10
Top
outlet
Top
screw
location
Square
slot
bottom fixing
screws locations
Top
screw
location
Rear
outlet
7 1/2"
W
Z
K
Knockouts
(junction
box)
Wall Mount Installation
Note: see below if cabinet installation is
preferred
4.
After the hood installation height has been
determined draw a horizontal line at a
distance above the cooktop equal to the
desired hood installation height plus
7- 1/
2”
. See also Figure 6a.
5.
Find the centerline of the cooktop.
Draw a vertical line along this centerline up to
the horizontal line drawn in step 1 and draw a
vertical line right and left at a distance of
12-5/8”
to determine the mounting location
of the mounting hooks shipped with the hood.
6.
Fit two mounting hooks on the wall to hang the
hood through the provided slots (2 wall
2 hooks + 2 screws 5x35).
7.
Run 8” Duct , long enough to reach the
transition once the hood has been installed plus
1 1/2” inch to connect ductwork.
Fix Duct to transition with screws and seal with
tape.
8.
Remove 1 of 2 knockouts and install 1/2”
conduit connector in j-box.
9.
Hang the hood and adjust its position through
the screws on the hooks.
10.
Fix the hood to 4 additional point,2 on upper
side, 2 on lower side (use 4 wall a 4
w 4 screws 5x35.
11.
Vertical discharge
Cabinet Installation:
Note: see above if wall mount installation is
preferred
Note: distances on Table 3.
4.
Find the centerline of the cabinet bottom. Draw
a line along this centerline from rear to front of
the cabinet.
5.
Draw two lines, one at a
K
distance from the
wall, the other one at a
Z
distance from the
previous line.
Mark 4 points , two along each line at a distance
of half
W
from the center line, to determine the
screw locations.
6.
Fit 4 screws on cabinet bottom do not tighten
completely but leave a space of about 1/2” from
cabinet bottom surface and head screws.
7.
Run 8” Duct , long enough to reach the
transition once the hood has been installed plus
1 1/2” inch for connect ductwork.
8.
Remove 1 of 2 knockouts and install 1/2”
conduit connector in j-box.
9.
Hang the hood on screws through side slots
provided on hood top.
Tighten the four screws.
Note:
If possible fix the hood on the wall at 4
additional point (2 on upper side, 2 on lower
side).
10.
From the inside of the cabinet attach the
transition on upper outlet (vertical discharge -
see also „Assembly of the 8” Transition“ on
previous pages)
HOOD WIDTH
DIM. "W" DIM. "K"
DIM. "Z"
30"
29 - 1/8"
2 - 1/2"
7 - 1/16"
36"
35 - 1/16" 2 - 1/2"
7 - 1/16"
Table 3
Side slot x 4
Figure 6b
K
CL
Z
W
CL
Screw for
cabinet
bottom
installation
Hook for wall
installation
Adjusting
screw
25 3/16"
7 1/2"
Bottom of the Hood
12 5/8" 12 5/8"
Figure 6a
Содержание DPH30352U
Страница 1: ...Bosch ventilation installation manual DPH36352UC DPH30352UC ...
Страница 7: ...7 TOTAL of both columns ...