D7212G Operation and Installation Guide

D7212G

Page 21

© 2003 Bosch Security Systems

4998138544C

Installation

3.0

Installation

3.1

Before Beginning

This section contains a general installation procedure and provides references to other sections of the guide for detailed
instructions.

Bosch Security Systems recommends a review of this guide and the D7212G Program Entry Guide (P/N: 4998138538) before
beginning the installation to determine the hardware and wiring requirements for the features that will be used.

Have the following additional documents available when reading through this guide:

• D7212G Program Record Sheet (P/N: 4998138542)

• Security System Owner’s Manual (P/N: 71-06633-000)

• Command Center Installation Manual (D1255, D1256, D1257, D1260, or D720)

Before beginning the installation, become familiar with the operation of the D5200 Programmer or the Remote Account
Manager (RAM IV).

3.2

Enclosure Options

Mount the control/communicator assembly in any of the Bosch Security Systems enclosures listed below. Refer to the
D7212G Approved Applications Compliance Guide (P/N: 4998138560) to determine if the application requires a specific
enclosure.

• D8103 Universal Enclosure (tan)

• D8109 Fire Enclosure (red)

• D8108A Attack Resistant Enclosure (tan)

3.3

Beginning the Installation

1.

Mount the enclosure in the desired location. Use all five mounting holes. See Figure 2.

POINT CHART LABEL

MOUNTING

SKIRT HOOK

MODULE MOUNTING

LOCATIONS

MODULE

MOUNTING

LOCATIONS

TAMPER SWITCH

MOUNTING LOCATION

MOUNTING

SKIRT HOOK

SKIRT MOUNTING HOLE

MOUNTING

SKIRT HOOK

OPENINGS

LOCK DOWN TAB

BACK OF

D7212G

Figure 2: Enclosure Mounting

2.

Run the necessary wiring throughout the premises, and pull the wires into the enclosure.

Note:

EMI (Electro Magnetic Interference) may cause problems. Refer to 

EMI on Long Wire Runs

 in the

 D9412G/D7412G/

D7212G Installation and Troubleshooting Quick Reference Guide

 (P/N: 43700).

Содержание D7212G

Страница 1: ...Control Communicator D7212G Operation and Installation Guide ...

Страница 2: ...D7212G Operation and Installation Guide Page 2 2003 Bosch Security Systems 4998138544C D7212G Operation and Installation Guide ...

Страница 3: ...d Centers 18 2 4 5 Keyswitch 18 2 4 5 Event Memory 18 2 4 7 Event Log 18 2 4 8 EMI Lightning Transient Protection 18 2 4 9 Programming 18 2 4 10 Other Features 19 2 4 11 Control Communicator Assembly 19 2 4 12 Components and Literature Available by Separate Order 19 2 4 13 Listings and Approvals 20 3 0 Installation 21 3 1 Before Beginning 21 3 2 Enclosure Options 21 3 3 Beginning the Installation ...

Страница 4: ...tinuous Current Draw 29 5 4 Programmable Power Outputs Terminals 29 5 4 1 Programming 29 5 4 2 Optional Relays Required 30 5 4 3 Terminals 6 and 7 30 5 4 4 Fire System Power Formula 30 5 4 5 Terminal 8 30 6 0 Telephone Connections 31 6 1 Registration 31 6 2 Notification 31 6 3 Location 31 6 4 Phone Cord Connection 31 6 5 Phone LED Red 31 6 6 Operation Monitor LED Green 32 6 7 Dialing Format 32 6 8...

Страница 5: ...ITs 43 8 4 5 Line Termination 43 8 4 6 OctoPOPIT Sensor Loops 44 8 4 7 Address Assignment Switches 44 8 5 Testing Off board Points 44 9 0 Off board Relays 47 9 1 D8129 OctoRelay 47 9 1 1 Configuring the D8129 OctoRelay 47 9 1 2 Relay Outputs 47 9 1 3 Installation 47 9 1 4 Wiring Connections 47 10 0 Arming Devices 49 10 1 Description 49 10 2 Command Center Terminals 49 10 2 1 Assigning the command ...

