System events
Figure 6.30: System events
Use this menu to setup how the system reacts to different system events.
–
Event type: choose from disk error, no disk, no space on disk, NET disconnection, IP
conflict, MAC conflict.
–
Enable: select to enable the system event.
–
Alarm out: select the alarm activation output port(s) (maximum of 3 on DIVAR 3000; 6 on
DIVAR 5000).
–
Latch: set a delay time (from 10 seconds (default) to 300 seconds) before the system
automatically turns off the alarm and the activated output after the external alarm is
cancelled.
–
Show message: system will pop up a message on the local screen to alert you when an
alarm occurs.
–
Alarm upload: system will upload the alarm signal to the network.
–
Send email: system will send an email to alert you when an alarm occurs.
–
Buzzer: the buzzer alerts you when an alarm occurs.
6.14