background image

DIVAR IP all‑in‑one 7000 2U | DIVAR IP
all‑in‑one 7000 3U

DIP‑7380‑00N | DIP‑7384‑8HD | DIP‑7388‑8HD | DIP‑738C‑8HD |
DIP‑73G0‑00N | DIP‑73G8‑16HD | DIP‑73GC‑16HD

en

User manual

Содержание DIP-7380-00N

Страница 1: ...DIVAR IP all in one 7000 2U DIVAR IP all in one 7000 3U DIP 7380 00N DIP 7384 8HD DIP 7388 8HD DIP 738C 8HD DIP 73G0 00N DIP 73G8 16HD DIP 73GC 16HD en User manual ...

Страница 2: ......

Страница 3: ...ting as pure video recording system 9 4 1 3 Operating as iSCSI storage expansion 9 5 Upgrading and updating software 11 6 Remote connection to the system 12 6 1 Protecting the system from unauthorized access 12 6 2 Setting up port forwarding 12 6 3 Choosing an appropriate client 12 6 3 1 Remote connection with Operator Client 12 6 3 2 Remote connection with Video Security App 12 6 4 Installing an ...

Страница 4: ...an access control protected area in order to avoid physical manipulation of the system Windows online update functionality or the corresponding monthly roll up patches for offline installation can be used to install OS security updates Limiting local network access to trusted devices is strongly suggested Details are described in the Technical note Network Authentication 802 1X and in the Bosch IP...

Страница 5: ...VMS or VRM system which runs on a different hardware i Notice Recorded video streams need to be configured in a way that the maximum bandwidth of the system BVMS VRM base system plus iSCSI storage expansions is not exceeded DIVAR IP Software Center DIVAR IP Software Center is the central user interface for software setup upgrade and operation mode selection After installation of DIVAR IP Software ...

Страница 6: ...operating system of empty units loaded with third party hard drives will start normally but the added hard drives must be configured with the MegaRAID Storage Manager application prior to initial software setup For further details refer to the Installation manual All DIVAR IP systems are preconfigured with a default IP address and with default iSCSI settings IP Address automatically assigned by DH...

Страница 7: ... Agreement are displayed 4 Click Accept to accept the license terms and wait until Windows restarts This can take several minutes Do not turn off the system After the restart the Windows logon page is displayed 5 Set a new password for the administrator account BVRAdmin and confirm it Password requirements Minimum 14 characters At least one upper case letter At least one lower case letter At least...

Страница 8: ...tore boschsecurity com 4 1 Choosing operation mode In the DIVAR IP Software Center application you must choose the desired operation mode to configure your DIVAR IP all in one 7000 system i Notice Changing the operation mode after installation requires a full factory reset 1 2 1 Selection window 2 Main window Refer to Operating modes page 5 4 1 1 Operating as full video recording and management sy...

Страница 9: ...g the software packages which will be installed 3 Click Install to continue The installation of the software packages starts This can take several minutes Do not turn off the system and do not remove the storage media Note If an error occurs during installation click Finish This restarts the system After restart update the respective software packages and proceed with setup 4 After all packages ha...

Страница 10: ...000 3U 2021 10 V02 DOC User manual Bosch Security Systems B V 5 Add the system as an iSCSI storage expansion to an external BVMS or VRM server using BVMS Configuration Client or Configuration Manager i Notice For further details refer to the BVMS or Configuration Manager documentation ...

Страница 11: ...The upgrade will save all your settings update the software and restart the system 4 Click Install to continue The installation of the software packages starts This can take several minutes Do not turn off the system and do not remove the storage media After the installation is completed the system restarts Updating software To update the installed software 1 Download the desired software packages...

Страница 12: ... now accessible from the Internet 6 3 Choosing an appropriate client This chapter describes the ways that allow remote connection to a DIVAR IP system through the internet There are 2 ways to make a remote connection Remote connection with Operator Client page 12 Remote connection with Video Security App page 12 i Notice Only use BVMS Operator Client or Video Security App in the version that match...

Страница 13: ...e server To install Bosch VMS Enterprise Management Server on a separate server 1 Download the BVMS installer from the product page 2 Copy the BVMS installer to the server that should act as an Enterprise Management Server 3 Double click the installer program then accept the security message 4 In the Welcome dialog box clear all check boxes except Enterprise Management Server and Configuration Cli...

Страница 14: ...ng the unit Following procedure describes how to restore the factory default image To restore the unit to factory default image 1 Start the unit and press F7 during the BIOS power on self test to enter Windows PE The Recovery menu is displayed 2 Select one of the following options Initial Factory Setup all data on system will be lost This option deletes data on all HDD partitions and overwrites th...

Страница 15: ...manual 2021 10 V02 DOC 3 The unit starts from the recovery media If the setup is successful press Yes to restart the system 4 Windows performs the initial setup of the operating system After Windows has completed the setup the unit restarts 5 After the restart of the unit the factory settings are installed ...

Страница 16: ...vailable upgrade packages in the Download Area of Bosch Security and Safety Systems under https downloadstore boschsecurity com 8 2 Support services and Bosch Academy Support Access our support services at www boschsecurity com xc en support Bosch Security and Safety Systems offers support in these areas Apps Tools Building Information Modeling Warranty Troubleshooting Repair Exchange Product Secu...

Страница 17: ...DIVAR IP all in one 7000 2U DIVAR IP all in one 7000 3U Additional information 17 Bosch Security Systems B V User manual 2021 10 V02 DOC ...

Страница 18: ...18 Additional information DIVAR IP all in one 7000 2U DIVAR IP all in one 7000 3U 2021 10 V02 DOC User manual Bosch Security Systems B V ...

Страница 19: ......

Страница 20: ...Bosch Security Systems B V Torenallee 49 5617 BA Eindhoven Netherlands www boschsecurity com Bosch Security Systems B V 2021 202110281647 ...