Bosch DS304 Скачать руководство пользователя страница 4

Bosch Security Systems | 1/05 | 4998122424F

EN | 

4

5.0

Configuration

5.1

Program Jumper for the S/U Control
Terminal

Use the S/U control terminal as an alarm memory
control input by setting the jumper in the upper position
as shown in 

Item 1 

of 

Figure 6

.

Use the S/U control terminal as an electronic alarm
output (open collector) by setting the jumper in the
lower position as shown in 

Item 2

 of 

Figure 6

.

5.2

User DIP Switches

5.3

Adjusting Sensitivity

Table 1:     Sensitivity Settings 

 

DIP Switch 2 OFF 

 

Standard Sensitivity (Default):  

Recommended for maximum false 
alarm prevention. 

Tolerates environmental extremes. 

Not recommended for curtain 
patterns. 

DIP Switch 2 ON 

 

Intermediate Sensitivity:  

Recommended for any location 
where an intruder is expected to 
cover only a small portion of the 
protected area, or when you want 
improved catch performance. 

Does not tolerate normal 
environments. 

 

5.4

LED Setup Without S/U and WT
Remote Control Panel Inputs

Table 2:     LED Setup Without Control Panel Inputs 

 

 

DIP Switch Settings 

LED 
Operation 

User DIP Switch 1 
Walk Test 

User DIP Switch 3 
Set/Unset 

Disable LED 

Any 

ON 

 

Enable LED 

OFF (default) 

 

OFF (default) 

 

 

5.0 Configuration

Figure 7:

User DIP Switches

3

1

2

1

2

3

OPEN

1 - Walk Test polarity (Refer to 

Section 5.4 LED

Setup Without S/U and WT Remote Control
Panel Inputs.

)

2 - Sensitivity (Refer to 

Section 5.5 Setup for

Remote Control Alarm Memory and LED
Operation Using S/U and WT Inputs.

)

3 - Set/Unset polarity (Refer to 

Section 5.4.

)

1 - Alarm memory control input

2 - Electronic alarm output

Figure 6:

Program Jumper Settings

2

1

S/U

AL

S/U

AL

DS304

| Installation Instructions |

Содержание DS304

Страница 1: ...DS304 EN Installation Instructions Passive Infrared PIR Detector ...

Страница 2: ...nd lifting the circuit board up and out of the enclosure base 3 Remove the mirror by sliding it out of its tracks 4 Remove an appropriate wiring knockout 5 To surface or corner mount go to Section 2 1 Surface or Corner Mounting To bracket mount go to Section 2 2 Bracket Mounting on page 3 2 1 Surface or Corner Mounting 1 Remove the knockout holes for either surface or corner mounting 2 Using the e...

Страница 3: ...side the enclosure Seal the wire entrance with the plug provided Figure 3 Mirror Angle Adjustment X Y 2 0 6 5 2 3 7 5 2 6 8 5 Broad 20 6 35 10 Curtain 40 12 70 20 10 6 4 2 12 8 4 2 14 10 6 4 Y m ft X m ft X maximum range Y mounting height Figure 5 Terminal Strip Connections 4 5 6 7 8 9 10 11 1 2 3 1 SH Shield optional Connection for ground wire from shielded cable 2 S U Set Unset optional Use as a...

Страница 4: ...d for any location where an intruder is expected to cover only a small portion of the protected area or when you want improved catch performance Does not tolerate normal environments 5 4 LED Setup Without S U and WT Remote Control Panel Inputs Table 2 LED Setup Without Control Panel Inputs DIP Switch Settings LED Operation User DIP Switch 1 Walk Test User DIP Switch 3 Set Unset Disable LED Any ON ...

Страница 5: ...r 4 sec Unset ON No alarms OFF Transition from Unset to Set OFF or ON Memory cleared OFF 6 0 Remote Control Operation 7 0 Setup and Walk Testing Enable the LEDs before performing a Walk Test 1 Replace the cover and insert the cover tamper screw if desired 2 Apply power to the unit 3 Wait at least 2 min for the detector to stabilize and no motion is detected Figure 8 4 Watch the LED as you walk to ...

Страница 6: ...t polished surface view mirror segment for pattern reference 0 m A C D E B 2 0 8 16 2 0 8 16 3 2 0 m 0 m 2 m 21 m B D C E A 1 0 m 1 9 m 1 9 m 21 m 1 Top view 2 Side view mirror adjusted to 6 3 Front polished surface view mirror segment for pattern reference Figure 9 Wide Angle Coverage A B C D E F G H I J K L M N 2 0 8 16 2 0 8 16 Q P O 3 E G F I H C D A B N M L K J P Q O 1 0 m 5 35 m 0 m 5 35 m 1...

Страница 7: ...safety extra low voltage SELV circuit only Optional Electronic Alarm Output alternate use of S U Terminals Inactive Open collector output Active Switch low through 1 kΩ Tamper Contact 28 V 125 mA Connect to a SELV circuit only Connect the tamper circuit to a 24 hour protection circuit Control Inputs Walk Test S U LOW 1 5 V or less HIGH 3 5 V or more Coverage Wide Angle Mirror 11 m x 11 m Curtain M...

Страница 8: ...Bosch Security Systems 130 Perinton Parkway Fairport NY 14450 9199 USA www boschsecurity us Customer Service 800 289 0096 Technical Support 888 886 6189 2004 Bosch Security Systems 4998122424F ...

Отзывы: