DIVAR IP 7000 (2U)
Maintenance | en
41
Bosch Sicherheitssysteme GmbH
Installation Manual
2016.07 | V2 | DOC
1
Hard drive carrier
2
SATA hard drive
6.
Replace the hard drive carrier into the chassis bay. Make sure that the hard drive carrier
handle is completely closed.
Notice!
We recommend using the respective Bosch hard disk drives. The hard disk drives as one of
the critical component are carefully selected by Bosch based on available failure rates. HDD –
not delivered from Bosch – are not supported. Information on supported HDDs can be found
in the datasheet in the Bosch Online Product Catalog.
See also
–
Installing a hard drive into a front drive bay, page 41
10.4.3
Installing a hard drive into a front drive bay
To install a hard drive into a hard drive bay:
1.
Push against the upper part of the hard drive handle.
2.
Push the hard drive horizontally into the hard drive bay, orienting the hard drive so that
the release button is on the right.
3.
Push the hard drive carrier into the bay until the handle retracts and the hard drive clicks
into the locked position.
10.5
Identifying a faulty SSD drive
The system provides tools for hard drive monitoring that are pre-installed on the system.
Use the Intel Rapid Storage tool to identify a faulty SSD drive, if the RAID 1 mirror that holds
the operation system partition is running in degraded mode.
To identify and replace SSD drives:
1.
Turn on the unit and log on as user BVRAdmin. The default screen is displayed.
2.
Double-click the
Intel Rapid Storage
icon on the screen.
3.
Check the status of the listed SSD drives and note the port numbers.
–
SATA port 0: refers to the SSD located in the left tray
–
SATA port 1: refers to the SSD located in the right tray
4.
After you have identified the faulty SSD drive, open the corresponding tray on the back of
the system and replace the SSD drive.
See also
–