background image

Imp

ort

Ap

plia

nce

s.c

om

THE EASIEST WAY TO SELF-IMPORT APPLIANCES DIRECT FROM EUROPE.

Important safety information    

en

3

(

Important safety 

information

Important safety information

:

Warning – Danger of suffocation! 

Packaging material is dangerous to children. 

Never allow children to play with packaging 

material.

:

Warning – Danger of death! 

Risk of poisoning from flue gases that are 

drawn back in.

Always ensure adequate fresh air in the room 

if the appliance is being operated in exhaust 

air mode at the same time as room air-

dependent heat-producing appliance is being 

operated.

Room air-dependent heat-producing 

appliances (e.g. gas, oil, wood or coal-

operated heaters, continuous flow heaters or 

water heaters) obtain combustion air from the 

room in which they are installed and discharge 

the exhaust gases into the open air through an 

exhaust gas system (e.g. a chimney).

In combination with an activated vapour 

extractor hood, room air is extracted from the 

kitchen and neighbouring rooms - a partial 

vacuum is produced if not enough fresh air is 

supplied. Toxic gases from the chimney or the 

extraction shaft are sucked back into the living 

space.

Adequate incoming air must therefore 

always be ensured.

An incoming/exhaust air wall box alone will 

not ensure compliance with the limit.

Safe operation is possible only when the 

partial vacuum in the place where the heat-

producing appliance is installed does not 

exceed 4 Pa (0.04 mbar). This can be 

achieved when the air needed for combustion 

is able to enter through openings that cannot 

be sealed, for example in doors, windows, 

incoming/exhaust air wall boxes or by other 

technical means.

In any case, consult your responsible Master 

Chimney Sweep. He is able to assess the 

house's entire ventilation setup and will 

suggest the suitable ventilation measures to 

you.

Unrestricted operation is possible if the vapour 

extractor hood is operated exclusively in the 

circulating-air mode.

:

Warning – Risk of fire! 

Fatty deposits in the grease filter may catch 

fire. Regularly clean the grease filter. Never 

operate the appliance without a grease 

filter.

Risk of fire! 

Grease deposits in the grease filter may 

catch fire. Never work with naked flames 

close to the appliance (e.g. flambéing). Do 

not install the appliance near a heat-

producing appliance for solid fuel (e.g. 

wood or coal) unless a closed, non-

removable cover is available. There must 

be no flying sparks.

Risk of fire! 

Hot oil and fat can ignite very quickly. Never 

leave hot fat or oil unattended. Never use 

water to put out burning oil or fat. Switch off 

the hotplate. Extinguish flames carefully 

using a lid, fire blanket or something similar. 

Risk of fire! 

When gas burners are in operation without 

any cookware placed on them, they can 

build up a lot of heat. A ventilation 

appliance installed above the cooker may 

become damaged or catch fire. Only 

operate the gas burners with cookware on 

them.

Risk of fire! 

Operating several gas burners at the same 

time gives rise to a great deal of heat. A 

ventilation appliance installed above the 

cooker may become damaged or catch fire. 

Never operate two gas burners 

simultaneously on the highest flame for 

longer than 15 minutes. One large burner of 

more than 5 kW (wok) is equivalent to the 

power of two gas burners.

Содержание DIB97IM50

Страница 1: ...OM EUROPE Thanks for choosing ImportAppliances for your kitchen appliance purchase We hope you are enjoying the convenience quality and affordability of your new appliance If you have any issues or questions please contact us via email info ImportAppliances com User Manual ...

Страница 2: ...com THE EASIEST WAY TO SELF IMPORT APPLIANCES DIRECT FROM EUROPE 3FHJTUFS RXU QHZ GHYLFH RQ 0 RVFK QRZ DQG JHW IUHH EHQHILWV CPTDI IPNF DPN XFMDPNF en Instructions for installation and use Extractor hood Extractor hood ...

Страница 3: ...nce works perfectly at its installation location This appliance is intended for domestic use and the household environment only The appliance is not intended for use outside Do not leave the appliance unattended during operation The manufacturer is not liable for damage which is caused by improper use or incorrect operation This appliance is intended for use up to a maximum height of 2000 metres a...

Страница 4: ... cannot be sealed for example in doors windows incoming exhaust air wall boxes or by other technical means In any case consult your responsible Master Chimney Sweep He is able to assess the house s entire ventilation setup and will suggest the suitable ventilation measures to you Unrestricted operation is possible if the vapour extractor hood is operated exclusively in the circulating air mode War...

Страница 5: ...after sales service Risk of electric shock Do not use any high pressure cleaners or steam cleaners which can result in an electric shock Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Causes of damage Caution Risk of damage due to corros...

Страница 6: ...disposal Dispose of packaging in an environmentally friendly manner ÇOperating modes OperatingmodesExhaust air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heat producing appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the co...

Страница 7: ...isk of burns The appliance becomes hot during operation Allow the appliance to cool down before cleaning Warning Risk of electric shock Penetrating moisture may result in an electric shock Clean the appliance using a damp cloth only Before cleaning pull out the mains plug or switch off the circuit breaker in the fuse box Risk of electric shock Do not use any high pressure cleaners or steam cleaner...

Страница 8: ...he filters with a brush and then rinse them thoroughly Leave the metal grease filters to drain on an absorbent material In the dishwasher Note Slight discolouration may occur if the metal grease filters are cleaned in the dishwasher This discolouration has no effect on the performance of the metal grease filters Use normal domestic dishwashing detergents Do not clean heavily soiled metal grease fi...

Страница 9: ...only be carried out and damaged power cables replaced by one of our trained after sales technicians If the appliance is defective unplug the appliance from the mains or switch off the circuit breaker in the fuse box Contact the after sales service Malfunction table LED lights Defective LED lights may be replaced by the manufacturer their customer service or a qualified technician electrician only ...

Страница 10: ...ned service technicians who carry original spare parts for your appliances Accessories not included in the scope of delivery Note These instructions apply to several appliance models It may be the case that an optional accessory that is listed does not apply for your appliance Note Observe the installation instructions in the accessory E no FD no After sales serviceO GB 0344 892 8979 Calls charged...

Страница 11: ...g to the safety instructions The installer is responsible for ensuring that the appliance works perfectly at its installation location The surfaces of the appliance are easily damaged Avoid damaging them during installation The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of ...

Страница 12: ...air must therefore always be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only when the partial vacuum in the place where the heat producing appliance is installed does not exceed 4 Pa 0 04 mbar This can be achieved when the air needed for combustion is able to enter through openings that cannot be sealed for example in doors w...

Страница 13: ... of death Risk of poisoning from flue gases that are drawn back in The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms that contain heating appliances If the exhaust air is to be conveyed into a non functioning smoke or exhaust gas flue you must obtain the consent of the heating engineer responsible If the ...

Страница 14: ... an all pole isolating switch must be integrated into the permanent electrical installation according to the conditions of overvoltage category III and according to the installation regulations The permanent electrical installation must only be wired by a professional electrician We recommend installing a residual current circuit breaker RCCB in the appliance s power supply circuit 5Installation I...

Страница 15: ... the appliance 1 Hook the appliance from below into the support frame Note Ensure that the mains cable is not trapped 2 Fasten the appliance to the support frame using 2 securing screws 3 Hook in the retaining clip and screw tight Connecting the pipes Note If using an aluminium pipe smooth the connection area beforehand Exhaust air pipe Ø 150 mm recommended size Attach the exhaust air pipe directl...

Страница 16: ... have sharp edges Wear protective gloves 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective foil from both sides 3 Place both parts of the upper flue on the appliance and push together Note The slots of the upper flue must point downwards 4 Push up the upper flue part and secure with 2 screws 5 Insert both lower parts of the flue and push together ...

Страница 17: ...ODF EBUB BU IBOE t BTZ BDDFTT UP PTDI PNF QQMJBODFT 4FSWJDF UHH DQG HDV UHJLVWUDWLRQ DOVR RQ PRELOH SKRQHV XXX CPTDI IPNF DPN XFMDPNF PPLJOH GPS IFMQ PV MM GJOE JU IFSF SHUW DGYLFH IRU RXU RVFK KRPH DSSOLDQFHV QHHG KHOS ZLWK SUREOHPV RU D UHSDLU IURP RVFK H SHUWV LQG RXW HYHU WKLQJ DERXW WKH PDQ ZD V RVFK FDQ VXSSRUW RX XXX CPTDI IPNF DPN TFSWJDF POUBDU EBUB PG BMM DPVOUSJFT BSF MJTUFE JO UIF BUUB...