Страница 6: ...erface Module 55 11 5 3 Address Settings 55 11 5 4 Supervision 55 12 0 Programmer and Accessory Connections 57 12 1 Programmer Connector 57 12 1 1 Programmer Access Reports 57 12 2 Accessory Connector 57 13 0 Faceplate 59 13 1 D7212G Faceplate 59 Appendix A System Wiring Diagrams Issue A 61 A 1 D7212G Control Communicator 1 of 3 61 A 2 D7212G Control Communicator 2 of 3 62 A 3 D7212G Control Commu...

Страница 7: ...e 10 Phone Monitor Select 33 Figure 11 On board Point Sensor Loop Wiring 35 Figure 12 Wiring for Installations using the Ademco AB 12 Bell Housing 36 Figure 13 Connecting the D8125 POPEX to the D7212G Panel 40 Figure 14 Program Record Sheet 41 Figure 15 Connecting D8128D OctoPOPITs to the D7212G 45 Figure 16 D8129 Connections to the D7212G 48 Figure 17 Power at Command Centers 50 Figure 18 Keyswit...

Страница 8: ...Compatible Command Centers 18 Table 6 Listings 20 Table 7 Battery Discharge Recharge Schedule 27 Table 8 Charging Status and Low Battery LEDs 28 Table 9 Data Expansion Loop Wire Specifications 39 Table 10 D8128D OctoPOPIT Switch Settings for D7212G 44 Table 11 D8129 OctoRelay Switch Settings 47 Table 12 Command Cneter Address Settings 49 Table 13 Command Center Connections 50 Table 14 SDI Device C...

Страница 9: ...er Supply provides information on the primary and secondary modules and instructions on connecting and programming them 5 Power Outputs provides information on the power outputs and instructions on installing the transformer explains the status and battery LEDs 6 Telephone Connections provides information on connecting the phone line and programming it for use 7 On Board Points provides informatio...

Страница 10: ... Installation Guide 36796 D9412G D7412G D7212G Installation and Troubleshooting Quick Reference Guide 43700 RAM IV Operations Manual 38849 Security System Owner s Manual 71 06633 000 Security System Owner s Manual Supplement 33267 7000 9000 Series Point Chart Label 79 06660 000 9000 9000G Series Technogram UL Certificated Bank Safe and Vault Applications 73 07302 000 9000 9000G Series Technogram S...

Страница 11: ...J38X or RJ31X jack The ringer equivalence number REN is used to determine the number of devices that may be connected to the telephone line Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call In most but not all areas the sum of the RENs should not exceed five 5 To be certain of the number of devices that may be connected to the line as determ...

Страница 12: ...D7212G Operation and Installation Guide Page 12 2003 Bosch Security Systems 4998138544C D7212G Introduction Notes ...

Страница 13: ...es alarm and auxilliary relay output Other functions available D8125 or D8125MUX Interface used for point expansion Each D8128D OctoPOPIT combines eight POPIT points in one module D8132 Modules two 12 VDC 7Ah batteries provide additional power for command centers and other powered devices Figure 1 System Configuration 2 1 9000G Series Panel Differences Table 3 provides an overview of the differenc...

Страница 14: ...s supplied at Terminals 3 and 32 and at the Programming Connector Alarm Power Output 2 0 A maximum at 10 2 VDC to 13 9 VDC output Output may be steady or one of three pulsed patterns depending on programming See Relays in the D7212G Program Entry Guide P N 4998138538 Switched Aux Power 1 4 A maximum at 10 2 VDC to 13 9 VDC output Continuous output is interrupted by Sensor Reset or alarm verificati...

Страница 15: ...elay resets battery charging begins Battery Trouble and AC Restoral reports sent Battery Restoral report sent Low Battery LED off Charging Status LED off battery float charged Environmental Temperature Relative Humidity 32 F to 122 F 0 C to 50 C 5 to 85 86 F 30 C non condensing Arming Stations D1255 Command Center D1256 Fire Command Center D1257 Fire Alarm Annunciator D1260 Alpha V Command Center ...

Страница 16: ... Center white ZX776Z PIR Motion Sensor 50 ft with POPIT D1218 12 V 17 2 Ah Rechargeable Battery ZX794Z PIR Motion Sensor 80 ft with POPIT D1255 Command Center General Purpose ZX835 PIR Microwave Motion Sensor 35 ft D1255R Command Center red Z938Z PIR Motion Sensor 60 ft with POPIT D1255W Command Center white ZX970 PIR Microwave Motion Sensor 70 ft with POPIT The D8125INV has not been investigated ...

Страница 17: ...g D8128D OctoPOPITs D8125 POPEX Modules and D9127 D8127 POPITs MUX devices may also be used with the D8125MUX or wireless transmitters with the D8125INV 2 4 2 Areas and Accounts The system supports up to four separate areas All points can be assigned to a single area or spread out over up to four areas The panel is armed and disarmed by area and several areas can be armed and disarmed with one men...

Страница 18: ...rols 2 4 5 Event Memory The system uses event memory to store events for each area The events for an area can be viewed at a D1255 or D1260 Command Center assigned to the area The panel clears the events for an area from event memory and starts storing new events when the area is master armed 2 4 7 Event Log The system stores from 500 to 1000 events and event modifiers from all areas in its event ...

Страница 19: ...7212G Control Communicator is shipped pre assembled from the factory with the following parts Literature Pack D7212G Approved Applications Compliance Guide P N 4998138560 D7212G Operation and Installation Guide P N 4998138544 D7212G Program Entry Guide P N 4998138538 D7212G Program Record Sheet P N 4998138542 D7212GReleaseNotes P N 4998138543 D9412G D7412G D7212G Installation and Troubleshooting Q...

Страница 20: ...2G Literature Pack includes the D7212G Approved Applications Compliance Guide P N 4998138560 Refer to this guide for additional guidelines for installing the control communicator in UL and Fire specific applications Fire UL Underwriters Laboratories lists the D7212G Control Communicator as a Control Unit for Household Fire Warning CSFM Approval by the California State Fire Marshall for Household F...

Страница 21: ... Programmer or the Remote Account Manager RAM IV 3 2 Enclosure Options Mount the control communicator assembly in any of the Bosch Security Systems enclosures listed below Refer to the D7212G Approved Applications Compliance Guide P N 4998138560 to determine if the application requires a specific enclosure D8103 Universal Enclosure tan D8109 Fire Enclosure red D8108A Attack Resistant Enclosure tan...

Страница 22: ... detect ground fault conditions If a ground fault condition occurs the command centers will display SERVC GND FAULT and the panel will transmit a TROUBLE REPORT GROUND FAULT AREA Modem IIIa2 format only In order for the panel to detect a ground fault condition the panel must see the ground fault for at least 30 consecutive seconds When the panel recognizes that ground fault condition is corrected ...

Страница 23: ...be carried is being discharged to the panel The panel may generate WATCHDOG RESET and or PARAM FAIL events See the Watchdog Reset Reports section in the D9412G D7412G D7212G Installation and Troubleshooting Quick Reference Guide P N 43700 for a description of these events Always touch Terminal 10 the panel s earth ground connection before beginning work on the panel 3 6 2 Install and Wire Detectio...

Страница 24: ...e receiver if programmed for reporting 3 8 Install the Point Chart Label Bosch Security Systems recommends the 7000 9000 Series Point Chart Label P N 79 06660 000 provided in the literature pack be filled out and installed on the inside of the enclosure door for all systems Point chart label required for fire systems with verification points The point chart label must be installed for fire or comb...

Страница 25: ...s 50 ft 15 m AC wiring can induce both noise and low level voltage into adjacent wiring Route phone and sensor loop wiring away from any AC conductors including the transformer wire Route data wiring away from AC and phone wiring Connect the battery and then plug in the transformer Bosch Security Systems recommends that the battery always be connected first and then the transformer be plugged in S...

Страница 26: ...ARM SW AUX 7 8 GROUND FAULT DETECT Enabled Disabled PHONE LED RED ON WHEN COMMUNICATING OFF WHEN IDLE LOOP START GND START GROUND START 12 11 13 Point 1 Point 2 GROUND START Requires Relay D136 in Ground Start Socket Battery Wires To Batteries To ensure proper spacing secure wires using Tie Wraps or similar devices Battery terminals and wires are not power limited Standby Battery Figure 5 Non Powe...

Страница 27: ...Charging Status LED will illuminate Loss of AC Load Shed Relay protects battery During an AC power loss the battery supplies all power to the security system If the battery voltage falls below 10 2 V during an AC power loss a load shed relay isolates the battery from the panel and disables the panel Load shed protects the battery from being damaged by deep discharge When AC power restores the load...

Страница 28: ...r bells draw more than 1 4 A If the LED comes on regularly for extended periods or doesn t go out check the current draw for devices connected to the power outputs See Section 5 0 Power Outputs on page 29 for instructions Yellow Flash once min System is checking the battery Charging Status LED Yellow and Red Flash once min When the current draw for devices connected to the power outputs exceeds 1 ...

Страница 29: ...uous current draw for powered devices connected to Terminals 3 8 and 32 must not exceed 1 4 A Devices powered from these outputs must operate over a range of 10 2 VDC to 13 9 VDC Power restricted for fire and combined fire burglary systems Use the Fire System Power Formula to calculate the current available for fire and combined fire burglary system see Section 5 4 Programmable Power Outputs Termi...

Страница 30: ...etermining alarm power Use the Fire System Power Formula below to calculate the current available for fire and combined fire burglary systems 5 4 4 Fire System Power Formula To calculate the current available at Terminals 6 and 7 for fire and combined fire burglary systems 1 Add together the current draws for all devices connected to Terminals 3 8 and 32 This total is the total current required fo...

Страница 31: ...ation To prevent jamming of signals wire the RJ31X or RJ38X jack before the in house phone system to support line seizure See Figure 8 Install the jack on the street side of the phone switch wired ahead of any PBX equipment Line seizure provides for a temporary interruption of normal phone usage while the communicator transmits data After installation confirm that the panel seizes the line acquire...

Страница 32: ...tage levels to test the status of the phone line In some instances a given telephone line may be out of service without affecting the voltage on the line The phone line monitor can not recognize this trouble condition 6 9 Called Party Disconnect Telephone companies provide called party disconnect to allow the called party to terminate a call The called party must go on hook hang up for a fixed int...

Страница 33: ...ay socket is in the lower left corner as shown in Figure 7 on page 30 The plug in relay is shorter than the socket it plugs into It can be installed in either the left or right end of the socket Don t rely on relay labeling Don t rely on the labelling to install D136 relays Check for the side with three pins The three pins go on the top side on the socket Incorrect insertion does not damage the re...

Страница 34: ...D7212G Operation and Installation Guide Page 34 2003 Bosch Security Systems 4998138544C D7212G Telephone Connections Notes ...

Страница 35: ...to 8 can be determined by measuring the voltage across the point input terminal and one of the common terminals The sensor loops must be connected and the 1 kΩ end of line resistor in place Open Loop Greater than 3 7 VDC but less than 5 0 VDC Normal Loop Greater than 2 0 VDC but less than 3 0 VDC Shorted Loop Greater than 0 0 VDC but less than 1 3 VDC 7 4 Point Response Time The panel scans both o...

Страница 36: ...ator is UL Listed For Household Fire Alarm and Central Station Local Police Station Connect and Household Burglar Alarm System is Intended To Be Checked By A Qualified Technician At Least Every 3 Years The types of initiating circuits the panel has been approved for are A M W SS VOLTAGE RANGES Open 3 7 5 0 VDC Normal 2 0 3 0 VDC Short 0 0 1 3 VDC GRN Reset Pin Disable All Except Battery Charging A...

Страница 37: ...enerated the system is presently in a Service Walk Test and the point input goes from an electrically normal state to an open or shorted state the command center will neither annunciate nor display a trouble condition However an EXTRA POINT event will be logged and printed to an on site printer if programmed Note The Service Walk Test will never display a points electrical state as Extra If the po...

Страница 38: ...D9112 Save this set for use with the D7212G It will be used later to label the POPITs 8 3 1 Mounting Use the following procedure to install the D8125 in the enclosure with the panel 1 Align the D8125 POPEX Module with any of the four mounting locations in the enclosure See Figure 2 on page 21 2 Use the screws provided with the module to secure it in the enclosure 8 3 2 Wiring the D8125 to the Cont...

Страница 39: ...p terminals on each POPEX Module Follow the procedure below to connect the data expansion loops to the D8125 POPEX Module see Figure 13 on page 40 Remember a maximum of 32 POPITs can be connected to one D8125 on the D7212G 1 Connect the positive Data terminal from the first POPIT on the data expansion loop to one of the D8125 Module s positive terminals 2 Connect the negative Data terminal from th...

Страница 40: ...D7212G Operation and Installation Guide Page 40 2003 Bosch Security Systems 4998138544C D7212G Off board Points Figure 13 Connecting the D8125 POPEX to the D7212G Panel ...

Страница 41: ...98138538 Eighth column Custom Point Text the text displayed at command centers for the point The text is transmitted to the receiver when the panel is using the Modem IIIa2 format D7212G Default values are shown in or in bold RADXPNTS Handler Point Assignments 001 through 040 POPIT Switch Setting Trans lation Point Point Index Area Assign Debounce BFSK Relay Custom Point Text 100 001 __ __ 1 ____ ...

Страница 42: ...PIT and D8125 POPEX modules in parallel to the ZONEX Bus terminals on the same panel Review Section 5 0 Power Outputs on page 29 to be sure to provide enough power for the OctoPOPITs and other powered devices that will be connected to the system 8 4 2 Listing The D8128D OctoPOPIT Module is UL Listed for Local or Police Connected Burglary Alarm Central Station Burglary Alarm and Household Burglary ...

Страница 43: ...er never assign the same point number to more than one point 1 Power down first Power down the panel by disconnecting the positive red battery lead at the battery and unplugging the transformer 2 Connect Terminal 1 on the OctoPOPIT to Terminal 9 on the D7212G 3 Connect Terminal 2 on the OctoPOPIT to Terminal 28 on the panel if assigning point numbers from 9 to 40 to this OctoPOPIT See Section 8 4 ...

Страница 44: ...nd of line resistor Attach a resistor even if you don t enable the loop The OctoPOPIT comes with a D105BL resistor for each sensor loop Take care not to duplicate point assignments Points assigned to both an OctoPOPIT sensor loop and a POPIT two OctoPOPIT sensor loops or two POPITs do not function properly 8 4 7 Address Assignment Switches Switches 1 2 3 and 4 assign the OctoPOPIT sensor loops to ...

Страница 45: ... RELAY A RELAY B RELAY C AUX PO 1 2 3 4 5 6 7 8 9 10 CLASS 2 TRANS 16 5 VAC 40 VAC Model D1640 Internally Fuse Requires Unsw Do Not Share Low Battery RED PR AL Re GROUND FAUL Pin Battery amming E CONNECTIONS POWER DATA BUS A DATA BUS B COMMON ZONEX OUT 1 ZONEX IN 1 32 31 30 29 28 27 PROG CONN Refer to Section 8 4 7 Address Assignment Switches on page 44 for information on how these switch settings...

Страница 46: ...D7212G Operation and Installation Guide Page 46 2003 Bosch Security Systems 4998138544C D7212G Off board Points Notes ...

Страница 47: ...ivate while you are setting the OctoRelay switches or programming the panel You may wish todisconnectequipmentconnectedtorelayoutputsbeforeperformingthesefunctions 9 1 2 Relay Outputs Each OctoRelay output provides a Form C dry contact rated for 1 0 A at 12 VDC Normally open common and normally closed terminals are available for each relay output When an individual output is activated there is con...

Страница 48: ...EARTH GRO COMMON BATTERY N Maximum Charging Current 1 4 Amps BATTERY POSITIVE ONLY RELAY A RELAY B RELAY C AUX PO 1 2 3 4 5 6 7 8 9 10 CLASS 2 TRANS 16 5 VAC 40 VAC Model D1640 Internally Fuse Requires Unsw Do Not Share Low Battery RED PR AL Re GROUND FAUL Pin Battery amming E CONNECTIONS POWER DATA BUS A DATA BUS B COMMON ZONEX OUT 1 ZONEX IN 1 32 31 30 29 28 27 PROG CONN Figure 16 D8129 Connecti...

Страница 49: ... Guide P N 4998138538 for complete programming details on command center options There are five types of command centers available for use with the system D1255 16 character alphanumeric display for general use D1256 text display command center with functional keys optimized for local fire alarm control D1257 text display command center for fire annunciation D1260 Easy to read 4 line by 20 charact...

Страница 50: ... 1000 ft 305 m per run Extra power needed for more command centers The D1255 Command Center draws 104 mA when it is idle It draws 206 mA with the keys lit and the sounder activated Review Section 5 0 Power Outputs on page 29 to determine the total power output requirements for the system One or more D8132 Battery Charger Power Supply Modules may need to be added for the number of command centers t...

Страница 51: ...stor for the point at the keyswitch so that the switch shorts the resistor when it operates An open on the circuit produces an alarm if the area is armed and a trouble if it is disarmed See Figure 18 10 4 4 Keyswitch Operation Maintained Contact If the point to which the keyswitch is connected is programmed for a maintained contact an open on the arming circuit arms the area All faulted points are...

Страница 52: ...D7212G Operation and Installation Guide Page 52 2003 Bosch Security Systems 4998138544C D7212G Arming Devices Notes ...

Страница 53: ...Printer Interface Module is a 4 wire powered device used to connect a standard parallel printer to a panel The D7212G can supervise one printer Each printer requires a separate D9131A Parallel Printer Interface Module The D9131A connects to the printer using a standard parallel printer cable 11 3 1 Switch Settings Switches on the D9131A assign the address to the printer The address determines if t...

Страница 54: ...o communicate with the D9133 and SERVC SDI 80 displays at the command center The report to the receiver includes the address of the troubled module to indicate which module needs service 11 5 SDI Address 88 SDI Address 88 is available with the D7212G Panel and is used for several different applications When using SDI Address 88 only one of the listed devices may be connected at a time 11 5 1 D9133...

Страница 55: ...talled up to 1000 ft 305 m away from the panel using 18 AWG wire 11 5 3 Address Settings D9133TTL E Network Interface Module A jumper must be placed over Pin 8 for the D9133TTL E SDI Address 88 to be used for RAM IV and or enhanced communications in a LAN WAN environment 1 2 3 4 88 11 5 4 Supervision Supervision of the D9133DC and D9133TTL E at SDI Address 88 is available through programming that ...

Страница 56: ...D7212G Operation and Installation Guide Page 56 2003 Bosch Security Systems 4998138544C D7212G SDI Devices Notes ...

Страница 57: ...unction send or receive program 4 Disconnect the programmer Reset Pin Disable All Except Battery Charging And Programming PERIPHERAL DEVICE CONNECTIONS RED POWER YELLOW DATA BUS A GREEN DATA BUS B BLACK COMMON 32 31 30 29 RESET PIN LOCKED CLOSED RESET PIN NORMAL OPEN FOR NORMAL PANEL OPERATION Figure 19 Reset Pin 12 1 1 Programmer Access Reports When a program is sent to the panel the panel sends ...

Страница 58: ...ity Systems 4998138544C D7212G Programmer and Accessory Connections Accessory Connector Programming Connector GRN PROG CONN Point 8 GND FAULT Detect L E D I S A B L E DATA BUS B COMMON ZONEX OUT 1 ZONEX IN 1 30 29 28 27 Figure 20 Programmer and Accessory Connections ...

Страница 59: ...D7212G Operation and Installation Guide D7212G Page 59 2003 Bosch Security Systems 4998138544C Faceplate 13 0 Faceplate 13 1 D7212G Faceplate Figure 21 D7212G Faceplate ...

Страница 60: ...D7212G Operation and Installation Guide Page 60 2003 Bosch Security Systems 4998138544C D7212G Faceplate Notes ...

Страница 61: ...on Guide D7212G Page 61 2003 Bosch Security Systems 4998138544C Appendix A System Wiring Diagrams Issue A Appendix A System Wiring Diagrams Issue A A 1 D7212G Control Communicator 1 of 3 Figure 22a D7212G System Wiring Diagram 1 of 3 ...

Страница 62: ...ration and Installation Guide Page 62 2003 Bosch Security Systems 4998138544C D7212G Appendix A System Wiring Diagrams Issue A A 2 D7212G Control Communicator 2 of 3 Figure 22b D7212G System Wiring Diagram 2 of 3 ...

Страница 63: ...ration and Installation Guide D7212G Page 63 2003 Bosch Security Systems 4998138544C Appendix A System Wiring Diagrams Issue A A 3 D7212G Control Communicator 3 of 3 Figure 22c D7212G System Wiring Diagram 3 of 3 ...

Страница 64: ...D7212G Operation and Installation Guide Page 64 2003 Bosch Security Systems 4998138544C D7212G Appendix A System Wiring Diagrams Issue A Notes ...

Страница 65: ...ints 9 to 40 D8127 POPITs have dipswitches 1 to 6 whereas D9127 POPITs have dipswitches 0 to 6 Switch Address 0 1 2 3 4 5 6 009 0 1 2 3 4 5 6 010 0 1 2 3 4 5 011 0 1 2 3 4 6 012 0 1 2 3 4 013 0 1 2 3 5 6 014 0 1 2 3 5 015 0 1 1 3 6 016 0 1 2 3 017 0 1 2 4 5 6 018 0 1 2 4 5 019 0 1 2 4 6 020 0 1 2 4 021 0 1 2 5 6 022 0 1 2 5 023 0 1 2 6 024 0 1 2 025 0 1 3 4 5 6 026 0 1 3 4 5 027 0 1 3 4 6 028 0 1 ...

Страница 66: ...D7212G Operation and Installation Guide Page 66 2003 Bosch Security Systems 4998138544C D7212G Appendix B Point Address Chart Notes ...

Страница 67: ... POPEX Connecting to the D7212G 40 Installing 38 D8125 POPIT Modules 38 D8127 POPIT Modules 38 D8128D OctoPOPIT 42 Connecting to the D7212G 45 D8129 OctoRelay 47 D9127 POPIT Modules 38 D9412G D7412G D7212G Differences Between 13 Debounce Count 35 Documentation Conventions 10 E Earth Ground 16 22 25 Connecting 22 EMI Lightning Transient Protection 18 Enclosure Options 21 Transformer 25 EOL Resistor...

Страница 68: ...mmable Power Outputs Terminals 29 Switched Auxiliary 29 Total Available Power 29 Power Supply 25 Primary Power Terminals 25 Printer 53 Programmer 24 Connecting 57 Programmer Connector 57 Programming Standard Features 18 Programming the Panel 24 R RAM IV 18 24 Related Documentation 10 Remote Account Manager 18 24 Replacing Batteries 26 Reports 24 Transmission 16 17 Watchdog Reset 27 Reset 22 24 30 ...

Отзывы: