabled When the Installer Menu is exited the control panel reverts to normal operation 27 0 Installer Menu The Installer Menu consists of the following choices the numbers preceding the descriptions represent the keypad number key to press 1 B...

Страница 34: ...g a Location 27 7 1 Adding RF ID Codes Before an RF ID can be added corresponding locations must first be programmed as RF devices 1 Press 1 from the RF Menu to add RF ID codes into the system The display then scrolls all locations requiring RF Ids Loc9 A1 Zn9 To add push 9 2 To add an RF ID to the system as shown in the display above Location 9 used as an example press 9 followed by The following...

Страница 35: ...ered activations P08 Message packet transmission Alarm Panic and Restoral messages are transmitted with 8 packets Alarm and Restoral refer to the transitions in and out of alarm conditions Supervisory and Test transmissions smoke detectors consist of 4 packets RF keypads send 4 packets for all keys except the Emergency keys which transmit 8 packets RF key fobs send 4 packets for normal operation a...

Страница 36: ...ram key is OK to use Press to stop the check Erase Key Press 4 to erase the contents of the program key The program key connects to the pins marked AUXILLARY on the control panel board See Figure 58 AUXILIARY Programming Key PK32 Status LED Control Panel Auxiliary Pins Figure 58 PK32 to Control Panel Connections 27 7 6 Call for Service Press 0 from the Installer Menu to display system troubles req...

Страница 37: ...from an text keypad Press 9 1 Enter the Installer PIN if prompted Press each key on the keypad when prompted Each key press serves as a sounder test and display test Observe the keypad s LED s when prompted This prompt occurs following a 3 second delay after all keys are pressed and all LEDs turn on Press to end the test The keypad returns to the idle condition normal display Follow these steps to...

Страница 38: ...staller Keypad to the control panel if you are using an Installer Keypad d Restore all power to the control panel e Locate the keypad displaying the Installer Menu f Press the 8 key 28 2 Expert Installer Programming Modes Installer Programming Mode Installer Programming Mode is the control panel s default programming mode This mode allows the installer to access only a subset of the available prog...

Страница 39: ...esses These addresses are only available when the control panel enters Expert Programming Mode DS7240V2 DS7220V2 0214 219 0214 219 0237 0237 0282 0285 0282 0285 0292 0295 0292 0295 0304 0307 0304 0307 0314 0317 0314 0317 0326 0329 0320 0363 0336 0339 0826 0905 0348 0351 1035 1037 0358 0361 1252 1035 1037 1262 1252 1522 1649 1262 2418 2929 2940 2943 2940 2943 2945 3405 2945 3405 3430 3505 3541 3545...

Страница 40: ...k Moves to the address after the text block A Moves cursor to the previous character position in text block C Moves cursor to the next character position in text block Table 21 Key Character Assignments The following keys are not used in text programming and produce an error tone when pressed B Key On Off Perimeter Only No Entry Bypass System Reset Press the 1 key once to clear a character space o...

Страница 41: ...are not programmed by default 29 0 Understanding the Parameter Option Charts The programming section of this document uses charts like the one below to identify the available selections for option parameters Enter This Data Digit to Select Options Phone Line Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No Phone Line Options Do Not Wait for Dial Tone R Function Three way Calling Call Barring Phone...

Страница 42: ...stination 2 0066 0097 Phone Number 2 Destination 2 0098 0129 Default All zeroes 0 Selections 0 15 see Table 22 Digit Enter at the Keypad Digit Enter at the Keypad 1 1 9 9 2 2 0 10 3 3 11 4 4 12 5 5 P 4 second pause 13 6 6 F on hook pause off hook 14 7 7 Reserved 15 8 8 T Terminate 0 Table 22 Phone Number Entry Selections When entering phone numbers use 10 1 0 from the keypad to enter 0 use 0 to te...

Страница 43: ...ing to transmit reports in BSIA Fast Format If you configure the control panel for network communication you must set this parameter to Contact ID See Network Communication on page 112 for more information Firmware revision 2 10 or greater is required for network communication Check control panel communications from control panel to ARC to verify that the control panel is communicating properly in...

Страница 44: ... 261 is programmed into the control panel s Call Forwarding Auto Off Digits see Call Forwarding Auto On Off Digits Call Barring on page 45 for more information on the control panel s Call Forwarding Auto On Off Digits When this option is selected the control panel goes off hook and dials the number stored in the Call Forwarding Auto Off Digits every time the control panel is powered up or goes thr...

Страница 45: ...ff the Call Forwarding service See the DS7200V2 User s Guide P N 4998152530 for more information on Call Forwarding To use the Call Barring function enable it from the Phone Line Options parameter see page 44 and then enter the Call Barring number sequence into the Call Forwarding Auto Off digits typically 261 A typical dialing sequence might be two digit telephone company feature code 21 pause ph...

Страница 46: ...e Answering Machine Bypass function can be restricted to only operate when the system is armed All On or Perimeter Only see Arming Options 1 on page 54 When the Answering Machine Bypass function is restricted to only operate when the system is armed Normal or Perimeter Only the control panel does not answer the phone for a remote arming session when it is disarmed Off However 4 3 still begins a re...

Страница 47: ...l Service Delay Alarm Output The control panel delays burglary alarm output until communication to the ARC receiver is complete or there are two failed dialing attempts The delayed alarm output functions are 1 8 1 9 1 10 and 8 8 see Table 32 for descriptions of output types Bell Time is not delayed and begins at the alarm event If Bell Time is set at three minutes or less alarm output delayed by t...

Страница 48: ...equence and Communication Failure Comm Fail on page 13 for a description of the Comm Fail event Call for Service Interval Address 0227 0228 Default 0 0 Selections 00 99 Use this parameter to determine the interval in weeks 7 days 00 to 99 For example if you enter 0 2 the control panel waits 2 weeks 14 days between displaying service messages At this interval the keypad displays a Call for Service ...

