Malfunction
Possible causes
Solution
The unit does
not report an
alarm.
Alarm source is not
selected.
Select possible alarm
sources on the Alarm
sources configuration
page.
No alarm response
specified.
Specify the desired
alarm response on
the Alarm
connections
configuration page; if
necessary change the
IP address.
Control of
cameras or other
units is not
possible.
The cable connection
between the serial
interface and the
connected unit is not
correct.
Check all cable
connections and
ensure all plugs are
properly fitted.
The interface
parameters do not
match those of the
other unit connected.
Make sure that the
settings of all units
involved are
compatible.
The unit is not
operational after
a firmware
upload.
Power failure during
programming by
firmware file.
Have the unit
checked by Customer
Service and replace if
necessary.
Incorrect firmware
file.
Enter the IP address
of the unit followed
by /main.htmin your
Web browser and
repeat the upload.
32
en | Troubleshooting
DINION IP ultra 8000 MP
2015.04 | v2.0 | AM18-Q0688