Browser connection
A computer with Microsoft Internet Explorer is used to receive
live images, control the unit, and replay stored sequences. The
unit is configured over the network using the browser.
Establishing the connection
The unit must have a valid IP address to operate on your
network and a compatible subnet mask. By default, DHCP is pre-
set at the factory to On and so your DHCP server assigns an IP
address. With no DHCP server the default address is
192.168.0.1
1.
Start the Web browser.
2.
Enter the IP address of the unit as the URL.
3.
During initial installation, confirm any security questions
that appear.
Protected network
If a RADIUS server is used for network access control (802.1x
authentication), the unit must be configured first. To configure
the unit, connect it directly to a computer using a network cable
and configure the two parameters, Identity and Password. Only
after these have been configured can communication with the
unit via the network occur.
7.4
7.4.1
7.4.2
32
en | Configuration
DINION IP 7000 HD
2014.09 | v1.0 | AM18-Q0674