28
en | Configuration
Dinion Day/Night Camera
F.01U.163.823 | v1.0 | 2010.01
Installation and Operation manual
Bosch Security Systems
Adjustment procedure DC-iris Lens
1.
Unlock the back focus locking button.
2.
Access the
Lens Wizard
menu.
3.
Set Back Focus Now
is highlighted in the menu.
4.
Turn the back focus adjustment as required.
5.
Lock the back focus locking button.
6.
Exit the menu.
Adjustment procedure Manual-iris Lens
1.
Unlock the back focus locking button.
2.
Adjust the lens to the maximum lens opening.
3.
Turn the back focus adjustment as required.
4.
Lock the back focus locking button.
5.
Adjust lens opening to suit scene.
Adjustment procedure Video-iris Lens
1.
Unlock the back focus locking button.
2.
Access the
Lens Wizard
menu.
3.
Set Back Focus Now
is highlighted in the menu.
4.
Turn the back focus adjustment as required.
5.
Lock the back focus locking button.
6.
Select
Set LVL
in the menu; the
Level
bar appears.
7.
Point the camera at the scene it will be mostly viewing.
8.
Adjust the level potentiometer located on the lens until the
Level
bar is in the central position.
9.
Exit the menu.
Set LVL
Only for video-iris lenses.
Adjust the level control on the lens to
center the level detector indicator (see
below).
EXIT