Bosch DHL895CAU Скачать руководство пользователя страница 6

6

Operating the appliance

These instructions apply to several appliance variants. It is 

possible that individual features are described which do not 

apply to your appliance.

Note: 

Switch on the extractor hood when you start cooking and 

switch it off again several minutes after you have finished 

cooking. This is the most effective way of removing the kitchen 

fumes.

Control panel

Setting the fan

Switching on

Press the 

#

, 2/

y

, 3/

H

 or 

à

 button.

Switching off

Press the 

#

 button.

Note: 

If fan level 2 or 3 is switched on, press the 

#

 button 

twice.

Intensive setting

You can use the intensive setting if there is a large build-up of 

odours and fumes/vapours.
Press the 

à

 button.

Intensive mode is activated.

Notes

The intensive mode run time is limited to 6 minutes.

Once 6 minutes has elapsed, the appliance switches back to 

the fan level that was previously selected.

Intensive mode can be activated when the appliance is 

switched off; once 6 minutes has elapsed, the appliance 

switches itself off again.

Fan run-on

With the fan run-on, the appliance continues to run at the level 

that was previously set and switches off automatically after 

30 minutes.

1.

Set the fan level.

2.

Press and hold the 2/

y

 button.

Fan run-on is activated. The button for this level flashes green.

Interval ventilation

With interval ventilation, the ventilation system switches on 

automatically at the lowest level for 10 minutes every hour. The 

interval ventilation switches off after 24 hours.

Switching on

Press and hold the 3/

H

 button.

The interval ventilation is activated. The 

#

 button flashes.

Switching off

Press and hold the 3/

H

 button or press the 

#

 button.

Lighting

The lighting can be switched on and off independently of the 

ventilation system.
Press the 

B

 button.

The lighting is switched on.

Setting the brightness

Press and hold the 

B

 button until the desired brightness is 

reached.

Saturation indicator

If F is lit, this means that the integrated filters are saturated:
Lit permanently: clean the metal grease filter
For instructions on how to clean metal grease filters, refer to the 

section 

Cleaning and maintenance

.

Resetting the saturation indicator

1.

Switch off the appliance.

2.

Press and hold the 

#

 button for 3 seconds.

The saturation indicator is reset. F goes out.

Explanation

B

Light on/off

#

Fan off/fan level 1

2/

y

Fan level 2/fan run-on

3/

H

Fan level 3/interval ventilation

à

Intensive mode

F

Saturation indicator

)

Содержание DHL895CAU

Страница 1: ... en Instruction manual Extractor hood DHL895CAU ...

Страница 2: ......

Страница 3: ...e sea level This appliance may be used by children over the age of 8 years old and by persons with reduced physical sensory or mental capabilities or by persons with a lack of experience or knowledge if they are supervised or are instructed by a person responsible for their safety how to use the appliance safely and have understood the associated hazards Children must not play with on or around th...

Страница 4: ...uickly Never leave hot fat or oil unattended Never use water to put out burning oil or fat Switch off the hotplate Extinguish flames carefully using a lid fire blanket or something similar Risk of fire When gas burners are in operation without any cookware placed on them they can build up a lot of heat A ventilation appliance installed above the cooker may become damaged or catch fire Only operate...

Страница 5: ...g if you no longer require it Clean and if required replace the filter at regular intervals in order to increase the effectiveness of the ventilation system and to prevent the risk of fire Environmentally friendly disposal Dispose of packaging in an environmentally friendly manner Operating modes This appliance can be used in exhaust air mode or circulating air mode Exhaust air mode Note The exhau...

Страница 6: ...nd switches off automatically after 30 minutes 1 Set the fan level 2 Press and hold the 2 y button Fan run on is activated The button for this level flashes green Interval ventilation With interval ventilation the ventilation system switches on automatically at the lowest level for 10 minutes every hour The interval ventilation switches off after 24 hours Switching on Press and hold the 3 H button...

Страница 7: ...metal mesh grease filters These instructions apply to several appliance variants It is possible that individual features are described which do not apply to your appliance Risk of fire Grease deposits in the grease filter may catch fire Clean the grease filter at least every 2 months Never operate the appliance without the grease filter Notes Do not use any aggressive acidic or alkaline cleaning a...

Страница 8: ...ient odour filtration the filter must be serviced regularly The activated charcoal filters must be replaced at least every 4 months Notes The activated charcoal filters are not included in the delivery The activated charcoal filters can be obtained from specialist retailers from our after sales service or from the Online Shop The activated charcoal filters cannot be cleaned or reactivated 1 Remove...

Страница 9: ...ate with these numbers can be found inside the appliance remove the metal mesh grease filter to gain access You can make a note of the numbers of your appliance and the telephone number of the after sales service in the space below to save time should it be required Please be aware that a visit by an after sales engineer will be charged if a problem turns out to be the result of operator error eve...

Страница 10: ......

Страница 11: ......

Страница 12: ...970120 9001018774 9001018774 Robert Bosch Hausgeräte GmbH Carl Wery Straße 34 81739 München Germany www bosch home com ...

Отзывы: