background image

Bosch Security Systems | 2003-08 | Version 2

EN

 | 3

LTC 0335 & LTC 0355

 | Installation Manual

FCC INFORMATION

This equipment has been tested and found to comply with the limits 
for a Class B digital device, pursuant to part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment 
generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no 
guarantee that interference to radio or television reception, which can 
be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the 
following measures:

Re-orient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from 
that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for 
help.

CAUTION

Any changes or modifications to construction of this 
device that are not expressly approved by the party 
responsible for compliance could void the userfs authority 
to operate the equipment.

Содержание Dinion LTC0335/20

Страница 1: ...e Noir et Blanc FR Installationsanleitung Digitale Schwarz Weiß Kamera DE Installatiehandleiding Digitale Zwart Wit Camera NL Manual de instalación Cámara Digitales de Blanco y Negro ES Manuale d installazione Videocamera Digitale in Blanco e Nero IT Manual de Instruções Câmara Digital Monocromática PT ZH ...

Страница 2: ...eat including amplifiers DANGER The lighting flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk to persons WARNING The exclamation point within an equilateral triangle is intended to alert the user to the presence of importan...

Страница 3: ...g brackets and housings specified or recommended by the manufacturer 10 Unplug the apparatus during lightning storms and when unused for extended periods 11 Do not attempt to service this unit yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 12 Servicing is required when the apparatus does not function in...

Страница 4: ... communications However there is no guarantee that interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a...

Страница 5: ...ock selectable Shutter Auto Flickerless Off selectable CCIR 1 50 1 500000 EIA 1 60 1 600000 Autoblack On Off selectable AGC On 0 21 dB Off 0 dB selectable BLC On Off selectable Lens mount C and CS compatible ALC Video iris or DC iris auto detect Power supply LTC 03x5 10 20 12 to 28 VAC or 11 to 36 VDC LTC 03x5 50 60 100 to 230 VAC Power consumption 4 W Dimensions HxWxL 58 x 66 x 122 mm 2 28 x 2 6 ...

Страница 6: ...lens connector male These Instructions Note If equipment appears to have been damaged during shipment repack it in the original packaging and notify the shipping agent or supplier CONNECTION Power Low voltage High voltage CCIR Eur EIA USA CCIR Eur EIA USA Standard resolution LTC 0335 10 LTC 0335 20 LTC 0335 50 LTC 0335 60 High resolution LTC 0355 10 LTC 0355 20 LTC0355 50 LTC 0355 60 LTC 03x5 10 a...

Страница 7: ... cut back 10mm 0 4 of insulation Composite Video LENS MOUNTING Video iris and DC iris lenses are recommended for the best picture performance The camera automatically detects the type of lens used and optimizes performance accordingly A spare male lens connector is provided if required Pin Video iris lens DC iris lens 1 Supply 11 V 50 mA max Damp 2 Not used Damp 3 Video signal 1 Vpp 1 kΩ Drive 4 G...

Страница 8: ...h C and CS mount lenses 1 Unlock the back focus locking button 2 Turn the back focus adjustment as required See Note 1 3 Lock the back focus locking button Notes 1 The camera s unique Lens Wizard allows focusing to optimize picture sharpness in both bright and low level lighting The lens wizard can be found in the Installer menu CAUTION To avoid damaging the CCD sensor when using a C mount lens tu...

Страница 9: ...remains in focus throughout the entire zoom range of the lens See Advanced Set up MOUNTING THE CAMERA The camera can be mounted from the top or bottom Note The BOTTOM mounting is isolated from ground ADVANCED SET UP The camera will normally give an optimal picture without the need for further adjustments However for special circumstances advanced set up options are available CAUTION Do not point t...

Страница 10: ...1 5 seconds to open the Installer menu Use the up or down keys to scroll up or down through a menu Use the left or right keys to move through options or to set parameters When in a menu quickly pressing the menu select key twice restores the selected item to its factory default To close all menus at once from any menu select the Exit item and hold down the menu select key until the menu display di...

Страница 11: ...GC MENU SHUTTER AES AGC ON AUTOBLACK ON EXIT LENS WIZARD DETECTED LENS VIDEO SET BACK FOCUS NOW SET LVL EXIT LENS WIZARD DETECTED LENS DCIRIS SET BACK FOCUS NOW EXIT INSTALLER VERSION 00 0010 XX LENS AUTO SPEED FAST WIZARD DEFAULTS EXIT COAX COMM ON Press the menu button Main Menu Shutter AGC Menu Press the menu button for more than 5sec Installer Menu Lens Wizard Menus ...

Страница 12: ...ver exposed this is normal SYNC LINE LOCK Select LINE LOCK to synchronize with the power INTERNAL supply frequency Select INTERNAL for use with internal synchronization automatically selected with DC supply V PHASE 0 358º Adjusts the vertical phase offset when in LINE LOCK mode EXIT Exit the menu Function Selection Description SHUTTER AES AES Auto shutter sets the optimum shutter speed FL for manu...

Страница 13: ...rd menu COAX COM ON OFF If OFF Bilinx communication is disabled DEFAULTS Select next menu Return all set up settings to factory defaults EXIT Exit the menu Function Description SET BACK FOCUS NOW Back focus the lens see Back focus adjustment The scene is focused at maximum lens opening to ensure that the object of interest remains in focus in bright and low light conditions SET LVL When a Video ir...

Страница 14: ...ock the back focus locking button 2 Adjust the lens to the maximum lens opening 3 Turn the back focus adjustment as required 4 Lock the back focus locking button Adjustment procedure Video iris Lens 1 Unlock the back focus locking button 2 Access the Lens Wizard menu 3 The SET BACK FOCUS NOW option is highlighted in the menu 4 Turn the back focus adjustment as required 5 Select the SETLVL option i...

Страница 15: ... 85521 Ottobrunn Germany www bosch sicherheitssysteme de Bosch Security Systems B V P O Box 80002 5600 JB Eindhoven The Netherlands www boschsecuritysystems com 3122 165 22651 03 40 2003 Bosch Security Systems B V Subject to change Printed in Portugal ...