Страница 49: ...nterval At the System Inactive Interval the keypad displays a Call for Service trouble at all keypads and or sends a System Inactive 136 report for that area See System Inactive Interval on page 48 Enable Weekly Test Reminder If you select this option the system keypads display System Test Due Press 1 to test A reminder is generated eight 8 days after the last user test There is no trouble tone fo...

Страница 50: ...disables supervision No log threshold or overflow events are entered in the log No log reports are sent Setting this parameter to 1 2 or 3 creates log overflow and threshold events in the log A threshold event is created when the control panel writes the first event to the log that exceeds the threshold 50 75 or 90 full A threshold report reminds the ARC to access the event log with RPS freeing lo...

Страница 51: ...ort if Other Report Sent in Test Interval If another report is sent during the test interval this option defers the test report until the end of the test interval Test Reports for All Areas else Area 1 only If selected this option generates a test report for all enabled areas For the DS7240V2 this option applies to Areas 1 through 4 For the DS7220V2 this option applies to Areas 1 and 2 Call RPS at...

Страница 52: ...ne day and left programming mode at 10 10 am then the control panel does not send a test report until 10 20 the next day after the one day interval increment at midnight If the Automatic Test report is disabled in the Automatic Test Report Options parameter see page 51 this parameter is meaningless Test Report Routing Address 0255 Default 1 Reports to Destination 1 Events to Log Printer Selections...

Страница 53: ...ontrol panel parameters during the programming session it sends a Parameters Changed 98 report If the programming session is terminated with a reset panel from RPS the control panel sends a Reboot 104 report If the programming session is not successfully completed the control panel sends an Invalid Remote Access 102 report Select the Enable Remote Programming option to ensure that the following op...

Страница 54: ...o restrict its function so that it only operates when the system is All On or Perimeter Only On The system does not answer if disarmed Remote Arming with Telephone Area 1 If enabled this option controls the built in telephone arming feature for Area 1 When enabled the control panel answers the phone on the ring count for remote programming The following occurs when the control panel answers the ph...

Страница 55: ...ides the First Area to Open Last Area to Close Reporting option See Area Opening 89 96 Closing 42 67 Reporting Options on page 61 for more information on the Restrict Open Close Reports option All area account numbers must be the same in order to send Area 1 s account numbers See Areas on page 60 for account number programming instructions Make Area 1 Common Area If this option is enabled all othe...

Страница 56: ... these events occur in this order 1 Local alarm annunciation is started keypads and alarm outputs 2 Entry Delay starts 3 The alarm report process begins if the system is not turned off at the end of Entry Delay An Exit Error 18 report is included if programmed The Exit Error report follows the Alarm Report routing Recent Closing If this option is enabled an Alarm Recent Closing 19 to 20 report inc...

Страница 57: ...at the Entry Delay Time 1 parameter Zone function types programmed to initiate Entry Delay 2 use the entry delay time you set at the Entry Delay Time 2 parameter If the system is on and a user enters through a zone assigned to Entry Delay 2 the system initiates Entry Delay 2 If the user enters through a zone assigned to Entry Delay 1 and then through a zone assigned to Entry Delay 2 the system doe...

Страница 58: ... Delay Time 1 2 Address Exit Delay Time 1 0270 0271 Exit Delay Time 2 0272 0273 Default Exit Delay Time 1 1 14 30 seconds Exit Delay Time 2 3 12 60 seconds Selections 0 0 to 15 14 0 to 254 seconds Exit Delay is the time the system allows users to exit the premises Users must leave the premises before Exit Delay expires The control panel provides two Exit Delays When a user turns the system All On ...

Страница 59: ...isarmed unset with a portable ACE If the area is not disarmed with a portable ACE opening the initial Entry door disables all means of confirmation This parameter only controls confirmed alarm generation The ability to disarm unset with a keypad or RF keyfob is not controlled by this parameter Confirmed Alarm Reset Options Address 0275 Default 0 Selections 0 15 Enter This Data Digit to Select Opti...

Страница 60: ...13 5 5 E 14 6 6 F 15 7 7 Terminate 0 Table 24 Account Number Entry Selections Each area uses the account number entered here to report to the ARC receiver Different account numbers can be programmed for two routing destinations See Routing Destinations on page 42 for a complete description of how the control panel directs reports to the routing destinations Account numbers can contain up to six 6 ...

Страница 61: ... level Reporting must also be enabled at the system level see Global Reporting Options on page 47 Restrict Open Close Reports Open From Alarm Close on Force Arm If this option is enabled the control panel only sends opening reports when the user disarms the system after an alarm and when Bell Time has expired The control panel only sends closing reports when a zone is force armed Force arming is s...

Страница 62: ...Ä Ã å ä á à â ã α β Ç ç 3 D E F d e f 3 É Æ ë é è ê æ Φ δ ε 4 G H I g h I 4 ï í î ì Γ γ η ι 5 J K L j k l 5 Λ κ λ 6 M N O m n o 6 Ö ö Ñ ñ Ø Õ ø ó ò ô õ Ω µ ν ω 7 P Q R S p q r s 7 Π Σ π ρ σ 8 T U V t u v 8 Ü ü ú ù û Θ Υ θ τ υ 9 W X Y Z w x y z 9 ÿ Ξ Ψ ξ χ ψ ζ Moves to the address before the text block Moves to the address after the text block A Moves cursor to the previous character position in te...

Страница 63: ...e when the keypad is idle even if a zone is faulted If Don t Show Zone Status on Keypads is selected the default Area Idle Text Not Ready should be changed See Text Entry Addresses on page 40 for text entry instructions 37 0 PIN Configuration Installer PIN PIN Length Address 0379 Default 4 4 digits long Selections 3 7 3 digits min 7 digits max This parameter determines the number of digits in a PI...

Страница 64: ...Addr 0494 Addr 0495 Addr 0496 Addr 0497 13 Addr 0498 Addr 0499 Addr 0500 Addr 0501 Addr 0502 Addr 0503 Addr 0504 Addr 0505 Addr 0506 14 Addr 0507 Addr 0508 Addr 0509 Addr 0510 Addr 0511 Addr 0512 Addr 0513 Addr 0514 Addr 0515 15 Addr 0516 Addr 0517 Addr 0518 Addr 0519 Addr 0520 Addr 0521 Addr 0522 Addr 0523 Addr 0524 16 Addr 0525 Addr 0526 Addr 0527 Addr 0528 Addr 0529 Addr 0530 Addr 0531 Addr 053...

Страница 65: ...er The authority level assigns functions to the user s PIN and RF keyfob See RF Keyfobs on page 102 for a description of RF keyfobs and how to assign them to users Authority levels are configured as shown below See Authority Level Configuration in the DS7200V2 Expert Programming Guide P N 4998153891 to change the configuration of authority levels Authority Level 1 Master All options except for Opt...

Страница 66: ...eas 1 and 2 User 2 1 Assigned to Area 1 User 3 1 Assigned to Area 1 Users 4 32 0 Not assigned to an area Selections 0 15 Enter This Data Digit to Select Options User Area Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Not Assigned to an Area Assigned to Area 1 Assigned to Area 2 Assigned to Area 3 DS7240V2 only Assigned to Area 4 DS7240V2 only Assigning PINs to multiple areas allows users to view a...

Страница 67: ... Data Digit to Select Options Keypad DACM Area Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Keypad DACM not assigned disabled Assign Keypad DACM to Area 1 Assign Keypad DACM to Area 2 Assign Keypad DACM to Area 3 DS7240V2 only Assign Keypad DACM to Area 4 DS7240V2 only Device is a Keypad Device is a DACM Assign only one area to each keypad Users PINs can be assigned to multiple areas The Move to ...

Страница 68: ...econd at least the following keypad combinations 1 3 keys 4 6 keys 7 9 keys Area Options for Help Function Keys Address 1 3 Keys 0694 4 6 Keys 0696 7 9 Keys 0698 Default DS7240V2 15 DS7220V2 3 Selections 0 15 Enter This Data Digit to Select Options Keypad Help Function Keys Area Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Disabled for all Areas Keys work for Area 1 Keys work for Area 2 Keys work...

Страница 69: ... Alarm output is activated Emergency Alarm Response If enabled this option displays Alarm Key at the text keypads If programmed an Emergency Alarm 4 report is sent and the Burglary Alarm output is activated The following letters are assigned to the Help Function keys and appear in the alarm response message that is displayed by the text keypad 1 3 A 4 6 B 7 9 C For example if Fire Alarm Response i...

Страница 70: ...eter creates up to 4 Duress users and PINs Creating a Duress user does not change any other function programmed for that user Whenever a user enters a Duress PIN PIN assigned to a Duress user the control panel sends a Duress 74 report and executes functions per the Duress user s authority level DS7240V2 Procedure To create a unique Duress user and PIN for each area select Option 15 and then assign...

Страница 71: ...ard Code The Guard Code only works in the areas to which User 28 is assigned The authority level assigned to the Guard Code User 28 dictates which keypad functions the guard can use For example Authority Level Configuration Option 1 configures All On arming If this is set to 0 zero the guard can arm at any time If the guard s authority level does not allow All On arming then the guard can never ar...

Страница 72: ...0741 1 0742 4 0743 1 0744 0745 0 8 On board Loop 8 DBus Adr 101 Loop 8 DBus Adr 50 Xmitter 8 DBus Adr 51 Xmitter 8 DACM 9 0746 0 0747 14 0748 1 0749 0750 0 9 DBus Adr 102 Loop 1 DBus Adr 106 Loop 1 3 65 kΩ DBus Adr 50 Xmitter 9 DBus Adr 51 Xmitter 9 DACM 10 0751 0 0752 14 0753 1 0754 0755 1 0 DBus Adr 102 Loop 2 DBus Adr 106 Loop 2 3 65 kΩ DBus Adr 50 Xmitter 10 DBus Adr 51 Xmitter 10 DACM 11 0756...

Страница 73: ...8 DACM 29 0846 0 0847 14 0848 1 0849 0850 2 9 DBus Adr 104 Loop 5 DBus Adr 107 Loop 5 3 65 kΩ DBus Adr 50 Xmitter 29 DBus Adr 51 Xmitter 29 DACM 30 0851 0 0852 14 0853 1 0854 0855 3 0 DBus Adr 104 Loop 6 DBus Adr 107 Loop 6 3 65 kΩ DBus Adr 50 Xmitter 30 DBus Adr 51 Xmitter 30 DACM 31 0856 0 0857 14 0858 1 0859 0860 3 1 DBus Adr 104 Loop 7 DBus Adr 107 Loop 7 3 65 kΩ DBus Adr 50 Xmitter 31 DBus Ad...

Страница 74: ...10 zone doubled b Set the DX2010 s DIP switches to Address 107 Locations 25 to 40 See Table 8 on page 22 c Use 3 65 k EOL resistors on Locations 25 32 and 2 2 k EOL resistors on Locations 33 40 Locations 17 24 cannot be used for zone doubling when doubling on board and off board zones at the same time These locations can still be used as RF zones or as non doubled zones Location Device Address See...

Страница 75: ...r is mounted on a doorjamb and its magnet on the door Closing the door places the magnet next to the reed switch Now the control panel has seen the reed switch in a normal not faulted state From this point forward it will show the zone door window transmitter as shorted faulted whenever it sees the reed switch faulted It will show the zone as normal when the reed switch returns to normal even thou...

Страница 76: ... Controlled zones are turned on and off when the user turns the system on armed and off disarmed See Table 28 for Zone Function type selections Selection Default Zone Function Type 0 Disabled 1 24 hour Fire 2 24 hour Fire with Alarm Verification 3 24 hour Control Input 4 24 hour Tamper 5 24 hour Emergency 6 24 hour Visible Panic 7 24 hour Invisible Panic 24 hour Zones 8 24 hour Burglary 9 Controll...

Страница 77: ...is option also allows an external module to signal that it is unable to send reports When this option goes into alarm the control panel initiates a System Trouble condition Event 167 is placed in the history log and its report is sent if there is means of sending the report When this input restores from alarm Event 168 is placed in the history log and its report is sent The System Trouble conditio...

Страница 78: ...eter Only Off from Any 13 Momentary Perimeter Only No Off 14 Momentary No On Off from Perimeter Only or Partial On Arming 15 Exit Terminator Button Momentary Keyswitch To silence alarms stop Alarm output operate the keyswitch If the area is armed operating the keyswitch to silence the alarm also disarms the area If the area is disarmed operating a momentary keyswitch to silence the alarm does not ...

Страница 79: ...746 Location 4 Text 24 2386 Location 24 Text 5 1778 Location 5 Text 25 2418 Location 25 Text 6 1810 Location 6 Text 26 2450 Location 26 Text 7 1842 Location 7 Text 27 2482 Location 27 Text 8 1874 Location 8 Text 28 2514 Location 28 Text 9 1906 Location 9 Text 29 2546 Location 29 Text 10 1938 Location 10 Text 30 2578 Location 30 Text 11 1970 Location 11 Text 31 2610 Location 31 Text 12 2002 Locatio...

Страница 80: ...Emergency Adr 0939 0 Adr 0940 0 Adr 0941 1 Adr 0942 3 Adr 0943 9 Adr 0944 1 Adr 0945 1 6 Adr 0946 6 24 hr Visible Panic Adr 0947 0 Adr 0948 0 Adr 0949 1 Adr 0950 3 Adr 0951 9 Adr 0952 1 Adr 0953 1 7 Adr 0954 7 24 hr Invisible Panic Adr 0955 0 Adr 0956 0 Adr 0957 1 Adr 0958 3 Adr 0959 9 Adr 0960 1 Adr 0961 1 8 Adr 0962 8 24 hr Burglary Adr 0963 0 Adr 0964 0 Adr 0965 1 Adr 0966 3 Adr 0967 13 Adr 096...

Страница 81: ... not running they remain Swinger Shunted and do not send reports Unverified Events Send Trouble Reports If this option is enabled Fire Alarm with Verification zones that have single unverified events generate an Unverified Event report Zones with the Cross Zone option enabled that have a single pulse generate an Unverified Event report Bypass Force Arm Report Routing Address 1028 Default 0 No Repo...

Страница 82: ...m trouble and restoral reports Swinger shut down for the control panel is a global function that affects all zones Swinger Shunt 33 reports are sent for Swinger Shunt of zones The Swinger Count is reset on both arming and disarming allowing Swinger Shunt to work for both non 24 hour and 24 hour zones Example Assume the Swinger Shunt option is enabled the control panel is armed and there are no ala...

Страница 83: ... not transmitted The alarm event becomes a local only event 2 The user hears a unique three long beep tone at the keypad 3 The text keypad indicates the aborted alarm on the display The LED keypad indicates the aborted alarm with a slow flash in Alarm Memory See the DS7200V2 Expert Programming Guide P N 4998153891 for more information on the Cancel Event enabled option and the Enable Alarm Event A...

Страница 84: ...t This option turns Programmable Output 2 PO 2 into a supervised siren driver If a siren or speaker is not connected the control panel generates a Siren Trouble event that can include a Siren Trouble 193 report The restoral event is reported with Siren Trouble Restore 194 See On board Output Setup on page 16 for more information Compatible speakers include D118 and D119 Speaker Drivers Send Output...

Страница 85: ...This parameter sets the siren warble frequency for non fire alarm output functions Programmable Output 2 PO 2 can be configured as a supervised horn speaker output see Global Output Options on page 84 This parameter sets the warble frequency for the alarm output functions 1 8 1 9 1 10 and 8 8 The setting chosen here does not apply to other output functions Lowering the frequency effectively raises...

Страница 86: ... 1064 0 On board Outputs 4 Adr 1065 1 Adr 1066 8 Adr 1067 5 Adr 1068 1 Adr 1069 0 Adr 1070 0 Adr 1071 0 5 Adr 1072 0 Adr 1073 8 Adr 1074 4 Adr 1075 1 Adr 1076 0 Adr 1077 0 Adr 1078 0 6 Adr 1079 0 Adr 1080 8 Adr 1081 7 Adr 1082 1 Adr 1083 0 Adr 1084 0 Adr 1085 0 7 Adr 1086 0 Adr 1087 8 Adr 1088 9 Adr 1089 1 Adr 1090 0 Adr 1091 0 Adr 1092 0 8 Adr 1093 0 Adr 1094 8 Adr 1095 10 Adr 1096 1 Adr 1097 0 A...

Страница 87: ... Output disabled Selections 0 15 Enter This Data Digit to Select Options Output Area Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No Area Assigned Output disabled Assign Output to Area 1 Assign Output to Area 2 Assign Output to Area 3 DS7240V2 only Assign Output to Area 4 DS7240V2 only This parameter assigns an area to the output Functions are only activated by keypads or zones assigned to the sa...

Страница 88: ...s at the start of Exit Delay For Steady or Pulse modes the output remains activated until exit delay ends 0 7 Exit Delay Finished until disarmed Output activates at the end of Exit Delay For Steady or Pulse modes the output remains activated until the system is disarmed 0 8 Bell Test on Close For systems programmed for closing reports the output activates when the acknowledgement for the closing r...

Страница 89: ...er installer Bell Test Follows Bell Time for Steady and Pulse modes PIN resets Follows programming for Alarm output types 1 9 Alarm Perimeter Only and Partial On Arming Modes Non fire 24 hour alarms Activated by alarm on zone when Perimeter Only and Partial On Armed or by alarm on Non fire 24 hour zone and by user installer Bell Test Follows bell time for Steady and Pulse modes PIN resets Follows ...

Страница 90: ...armed no zones are faulted 2 control panel is armed no zones are faulted 3 control panel is armed any zone is faulted Output is deactivated off when panel is disarmed any zone is faulted Output is deactivated even if the zone became faulted when panel was armed 2 14 Exit Error Bad Set Activates if zone is faulted at the end of Exit Delay or if a Bad Set condition occurs Resets when the system is d...

Страница 91: ...ates on a cancelled alarm Resets when alarm is cleared 8 10 RF Transmitter Missing Activates when any RF transmitter is missing 8 11 RF Transmitter Low Battery Activates when any RF transmitter is reporting a low battery For zone transmitters the output activates after the low battery is present for 100 hours 8 12 RF Receiver Jamming Activates when RF Jamming is present for 5 minutes 8 13 Fire Ala...

Страница 92: ...d and the output remains on 6 One Shot with Re Trigger Event When the event occurs the output turns on and remains on for the One Shot time If a new event occurs when the output is on the One Shot time is restarted and the output remains on State When the condition changes from inactive to active the output turns on and remains on for the One Shot time If the condition goes inactive the output is ...

Страница 93: ...Default See Table 31 Selections 0 Disabled 1 200 ms on board outputs only 2 1 second 3 1 minute 4 1 hour Multiply the Base with the Multiplier to determine the output s timing See Table 34 and Table 35 Multiplier Address See Table 31 Default See Table 31 Selections 0 9 Multiply the Base with the Multiplier to determine the output s timing See Table 34 and Table 35 ...

Страница 94: ...lying the Base by the Multiplier The Time Base of 200 ms in Table 34 and Table 35 is only available for on board outputs Base On Time On Time Time of Base Multiplier Off Time Off Time Base x Multiplier Tolerance 0 0 N A Always Off N A 1 200 ms 200 ms 01 99 200 ms 19 8 sec 200 ms 2 1 sec 1 sec 01 99 1 99 sec 1 sec 3 1 min 1 min 01 99 1 99 min 1 min 4 1 hr 1 hr 01 99 1 99 hr 1 hr Table 34 Pulse Mode...

Страница 95: ... 0 Addr 1191 0 2 Addr 1192 0 Addr 1193 0 Addr 1194 0 Addr 1195 0 Addr 1196 0 Addr 1197 0 Addr 1198 0 Addr 1199 0 3 Addr 1200 0 Addr 1201 0 Addr 1202 0 Addr 1203 0 Addr 1204 0 Addr 1205 0 Addr 1206 0 Addr 1207 0 4 Addr 1208 0 Addr 1209 0 Addr 1210 0 Addr 1211 0 Addr 1212 0 Addr 1213 0 Addr 1214 0 Addr 1215 0 5 Addr 1216 0 Addr 1217 0 Addr 1218 0 Addr 1219 0 Addr 1220 0 Addr 1221 0 Addr 1222 0 Addr ...

Страница 96: ...Sked Type is Auto On or Auto Off this parameter assigns an area to the Sked If the Sked Type is Output On or Output Off this parameter assigns a programmable output How the programmable output functions at Sked time is determined in Outputs on page 86 The output assigned to the Sked in this parameter can be any output The Sked overrides that function at Sked Time The Output On Off Sked function is...

Страница 97: ...Days Option 2 Sked parameter If the Every Day option is selected in the Days Option 1 Sked parameter it overrides any selection made in the Days Option 2 Sked parameter Days Option 2 Sked Address See Table 36 Default 0 Selections 0 15 Enter This Data Digit to Select Options Sked Days 2 Option 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No Option Selected Thursday Friday Saturday Sunday Use this paramete...

Страница 98: ...vent 127 DBus Tamper is generated Receiver 2 Connected Set Receiver to Address 51 Enable this option if RF Receiver 2 is connected to the control panel Set the RF receiver s address to 51 jumper setting ON See Adding RF ID Codes on page 34 for instructions See RF Transmitters and Zone States on page 75 for details on RF transmitters and zone states All status reports for the RF Receiver include th...

Страница 99: ...vents using the internal keypad character codes Non standard characters may not print correctly RS 232 Log Output using PC Compatible Codes If enabled this option outputs the events using PC compatible character codes Non standard characters are mapped to the closest matching character for display or printing If you connect a printer to the module and get unexpected results check the module output...

Страница 100: ...ult 0 Selections 0 15 Enter This Data Digit to Select Options DX8010 Access Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Disabled No DX8010 Connected Access Granted to Users with Authority Level 1 Access Granted to Users with Authority Level 2 Access Granted to Users with Authority Level 3 Access Granted to Users with Authority Level 4 Set this parameter to zero 0 if there are no DX8010 modules c...

Страница 101: ...ss RF Keypad 1 2930 RF Keypad 2 2932 RF Keypad 3 2934 RF Keypad 4 2936 Default 0 Selections 0 2 4 6 Enter This Data Digit to Select Options RF Keypad Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No Options Selected Reserved Belongs to Receiver 2 Supervised Reserved Belongs to Receiver 2 If this option is enabled RF Receiver 2 performs ID and monitoring functions for the keypad If this option is d...

Страница 102: ...lly assigned to RF Receiver 1 RF Keyfob Options Address 2939 Default 15 Selections 0 1 3 4 5 7 8 9 11 12 13 15 Enter This Data Digit to Select Options RF Keyfob Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No Options Selected Panic Enabled Alarm Output on Panic Assign O trapezoid key to Perimeter Only On Assign P key to Partial On This parameter configures all keyfobs for all areas and all PINs P...

Страница 103: ...el is armed Perimeter Only or Part On only some of the controlled zones can create an alarm If this option is selected and the zone that is tampered is a Perimeter Only or Part On zone a tamper alarm is created If the zone is not a Perimeter Only or Part On zone the tamper response depends on the setting made for the next option Tamper Alarm when Disarmed The non zone tampers are always included i...

Страница 104: ...one is faulted when the Exit zone restores the restoral is ignored Entry Exit zones might or might not be bypassed If all Entry Exit zones are bypassed and the Exit Delay time is set to 0 disabled the control panel cannot be armed All On Exit Terminator Zone Options Address 3410 Default 0 Selections 0 15 Enter This Data Digit to Select Options Exit Terminator Zone Options 0 1 2 3 4 5 6 7 8 9 10 11...

Страница 105: ...3412 entry x 16 Address 3413 entry Confirmation Alarm Timer setting For example use the following steps to set the Confirmation Alarm Timer to 30 minutes 1 Enter 1 in Address 3412 1 x 16 16 2 Enter 14 in Address 3413 16 14 30 Commonly used time settings 1 14 30 minutes 1 x 16 16 14 30 minutes 2 13 45 minutes 2 x 16 32 13 45 minutes 3 12 60 minutes 3 x 16 48 12 60 minutes An entry of 0 0 disables t...

Страница 106: ...ol panel advances to the next report it resets its count and sends the new report up to ten times or until it is acknowledged If no one acknowledges the report after ten tries the control panel hangs up and calls again If two phone numbers are programmed for the destination the second phone number is called The control panel follows the normal event phone routing For each event the control panel t...

Страница 107: ...nding of reports in BSIA Fast Format The control panel continuously monitors the outputs assigned to the reporting channels When there is a change to report the report is sent The event does not have to be stored in the log or programmed for routing to the BSIA Fast Format s destination When an event is placed in the log and its destination is the BSIA Fast Format destination the control panel mar...

Страница 108: ... 0 0 Channel 7 Addr 3470 3471 0 0 Channel 8 Addr 3472 3473 0 0 Group 3 Addr 3432 0 Channels 1 4 Addr 3438 0 Channels 5 8 Addr 3439 0 Channel 1 Addr 3474 3475 0 0 Channel 2 Addr 3476 3477 0 0 Channel 3 Addr 3478 3479 0 0 Channel 4 Addr 3480 3481 0 0 Channel 5 Addr 3482 3483 0 0 Channel 6 Addr 3484 3485 0 0 Channel 7 Addr 3486 3487 0 0 Channel 8 Addr 3488 3489 0 0 Group 4 Addr 3433 0 Channels 1 4 Ad...

Страница 109: ...eight channels within each group can be assigned to an output function type the same way the on board and off board outputs are assigned To assign Channel 1 in Group 1 to Fire Channel 1 would be assigned to Output Function Type 8 13 enter 8 in Address 3442 and 13 in Address 3443 All available output types may be used Use Table 32 to assign output function types to the each reporting channel Basic ...

Страница 110: ...prepare to accept the message The Digits to Dial Field ends with a Field Terminator 0 The Format Field follows the Digits to Dial Field It defines what information follows the account number in the paging message The Format Field ends with a Field Terminator 0 The End Page Field follows the Format Field The digits you enter in this field are sent after the paging message For many paging services a...

Страница 111: ...mat when 3 is entered into the appropriate reporting format address See Format for Destination 1 2 on page 43 for more information An additional format selection of 11 is available to include ASCII text with the SIA event codes If the SIA event includes a zone number as one of its parameters and the zone represents one of the control panel s 40 locations the control panel sends the zone s programm...

Страница 112: ...ptions parameter to 3 refer to page 115 IP Address 1 2 for Destination 1 2 Address Range IP Address 1 Destination 1 0000 0031 IP Address 2 Destination 1 0032 0063 IP Address 1 Destination 2 0066 0097 IP Address 2 Destination 2 0098 0129 Default All zeroes 0 Selections 000 000 000 000 to 255 255 255 255 Each routing destination can be configured as a phone number or an IP address When entering an I...

Страница 113: ...d Enable Alternate Communication Select this option to enable network communication You must enter at least one IP address as a routing destination See IP Address 1 2 for Destination 1 2 on page 112 for more information Enable Anti Replay Anti replay prevents unauthorized messages from being sent to the ARC and being recognized as having originated from the control panel Enable this option to use ...

Страница 114: ...a value between 0 and 15 for each alternate communication wait time address Alternate Communication Heartbeat Period Address Range IP Address 1 Destination 1 3510 3513 IP Address 2 Destination 1 3518 3521 IP Address 1 Destination 2 3526 3529 IP Address 2 Destination 2 3534 3537 Default 0 0 7 5 Selections 0 to 1275 seconds Use this parameter to set the rate that the DX4020 polls the Alarm Receiving...

Страница 115: ...This Data Digit to Select Options Network Interface Module Options 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 No Alternate Communication Enable Alternate Communication Include IP Address Reserved Reserved Enable Alternate Communication Select this option to supervise the connection between the control panel and the network interface module DX4020 The network interface module s DIP switch address must b...

Страница 116: ... 1 e Assign a zone number in Addresses 0729 0730 if the zone number must be different than the location number 2 Enter the location number in DACM Location Assignment For this example enter 0 in Address 3546 and 5 in Address 03547 This assigns the control panel s Location 5 to DACM 1 3 Assign global options in Address 3562 see DACM Global Options on page 117 The entry you make here affects all DAC...

Страница 117: ...mmediately Only the user who started the arming process can confirm arming If this option is disabled verifying a user at the DACM reader during Exit Delay cancels the arming process the system does not arm Any User Confirms Arming If this option is enabled any user can confirm system arming If this option is disabled only the user who started the arming process can confirm arming This option only...

Страница 118: ...l have to know which keys were pressed Perimeter Only or 2 for Perimeter Only 3 for Partial On I armed the system All On but it keeps changing to Perimeter Only The Perimeter Only If No Entry Exit arming option is enabled see Arming Options 1 on page 54 When the control panel was armed nobody faulted an Exit Delay zone Therefore the control panel did not arm those internal zones See see Arming Opt...

Страница 119: ... The PK32 has not been enabled in the control panel See Local Programming Options in the DS7200V2 Expert Programming Guide P N 4998153891 Address 0257 Make sure the selection you make enables the PK32 The off board zones I added to the system display as missing The Device Location parameter is not correctly programmed If the off board zones are RF wireless zones enable the RF Receiver at Address 1...

Страница 120: ...perly connected to the control panel See DX4020 Wiring on page 30 Make sure the DX4020 s DIP switches are set to Address 134 see DX4020 Addressing on page 28 Make sure your selection for Address 3541 includes the Alternate Communication Interface at Address 134 option See Network Interface Module Options on page 115 See the DX4020 Installation Guide P N 49522 for additional configuration requireme...

Страница 121: ... 2 Programmed Destination 1 Destination 2 Destination 1 Destination 2 Attempt Ph IP 1 Ph IP 2 Ph IP 1 Ph IP 2 Attempt Ph IP 1 Ph IP 2 Ph IP 1 Ph IP 2 1 X 1 X 2 X 2 X 3 X 3 X 4 X 4 X 5 CF 5 CF 6 6 7 7 8 8 9 9 10 10 61 2 Destination 2 Only Phone IP Address 1 Programmed Phone IP Address 1 and 2 Programmed Destination 1 Destination 2 Destination 1 Destination 2 Attempt Ph IP 1 Ph IP 2 Ph IP 1 Ph IP 2 ...

Страница 122: ... 1 Ph IP 2 Attempt Ph IP 1 Ph IP 2 Ph IP 1 Ph IP 2 1 X 1 X 2 X 2 X 3 X 3 X 4 X 4 X 5 CF 5 CF 1 X 1 X 2 X 2 X 3 X 3 X 4 X 4 X 5 CF 5 CF Phone IP Address 1 and 2 Programmed for Destination 1 Phone IP Address 1 Programmed for Destination 2 Phone IP Address 1 Programmed for Destination 1 Phone IP Address 1 and 2 Programmed for Destination 2 Destination 1 Destination 2 Destination 1 Destination 2 Attem...

Страница 123: ... A Area Number Zn Zone Number Dv Device Number Ln Phone Line Number Mn Minutes till Auto Arm Sked Cd User Code Number Op Output Number Ks Keyswitch Number U User Number Communication status for Routing Destinations 1 2 Table 45 History Log Display Descriptions The following table defines the communication status values that may appear in the history log Value Description Probable Cause A Aborted A...

Страница 124: ...Panic Panic Alarm ri area PA loop 120 Panic Alarm Panic Visible Zone Type 6 Visible Panic Emergency Key 3 06 Alarm Invisible Holdup Alarm ri area HA loop 120 Panic Alarm Panic Invisible Zone Type or ABC key programmed for panic response 7 Invisible Panic Emergency Key 3 07 Alarm 24 hr Burg Burglary Alarm ri area BA loop 133 24 Hr Safe Alarm Burglary Zone Type 8 Burglary 15 Door 3 08 Alarm Cntrl Dl...

Страница 125: ...Dead Battery Restoral from missing battery 12 R S 26 Bypass Fire User Fire Bypass ri area FB loop 571 Fire bypass Selective bypass by user fire zone types 1 Fire 2 Fire with Alarm Verification 15 27 Bypass Fire RPS Fire Bypass ri area FB loop 571 Fire bypass Selective bypass by RPS fire zone types 1 Fire 2 Fire with Alarm Verification 28 Bypass Ctrl User Burglary Bypass ri area BB loop 570 Zone Se...

Страница 126: ... Exit Delay by RPS 45 Cls All Dly Tel Remote Closing ri area CQ 253 407 Remote Arm Disarm System turned All On with Entry Exit Delay by Telephone 10 46 Cls All Dly Usr Closing Report ri area CL user 401 O C by User System turned All On with Entry Exit Delay by User 10 47 Cls All Dly RPS Remote Closing ri area CQ 254 400 Open Close System turned All On with no delay instant by RPS 48 Cls All Dly Us...

Страница 127: ...r Arm ri area NF 254 456 Partial Arm System forced Perimeter Only with no delay instant by RPS 67 Frc Prt Dly Usr Forced Perimeter Arm ri area NF 254 456 Partial Arm System forced Perimeter Only with no delay instant by User 10 68 Reserved 69 Comm Fail Communications Fail rg destination YC 354 Failure to communicate event Report failed to reach routing destination 12 R S 70 CommFail AltComm Commun...

Страница 128: ... Instl Mode Start Local Program LB 466 Service On Premises Installer PIN entered Installer mode accessed 11 R 83 Instl Mode End Local Programming Ended LX 466 Service Off Premises Installer mode exited 11 R 84 Log Overflow Log Overflow JO 624 Event Log Overflow Panel log overflow condition Oldest events being overwritten 12 R 85 Log Threshold Log Threshold JL 623 Event Log Panel log reached thresh...

Страница 129: ...on Bus device 12 R S 106 Output Reset Usr Relay Open id user RO output 320 Sounder Relay Output Reset by User 16 R 107 Output Reset Tmr Relay Open id 252 RO output 320 Sounder Relay Output Reset by Sked Timer 16 R 108 Output Reset RPS Relay Open id 254 RO output 320 Sounder Relay Output Reset by RPS R 109 Output Set Usr Relay Close id user RC output 320 Sounder Relay Output Set by User 16 R 110 Ou...

Страница 130: ...EJ SDI address 341 Exp Module Tamper Data Bus Device Tamper Restoral 12 R S 129 DBus Fault Expansion Trouble ET SDI address 330 System Peripheral Trouble Fault Trouble detected on Data Bus Device 12 R S 130 DBus Fault Rstl Expansion Restoral ER SDI address 330 System Peripheral Trouble Data Bus Device Fault Trouble condition cleared 12 R S 131 DBus OverCurrent Overcurrent Trouble pi SDI address YI...

Страница 131: ...r Trouble Restore ri area TJ 380 Sensor Trouble Restoral from fault trouble condition on Tamper or Voice Active zone types 4 Tamper 8 147 Rstrl Flt Emerg Emergency Trouble Restore ri area QJ loop 380 Sensor Trouble Restoral from fault trouble condition on Emergency zone type 5 Emergency 8 148 Rstrl Flt Panic Panic Trouble Restore ri area PJ loop 375 Panic Zone Trouble Restoral from fault trouble c...

Страница 132: ...s or Aux power outputs 12 R S 163 Grnd Fault Rstl Equipment Fail Restoral IR 0 310 Ground Fault Ground fault condition cleared 12 R S 164 First Open Opening Report OP user 400 Open Close Panel is configured for multiple area first to open last to close functions See Open Close Reporting Options on page 56 First area has opened 10 165 Last Close Closing Report CL user 400 Open Close Panel is config...

Страница 133: ...ry Restoral ri 0 XR user 384 RF Low Battery Low battery condition on RF Keyfob restored 9 R 183 Default PINS Local Event Only Local Event Only Installer or User PINS have not been changed from default 184 Default PINS Rstl Local Event Only Local Event Only Installer or User default PINS have been changed 185 Bad Set Exit Error Ri area EE user 454 Failed to Close Bad Set condition 3 186 Confirmed A...

Страница 134: ...maged or disconnected Data Bus Missing Device The Data Bus device set to the address shown in the display is missing or has stopped responding View the control panel s history log 8 5 to see which device went missing Data Bus Tamper Device The tamper on the Data Bus set to the address shown in the display is open View the control panel s history log 8 5 to see which device experienced a tamper con...

Страница 135: ...t System Reset key or 4 7 Check System Troubles 4 View Alarm Memory 4 0 System Test 4 1 View System Trouble 4 2 Remote Program 4 3 Walk Test 4 4 Change Date Time 4 5 View Zone Trouble 4 8 Keypad Adjust 4 9 Move to Area 5 0 Extend Auto On Time 5 1 Change Skeds 5 2 Renew One time PINs 5 3 Change Outputs 5 4 Change PIN 5 5 Change Another User s PIN 5 6 1 Change Another User s PIN Authority Level 5 6 ...

Страница 136: ...y DX4010i DX4010 25 x Qty 25 x Qty 25 x Qty DX4020 84 1102 x Qty 84 1102 84 1102 x Qty 84 1102 84 1102 x Qty 84 1102 RF3227E 30 x Qty 30 x Qty 30 x Qty Sounders Connected to PO 2 D118 8 Ω Speaker 0 x Qty 0 x Qty 330 x Qty Ratings of Other Devices in System that are not Shown Above x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty x Qty Total A Total B Total C 1 Cu...

Страница 137: ...nformation received and compares its sum to the transmitted checksum number If the numbers do not match the transmission is in error Confirmed Alarm Alarm conditions were reported by two or more independent detectors which are configured so that there is a high probability that a genuine intrusion or a genuine attempted intrusion occurred A sequentially confirmed alarm as defined by DD234 2002 Cro...

Страница 138: ...cessary to make the number odd or even Parameter Each program parameter sets a specific value or chooses an option Partial On A user defined subset of the zones that arm Partial On with No Entry Instant is an option Perimeter Only An installer defined subset of the zones that arm Perimeter Only with No Entry Instant is an option PIN Personal Identification Number A unique number issued at the time...

Страница 139: ...DS7200V2 UK Installer s Guide Copyright 2007 Bosch Security Systems Inc P N 4998152533 02 Page 139 Notes ...

Страница 140: ...ay Alarm Output 47 Disabling a Zone Wired or RF 75 Door Access Control Module Global Options 117 Keypad DACM Area Options 67 116 Location Assignment 117 Overview 31 Supervision 32 Wiring 31 DTMF Pulse Dialing 44 Duress Report Routing 71 Reporting Options 70 DX2010 Address Programming 21 Status LED 22 Supervision 22 Wiring 19 DX3010 Address Programming 25 Configuration 22 Relay Outputs 22 Supervisi...

Страница 141: ...put 77 Answering Machine Bypass Options 54 Any User Confirms Arming 117 Assign O Key 102 Assign P Key 102 Belongs to Receiver 2 101 Call Barring 44 Call RPS at Test Time 51 Closing Reports Enabled 56 Defer Test Report 51 Disable RF Loop Tamper 98 Display at Call for Service Interval 49 Display at System Inactive Interval 49 Do Not Wait for Dial Tone 44 Enable Alarm Output Arming Beep 84 Enable All...

Страница 142: ...vision 18 Routing Destinations 42 RPS Answer Ring Count 46 S Sensor Monitor Time 83 SIA 300 with Text Blocks 111 Siren Output Volume 85 Siren Warble Frequency 85 Sked Configuration Assign Area or Output Sked 96 Days Option 1 Sked 97 Days Option 2 Sked 97 Time Sked 96 Type Sked 95 Supervision DX2010 22 Supervision Keypad 15 RF3227E 18 Supervision DX3010 25 Supervision DX4010i DX4010 27 Supervision ...

Отзывы: