background image

Note: 

The extractor hood housing inside

the wall cupboard can be boarded up (e.g.
with chipboard).

Please observe the following:

– The shelf must not be rest upon the

extractor hood housing.

– The board at the front should not be

attached to the housing.

– Ensure that access is possible for

replacing filters or by Customer Service. 

Electrical connection

WARNING: THIS APPLIANCE MUST BE
EARTHED
IMPORTANT: Fitting a Different Plug:

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

– Earth

Blue

– Neutral

Brown

– Live

If you fit your own plug, the colours of
these wires may not correspond with the
identifying marks on the plug terminals.
This is what you have to do:

1.

Connect the green and yellow (Earth)
wire to the terminal in the plug marked
‘E’ or with the symbol (        ), or 
coloured green or green and yellow.

2.

Connect the blue (Neutral) wire to the
terminal in the plug marked ‘N’ or 
coloured black.

3.

Connect the brown (Live) wire to the 
terminal marked ‘L’, or coloured red.

The extractor hood 

may only be 

connected to an earthed socket that has
been installed according to the relevant
regulations. If possible, site the earthed
socket directly above the wall cupboard or
in its immediate vicinity.

Electrical specifications:

Are to be found on the name plate inside
the appliance after removal of the filter
frame.

Before undertaking any repairs,

always disconnect the extractor hood from
the electricity supply.

Length of the connecting cable: 1,30 m.

If it is necessary to wire the extractor
hood directly into the mains:

The extractor hood may only be connected
up by a qualified electrician approved by
the appropriate electricity company.

A separator must be installed in the 
household circuit. A suitable separator is a
switch that has a contact gap of more than
3 mm and interrupts all poles. Such 
devices include circuit breakers and
contactors.

This extractor hood complies with EC 
regulations relating to the suppression of
RF interference.

Weight in kg:

Exhaust air

Re-circulating air

7,0

8,0

The manufacturer reserves the right to make design
alterations in the interests of technical development.

Installation inside the wall 
cupboard

15

Содержание DHI 625 M AU

Страница 1: ...a Operating and installation instructions DHI 625 M AU Internet http www bosch hausgeraete de Bosch Info Team de Tel 01 80 5 30 40 50 E 0 12 Min DTAG ...

Страница 2: ...2 Abb 1 ELECTR Fig 1 GAZ min 650 min 430 ...

Страница 3: ...c If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration This rule does not apply to the use of c...

Страница 4: ...taneously Before using your appliance for the first time please read these Instructions for Use carefully They contain important information concerning your personal safety as well as on use and care of the appliance Please retain the operating and installation instructions for a subsequent owner Do not use the appliance if damaged The appliance is not intended for use by young children or infirme...

Страница 5: ...in cooking Switch the ventilator OFF a few minutes after you have finished cooking Switching the ventilator ON 1 Pull out the vapour extractor tray The ventilator is operating 2 Select the required ventilator power level Operating controls on different models How to operate the extractor hood Light Note The light can be switched on at any time including when the vapour extractor tray has been push...

Страница 6: ...extractor hood performs as effectively as possible Removing inserting the fleece filter 1 Remove the wire frame 2 Exchange the fleece filter 3 Refit the wire frame Metal grease filter The filter mat is made of non combustible metal Caution As it becomes more and more saturated with grease the filter also becomes increasingly inflammable The efficiency of the extractor hood can also be adversely af...

Страница 7: ...oving the filter 1 Remove the filter frame see details on previous page 2 Place wing nut and sleeve over screw insert into housing and tighten firmly applies only when installing filter for first time Screw sleeve and wing nut are en closed with the activated carbon filter 3 Hook the activated carbon filter into the left hand side of the extractor hood housing push the other side upwards and secur...

Страница 8: ...ble Use a hot detergent solution or a mild window cleaner to clean the canopy of the extractor hood Do not scrape off any dirt that has dried on but loosen it up with a damp cloth Do not use abrasive cleaning agents or sponges that could cause scratches Note Do not use alcohol spirit on pla stic parts otherwise the surface may become matt in appearance Caution Ensure that the kitchen is ade quatel...

Страница 9: ...liance render it unusable You received your new appliance in a protective shipping carton All packaging materials are environmentally friendly and recyclable Please contribute to a better environment by disposing of packaging materials in an environmentally friendly manner Please ask your dealer or inquire at your local authority about current means of disposal The extractor hood can be used in ex...

Страница 10: ...e achieved if the combustion air is able to flow through non lockable openings e g in doors windows and in conjunction with an air supply air intake wall box or by other technical procedures such as reciprocal interlocking If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarante...

Страница 11: ...of fresh air Exhaust outlet connection Pipe diameter 100 or 120 mm Insert the enclosed outlet connector and twist it as far as it will go If the pipe diameter is 120 mm cut out the inner part of the outlet connector Exhaust air flows upwards Cut a hole in the top of the wall cupbo ard including a groove for the mains cable Template O I lis enclosed The complete installation set can be obtained fro...

Страница 12: ... a gimlet Details for drilling l 2 mm max 10 mm deep Use enclosed template O II for marking points where hood is to be mounted Caution The mounting points shown on the template have been configured in such a way as to allow a 20 mm thick handle to be attached flush with the front edges of the cupboard If no handle is going to be attached the mounting points must be brought forward by 20 mm If the ...

Страница 13: ...d on the 4 mounting brackets 3 Loosely screw in the 4 enclosed screws Align the extractor hood and then tighten screws Check that the extractor hood is firmly fitted into the cupboard 20 20 mind 15 mind 475 If the shelf is permanently fixed inside the cupboard 4 holes must be drilled to provide access to the 4 mounting screws for the extractor hood 5 Route the mains cable through the hole in the w...

Страница 14: ...ng a handle to the vapour extractor A handle can be attached to the vapour extractor This handle can either be a wooden strip that matches the kitchen cupboards or a the handle that is available as an optional accessory see section on optional accessories in the user instructions 1 Use the enclosed template O III to mark the 3 mounting points on the handle and start the hole with a gimlet Details ...

Страница 15: ...oloured red The extractor hood may only be connected to an earthed socket that has been installed according to the relevant regulations If possible site the earthed socket directly above the wall cupboard or in its immediate vicinity Electrical specifications Are to be found on the name plate inside the appliance after removal of the filter frame Before undertaking any repairs always disconnect th...

Страница 16: ...9000 021 954 Printed in Germany 0804 Es Robert Bosch Hausgeräte GmbH DHZ 2100 DHZ 3200 299600 084848 DHZ 3350 DHZ 3105 4 5 6 1 1 2 3 2 3 3x ...

Отзывы: